Fundamentals of Measurement
A workpiece is considered good only if someone has measured it and can say, with good reason, that its dimensions fall within the tolerances. This chapter opens the section on metrology and lays its foundations: what it means to measure, where confidence in an instrument comes from, what errors are made and how they are reduced, how uncertainty is calculated and reported, when a single measurement is sufficient to accept or reject a workpiece, and why temperature, cleanliness, and the instrument’s position matter just as much as the instrument itself.
31.1 What does it mean to measure?
To measure means compare a quantity with its unit and determine how many times it fits (Chapter 2). In the workshop, it seems like a simple task: you place the caliper against the part and read a number. In reality, there are seven factors behind that number, and each one can introduce an error:
- the quantity being measured: the precise value we wish to determine. “The diameter of the pin” is not enough: in which cross-section? between which points? at what temperature? A slightly oval pin has many different diameters;
- the value: the number you get, which is never the true value, because no one knows the true value; you can only approximate it;
- l'unit: in mechanics, the millimeter and the micrometer (µm), which are always specified;
- the method: the method of measurement (direct, indirect, by comparison, paragraph 31.2) and the written procedure that describes how to perform it;
- the instrument: caliper, micrometer, dial indicator, measuring machine, along with its specifications and calibration status;
- the operator: the person who, through their skill, measures the force applied and interprets the results;
- l'environment: temperature, cleanliness, vibrations, light.
A complete measurement result consists of three parts: value, uncertainty, and unit, for example, 25.012 ± 0.004 mm. The uncertainty (paragraph 31.7) indicates how reliable the value is. A measurement written without an uncertainty is only half the story: “25.012 mm” as read from a vernier caliper and from a coordinate measuring machine does not mean the same thing.
31.2 Direct, Indirect, and Comparative Measurement
The same diameter can be measured in different ways. The method is chosen based on the required accuracy, the number of workpieces, and the available tools.
Direct measurement
The instrument immediately provides the value of the measurement: the vernier caliper, the micrometer, and the ruler. This is the most common method. The instrument’s measuring range must cover the entire dimension; therefore, for a diameter of 80 mm, a micrometer with a range of 75–100 mm is required.
Indirect measurement
Other quantities are measured, and the desired value is calculated using a formula: the diameter of a shuttlecock from its circumference, the mean diameter of a thread using the three-thread method (Chapter 35), an angle using the sine bar (Chapter 33), and a radius from the chord and the arc. Errors in the initial measurements are carried over into the result, magnified or reduced depending on the formula.
A flywheel is too large for any of the workshop's measuring instruments. Using a steel tape wrapped around the rim, the circumference is measured to be C = 1885.0 mm, with a measurement uncertainty of ±0.5 mm. What is the diameter, and what is the uncertainty?
Comparison Measure (Differential)
The instrument does not measure the entire dimension, but only the difference between the workpiece and a known reference sample: a block, a stack of blocks, a ring, or a reference workpiece. The comparator is zeroed against the reference sample, and then the deviation of the workpiece is read. The comparator operates within a range of a few tenths of a millimeter, where it is most accurate, and many errors (temperature, deformation, stand errors) occur equally on both the reference sample and the workpiece and therefore cancel each other out. This is the method used in mass production and metrology laboratories.
The mounted thousandth-of-a-millimeter comparator is zeroed on a stack of blocks measuring 40 + 10 = 50.000 mm. When moved to the workpiece, the pointer reads −7 divisions of 0.001 mm.
A special case of this comparison involves pass/fail gauges (Chapter 14): they do not provide a numerical value, but immediately indicate whether the workpiece is acceptable or must be rejected.
31.3 Traceability and Calibration Chain
Why should we believe what a micrometer tells us? Because someone in a laboratory compared it to a more precise standard; that standard was compared to an even better one, and so on, all the way up to the national standard. This property is called traceability (in English traceability): The result of a measurement is related to the International System of Units through a unbroken chain of calibrations, each with its own stated uncertainty.
- At the top is the definition of the meter: the distance that light travels in a vacuum in 1/299,792,458 of a second. It is not an object, but a definition that anyone can verify with the right instruments.
- In Italy, this is carried out by INRiM (the National Institute of Metrological Research, in Turin) using stabilized lasers and interferometers, which it uses to calibrate the laboratories’ reference sample blocks.
- Accredited calibration centers (accredited in Italy by ACCREDIA and known as LAT centers) calibrate companies' samples and instruments, and issue certificates that are recognized internationally.
- The company stores its reference standards (blocks, rings, swabs, and zeroing rods) and uses them to calibrate its workshop instruments.
- Finally, the machine tool measures the workpiece.
If one link in the chain is missing (a micrometer that has never been calibrated, a gauge with an expired certificate, a sample “we trust”), the measurement is no longer traceable: it may be correct, but no one can prove it to a customer or an inspector. The standards on quality systems (Chapter 38) require precisely this: identified, calibrated, and traceable instruments.
31.4 The Characteristics of an Instrument
In an instrument's catalog and certificate, there are a few terms you should be familiar with, because they don't mean the same thing.
| Feature | What does that mean? | Example |
|---|---|---|
| Measurement range | the range over which the instrument measures | micrometer 25–50 mm; dial indicator 0–10 mm |
| Division Value | the difference between two adjacent marks on the scale | 0.01 mm on the micrometer drum |
| Resolution | the smallest change that the instrument can display; on digital instruments, it is the last digit | 0.01 mm digital caliper; 0.001 mm digital micrometer |
| Sensitivity | how much the reading changes for a unit change in the quantity | comparator: 157 mm dial for 1 mm of travel |
| Linearity | to what extent the response remains proportional across the entire range | error that increases toward full scale |
| Repeatability | How similar are repeated measurements of the same quantity, under the same conditions? | Ten readings that fit within 2 µm |
| Hysteresis | the difference between the reading obtained when approaching from below and the reading obtained when approaching from above | comparator with friction and clearances in the gears |
| Maximum permissible error | the error limit guaranteed by the manufacturer and the calibration check | ±3 µm micrometer across the entire field |
A centesimal comparator makes one full revolution of the pointer for every millimeter of travel; the dial has 100 divisions, and the tip of the pointer traces a circle with a radius of 25 mm.
A comparator is checked every 0.2 mm, first moving up and then down. The errors found, in micrometers, are:
| Position (mm) | 0 | 0,2 | 0,4 | 0,6 | 0,8 | 1,0 |
|---|---|---|---|---|---|---|
| rise (µm) | 0 | 1 | 2 | 2 | 3 | 4 |
| slope (µm) | 2 | 3 | 4 | 3 | 4 | 4 |
| difference (µm) | 2 | 2 | 2 | 1 | 1 | 0 |
31.5 Measurement Errors
Measurement error is the difference between the measured value and the true value. The true value is unknown, but it can be approximated very closely by measuring a calibrated sample, such as a standard block; in that case, the instrument’s error becomes apparent. Errors are divided into three categories, each of which is treated differently.
Gross errors
These are genuine errors: a misread number, an unchecked zero, a vernier scale read at the wrong mark, a chip between the micrometer’s jaws, a workpiece that’s still hot, or a dimension transcribed backward (25.021 instead of 25.012). There are no statistical rules for these: they are avoided through careful attention, cleanliness, method, and repetition. If a reading is significantly different from the others, investigate the cause before using it.
Systematic Errors
They always repeat identically, with the same sign, under the same conditions: a zero point shifted by one micrometer, a steel gauge measuring an aluminum workpiece at 26 °C (Section 31.10), a tilted dial indicator (Section 31.12). Repeating the measurement is pointless, because each reading is off by the same amount. These errors are identified by comparing the instrument with a standard, and when known, they are corrected.
Random errors
They vary from one reading to the next—sometimes a little more, sometimes a little less—and cannot be predicted: small differences in force, position, temperature, dust, and vibrations. They cannot be corrected individually, but they can be reduced by averaging multiple readings and can be estimated using statistics (Section 31.6).
Two words that are often confused:
- Accuracy: how closely repeated measurements resemble one another. It depends on random errors. An accurate measurement yields consistent readings;
- Accuracy: how close the average of the readings is to the true value. It depends primarily on systematic errors. (In the terminology of standards, the closeness of the average to the true value is more precisely called “trueness,” and “accuracy” encompasses both trueness and precision.)
The second point highlighted in the figure is the most dangerous error in the workshop: readings that are all the same may seem reliable, but they are all off by the same amount. Only a sample check can reveal this.
How to Correct Systematic Errors
A sample of known value is measured using the same instrument under the same conditions. The difference between the reading and the sample’s value is the systematic error at that point; the correction is the same number with the sign reversed, and it is added to all subsequent readings.
A 0–25 mm micrometer, placed on a 20.000 mm block, reads 20.003 mm. Immediately afterward, when placed on the workpiece, it reads 18.467 mm.
A correction determined at a single point is reliable only in the immediate vicinity of that point. For an instrument used across the entire measurement range, the complete error curve (as shown in Figure 31.4) is required; this can be found on the calibration certificate.
31.6 Random Errors: Mean and Standard Deviation
When the same measurement is repeated several times, the readings are not all the same. They are expressed as three simple numbers.
Why is s divided by n − 1 rather than by n in the formula? Because the average was calculated from the same readings, which makes them appear slightly more concentrated than they actually are; dividing by n − 1 compensates for this. With many readings, the difference becomes negligible. Scientific calculators have an s (or σn−1) key: that’s the right one.
The diameter of a pin, all in the same section, is measured ten times with a thousandth-millimeter micrometer. The readings are: 25.012 · 25.009 · 25.014 · 25.011 · 25.015 · 25.010 · 25.013 · 25.012 · 25.014 · 25.010 mm. To simplify the calculations and avoid so many zeros, we work in micrometers above 25.000: 12, 9, 14, 11, 15, 10, 13, 12, 14, 10.
The bell curve explains why values are often multiplied by 2 in metrology: approximately 95% of the values fall within ±2s, so a wide interval of ±2s almost always “captures” the correct value. 99.7% fall within ±3s: this is the reasoning we will encounter in statistical process control (Chapter 38).
Using the same micrometer (s = 2 µm), we want an average with a standard deviation of no more than 0.5 µm. How many readings do we need to take?
31.7 Measurement Uncertainty
Uncertainty is an interval around the measured value within which, with a high and specified probability, the true value lies. It is not an error to be corrected: it is the doubt that remains after correcting everything that could be corrected. The method for calculating it is described in an international guide (the GUM, also adopted as a UNI CEI standard); here we’ll look at the simplified version that’s sufficient for use in a workshop.
The Two Approaches: Type A and Type B
- Type A uncertainty: This is calculated using the repeated-measure statistics. It is the standard deviation of the mean, s/√n, as described in paragraph 31.6.
- Type B uncertainty: This is derived from all other factors: the calibration certificate, the maximum permissible error specified by the manufacturer, resolution, knowledge of the temperature, and experience. When it is known only that the error lies within ±a, with no preference for either value, the half-amplitude is divided by √3 (rectangular distribution). If the certificate specifies an expanded uncertainty U with a factor k, it is divided by k.
Resolving Uncertainties: The Sum in Quadrature
The various causes are independent: it is unlikely that they would all be wrong at the same time and in the same direction. For this reason, they are not added directly, but rather by squaring the sum, like the sides of a right triangle: the squares are added, and the square root is taken. The combined uncertainty uc corresponds to one standard deviation, that is, approximately a 68% probability; to obtain approximately a 95% probability, it is multiplied by the coverage factor k = 2, yielding the expanded uncertainty U.
Let’s revisit the ten readings from Example 31.6, taken with a 25–50 mm micrometer with a resolution of 0.001 mm. The manufacturer specifies a maximum permissible error of ±3 µm; the parallelism of the measuring faces is guaranteed to be within ±1 µm; the workpiece and the micrometer, both made of steel, may differ in temperature by up to 2 °C.
| Reason | Type | Calculation | u (µm) | u² (µm²) |
|---|---|---|---|---|
| repeatability of readings | A | 2,0 / √10 | 0,63 | 0,400 |
| 1 µm resolution | B | 1 / (2 · √3) | 0,29 | 0,083 |
| micrometer error ±3 µm | B | 3 / √3 | 1,73 | 3,000 |
| Face parallelism ±1 µm | B | 1 / √3 | 0,58 | 0,333 |
| temperature: 11.5 × 10⁻⁶ × 25 × 2 = 0.58 µm | B | 0,575 / √3 | 0,33 | 0,110 |
| sum of squares | 3,927 |
The factor that weighs most heavily is the instrument’s error: it alone accounts for three-quarters of the total. Taking 100 readings instead of 10 would make almost no difference; to improve the result, we would need a better micrometer or a comparative measurement using blocks.
How to Write a Result
- "uncertainty" is spelled with one or, at most, two significant digits, rounded by excess (it's better to be a little more uncertain than the opposite);
- The value is rounded to the same decimal place as the uncertainty: it makes no sense to write 25.01237 if the uncertainty is 4 thousandths;
- The unit and the coverage factor are always specified: 25.012 ± 0.004 mm (k = 2).
A spreadsheet returns a value of 12.34567 mm and an expanded uncertainty of 0.01231 mm.
31.8 The Rule of Tithing and the Choice of Instrument
Before taking a measurement, you should ask yourself whether the instrument is suitable for the tolerance. The most widely used rule of thumb is the one-tenth rule: the measurement uncertainty (and therefore also the instrument’s resolution) must not exceed one-tenth of the tolerance to be checked.
If this rule cannot be followed (for example, for tolerances of a few micrometers), a ratio of 1/5 to 1/4 is acceptable; however, in that case, the uncertainty significantly reduces the useful tolerance range, as shown in paragraph 31.9. The table provides approximate values for instruments in good condition, used by an experienced operator in a typical workshop environment; the actual values can be found on the certificates.
| Tool | Resolution (mm) | Typical uncertainty (mm) | Minimum tolerance using the one-tenth rule (mm) |
|---|---|---|---|
| Vernier Caliper | 0,02 o 0,05 | from 0.03 to 0.05 | from 0.3 to 0.5 |
| Digital Caliper | 0,01 | from 0.02 to 0.03 | from 0.2 to 0.3 |
| Centesimal Micrometer | 0,01 | from 0.005 to 0.01 | from 0.05 to 0.1 |
| Millesimal Micrometer | 0,001 | from 0.002 to 0.004 | from 0.02 to 0.04 |
| Centesimal comparator (for comparison) | 0,01 | from 0.005 to 0.01 | from 0.05 to 0.1 |
| Thousandth-of-an-inch comparator on blocks | 0,001 | from 0.001 to 0.002 | from 0.01 to 0.02 |
| Electronic comparator in the metrology lab | 0,0001 | from 0.0003 to 0.0005 | from 0.003 to 0.005 |
| Coordinate measuring machine (Chapter 37) | 0,0001 | from 0.002 to 0.005 | from 0.02 to 0.05 |
Approximate and rounded values: The actual uncertainty depends on the model, dimensions, method, and environment.
A shaft with a diameter of Ø40 and a height of h7 has a tolerance of IT7 = 25 µm (Chapter 14): from 39.975 to 40.000 mm.
According to its certificate, a digital caliper has an uncertainty of 0.02 mm. What dimensions can it measure while adhering to the rule of tenths?
31.9 Determining Whether a Workpiece Meets Specifications: The Zones in ISO 14253-1
A workpiece measures 25.018 mm; the tolerance is up to 25.020 mm; the uncertainty is 0.004 mm. Is it acceptable? It’s hard to say: the true value could be 25.014 (good) or 25.022 (out of tolerance). The ISO 14253-1 standard specifies how to make this determination while taking uncertainty into account, and divides the scale into zones.
- Conformance zone: the narrow tolerance of uncertainty U on either side. A measurement within this zone proves that the workpiece is in conformance.
- Nonconforming zone: outside the expanded tolerance of U on either side. A measurement here indicates that the workpiece is nonconforming.
- Areas of uncertainty (doubtful): the two 2U-wide bands straddling each limit. Here, the measurement does not prove either one or the other.
The rule is based on a common-sense principle: the party that must prove something bears the burden of uncertainty. The supplier who wants to prove that the workpiece is acceptable uses the narrow zone; the customer who wants to prove that the workpiece should be rejected must find it outside the expanded zone. In borderline zones, the decision is based on an agreement between the parties, or the part is remeasured using a more precise method (smaller U, narrower borderline zones).
Tolerance 25 ± 0.020 mm (LSL = 24.980, USL = 25.020), uncertainty U = 0.004 mm. Three pins were measured: 25.012, 25.018, and 25.026 mm.
Note that here U = 0.004 mm with a tolerance of T = 0.040 mm: this is exactly the one-tenth rule, yet the compliance zone is already 20% narrower than specified in the drawing (32 µm instead of 40). With a 1/4 ratio, half of the tolerance would be lost.
31.10 Reference Temperature and Expansion
All materials expand when heated (Chapter 14, Hot Assembly). For this reason, a dimension is meaningful only if the temperature at which it applies is specified. ISO 1 sets the reference temperature at 20 °C: the dimensions in the drawing, the tolerances, and the measurements of blocks and tools are all valid at 20 °C.
| Material | α (10⁻⁶ /°C) | Material | α (10⁻⁶ /°C) |
|---|---|---|---|
| Carbon steel, steel blocks | 11,5 | Aluminum and Alloys | 23 |
| Gray cast iron | 10 | Brass | 19 |
| Austenitic stainless steel | 16 | Copper | 17 |
| Titanium | 8,6 | Granite (countertops) | 6 to 8 |
| Hard metal | 5 to 6 | Engineering plastics (POM, PA) | from 80 to 120 |
Average values are rounded and approximate; actual alloys may vary.
The workpiece and the instrument expand together
If the workpiece and the measuring tool are made of the same material and are at the same temperature, they expand by the same percentage, and the reading remains accurate even at temperatures other than 20 °C: this is why micrometers, calipers, and gauge blocks are made of steel, just like most workpieces. Problems arise when:
- the workpiece is made of a different material (aluminum, brass, plastic) and the measurement is not taken at 20 °C;
- The workpiece and the tool are at different temperatures: the workpiece has just come out of the machine, while the tool has been warmed by hands or the sun.
When the temperatures are the same but the materials are different, the length at 20 °C is calculated as follows:
In a room at 26 °C, a workpiece of aluminum left for a long time next to the instrument (and therefore at the same temperature) is measured with a steel micrometer: 200.020 mm. What is its measurement at 20 °C? (αs = 11.5 × 10⁻⁶, αp = 23 × 10⁻⁶ /°C)
A Ø100 steel shaft comes off the lathe at 30 °C and is immediately measured with a micrometer that has been stored in a cabinet at 20 °C.
Stabilization time and hand temperature
A workpiece brought into the metrology lab must remain on the work surface until it reaches room temperature. The time required depends on the mass and material: from a few tens of minutes for a small piece of aluminum to many hours for a steel block weighing tens of kilograms. A reliable rule of thumb is to place it on a cast-iron or granite surface (which acts as a thermal mass) and take a measurement when two readings taken 15 minutes apart yield the same value.
The operator’s body is also a source of heat: the hands are over 30 °C. Holding a block, a zeroing rod, or the jaw of a large micrometer stretches them by a few micrometers in just a few minutes. This is why micrometers have insulating plates on the jaw, collets are used to handle blocks, and small workpieces are placed gently rather than held tightly.
A 100-mm steel block, when held in the hand for a couple of minutes, heats up by 2 °C.
31.11 Abbe's Error
Ernst Abbe, a 19th-century German physicist, formulated the principle that bears his name: the instrument’s scale must lie on the same line as the dimension to be measured. If there is a distance h between the scale line and the measurement line, any slight tilt of the cursor (due to clearances, wear, or the operator’s force) results in an error proportional to h.
The slide of a caliper is 40 mm long and has a clearance of 0.02 mm at the scale. A workpiece is measured at the end of the jaws, at h = 30 mm from the scale, and then near the scale, at h = 10 mm.
The micrometer, on the other hand, follows Abbe’s principle: the micrometer screw, which serves as its scale, lies on the same axis as the anvil and the rod. An inclination of the rod no longer results in an error proportional to the inclination, but only in a very small cosine error (Section 31.12). This is one of the reasons why the micrometer is more precise than the vernier caliper, in addition to its higher resolution.
Suppose that the stem of a micrometer, which is 25 mm long, is tilted by the same angle as the gauge (tan θ = 0.0005). The error is now given by cosine: L · (1 − cos θ).
12/31 Parallax, Measurement Force, Cosine, and Positioning
Parallax error
In analog instruments, the indicator (the pointer, the edge of the vernier scale, or the line on the drum) does not lie exactly on the plane of the scale, but slightly above it, at a distance g. If the eye is not looking perpendicular to the scale, the indicator will appear to point to a different mark. Solution: Always read with your eye aligned perpendicular to the pointer; some comparators have a small mirror on the dial, and the reading is correct when the pointer covers its reflected image. Digital instruments do not have parallax.
Measuring Force and Deformation
To take a measurement, you must touch the workpiece, and touching means applying pressure. The measuring force elastically compresses the contact point, bends the micrometer’s arc, and, on thin workpieces, deforms the workpiece itself. To keep it constant, the micrometer has a clutch (or ratchet) on the drum, which always slips at the same force, usually between 5 and 10 N; dial indicators have a spring that pushes the stem with 1 or 2 N. The rule is: turn only the clutch, never the drum while holding it between your fingers.
When a spherical tip presses against a flat surface, the contact is not a point but a small elastic indentation, and the tip “sinks” by a distance δ, which is estimated using Hertz’s theory:
Spherical steel tip, Ø3 (R = 1.5 mm), measuring force 1.5 N, on a steel workpiece and then on an aluminum workpiece.
These are small numbers, but when compared to steel blocks, the difference (0.23 µm) on an aluminum workpiece is no longer negligible. With double the force, the compression increases by a factor of 22/3 = 1.59. On thin-walled tubes, spring rings, and plastics, the deformation of the workpiece is much greater: in these cases, reduced forces or non-contact tools are used (Chapter 37).
Cosine Error of the Comparator
The stylus of a dial indicator must move in the same direction as the displacement being measured—that is, perpendicular to the surface. If it is tilted by an angle α, the stylus must travel a greater distance—d / cos α—to track a displacement d of the surface; the reading is greater than the actual value. The same thing happens with a lever-type comparator (dial indicator) when the arm is not parallel to the surface.
When checking the eccentricity of a shaft, the dial indicator is tilted 15° and reads 0.250 mm.
Positioning Errors
The instrument must touch the workpiece at the correct points. An outside diameter measured with the micrometer tilted appears larger than it actually is; a hole measured with the tips offset from the center yields a chord that is shorter than the diameter. For this reason, the instrument is oscillated within the hole to find the maximum value, while on a shaft or between two flat surfaces, the minimum value is sought. Bore gauges (Chapter 32) have centering supports specifically for this purpose.
A Ø50 hole (R = 25 mm) is measured with the probes offset by e = 1 mm from the center.
31.13 Cleaning, reference surface, and metrology room
Cleaning and Deburring
A strand of hair is about 0.05 mm thick, a film of oil is a few micrometers thick, and a speck of dust is 1 to 10 µm in size. These quantities are all comparable to the tolerances. Before taking any measurement:
- Clean the measuring faces of the instrument (by placing a sheet of clean paper between the faces of the micrometer and pulling it out smoothly) and the surfaces of the workpiece;
- Remove the coolant and chips, including those inside the holes and threads;
- Remove any burrs: a burr on an edge can lift the workpiece off the surface or keep the jaws of the micrometer open, and the measurement will then reflect the size of the burr. Workpieces with burrs cannot be measured.
The reference plane
The reference surface is the surface on which the workpieces, the blocks, and the dial indicator stand rest. It is made of two materials:
- granite (actually often diabase or black gabbro): it does not rust, is not magnetized, expands very little, remains stable over time, and, when struck, chips without raising a bump. It is the most commonly used material in metrology laboratories;
- Stabilized and scraped cast iron: more impact-resistant, suitable for workshop use and marking, but it must be protected from rust.
The floors are constructed of flatness classes (00, 0, 1, 2, 3 according to DIN 876, or the equivalent classes in ISO 8512): Classes 00 and 0 have deviations of only a few micrometers even on surfaces one meter in length and are intended for metrology laboratories; Classes 1 and 2 are suitable for workshop inspections; Class 3 is for marking out. The exact value depends on the dimensions and is specified on the surface’s certificate. The surface rests on three supports Adjustable, because three points always define a plane and the slab does not warp; it should be checked periodically because it wears down more in the area where work is always being done.
The Metrology Lab
The most precise measurements are taken in a dedicated room—the metrology lab—under controlled conditions. Approximate values:
| Condition | Typical value | Why |
|---|---|---|
| Temperature | 20 °C ± 1 °C (± 0.5 °C for more precise measurements) | ISO 1 reference, controlled expansion |
| Change over time | less than 1 °C per hour | The workpieces and instruments keep up in time |
| The Difference Between High and Low | less than 1 °C per meter | The workpiece must not have any part that is hotter |
| Relative humidity | 40 to 60 percent | No rust on the instruments, no condensation |
| Vibrations | low; floors and machines on isolated bases | Micrometer readings must not waver |
| Cleanliness and Light | filtered dust, even lighting without direct sunlight | dust on their faces, parallax, the heat from the lamps |
Even those who work in a workshop can follow these guidelines: keep tools away from windows, radiators, and engines; make sure workpieces are securely positioned on the working plane; and do not leave the micrometer on the machine in direct sunlight.
31.14 Calibration, Certificates, and Instrument Management
Three words not to confuse:
- calibration: the comparison of an instrument with a traceable standard to determine its errors and uncertainty. Calibration does not “adjust” anything; it measures and documents;
- adjustment (or calibration): the process of bringing the instrument closer to the correct setting, such as resetting the micrometer to zero using the adjustment screw. After an adjustment, the calibration must be repeated;
- verification (or metrological confirmation): the comparison of calibration results with the limits established by the company, which leads to a decision: whether the instrument should be used, used with restrictions, or taken out of service.
The Calibration Certificate
A reliable certificate must include at least the following: the instrument’s identification (brand, model, serial number, or internal code), the date, environmental conditions, the samples used along with their traceability, the method, the results item by item (sample value, reading, error), and the expanded uncertainty with its coverage factor. Certificates from accredited centers bear the ACCREDIA mark and the center’s LAT number. The certificate does not state that the “instrument is good”; this is determined by the company by comparing errors and uncertainty with its own standards, using the same reasoning as in ISO 14253-1.
The company accepts a maximum error of ±2 µm for micrometers ranging from 0 to 25 mm. The certificate specifies, with U = 0.6 µm (k = 2), an error of +1.2 µm at 10 mm and +1.7 µm at 20 mm.
Calibration Intervals
There is no legally mandated calibration interval that applies to everyone: the company determines the interval based on how often the instrument is used, the environment, the required accuracy, and the history of previous calibrations (if the instrument is well within the limits each time, the interval can be extended; if it is out of range, the interval is shortened, and the workpieces measured in the meantime are evaluated). Indicative starting values:
| Tool | Approximate range |
|---|---|
| Calipers and Micrometers for Everyday Use in Manufacturing | 6 to 12 months |
| Comparators and Bore Gauges | 12 months |
| Pass/Fail Gauges (plugs, forks, rings) | 3 to 12 months, depending on the number of workpieces inspected |
| Workshop Reference Blocks | 1 to 2 years |
| Sample blocks from the metrology lab | 2 to 3 years |
| Reference planes | 1 to 3 years |
Between calibrations, interim checks are performed: the micrometer is zeroed daily or at the start of each shift, and a check is performed on a calibration block if the instrument falls or gives unusual readings.
Status Labels
Each instrument has a unique code (engraved or on a tag) and a label that shows at a glance whether it can be used. The most common colors are as follows:
An instrument that has expired, is unlabeled, or has been dropped must not be used to measure workpieces until it has been rechecked. If calibration reveals that it was out of tolerance, you must determine which workpieces were measured with it since the last successful calibration: this is why the instrument log must be kept up to date (Chapter 38).
Management and Conservation
| To Do | Don't Do This |
|---|---|
| Put each instrument back in its case, clean | Leave it on the machine among the chips and coolant |
| Protect the steel parts with a thin layer of light oil or an anti-corrosion product | Touching the measuring surfaces with sweaty fingers |
| Store the micrometer with the jaws slightly open | Close it tightly: the faces get damaged and the bow remains taut |
| Slowly bring the instrument closer and use the clutch | Using a caliper as a hammer, compass, or wrench |
| Remove the batteries from digital devices that have not been used for a long time | Measuring a rotating workpiece or one that is still hot |
| Report a fallen tool immediately | Put it back in the drawer, hoping it hasn't gotten ruined |
| Keep reference samples separate from test samples | Do not bring steel tools near magnets or magnetic spindles |
31.15 The Formulas in This Chapter
| What Are You Looking For? | Formula | Units |
|---|---|---|
| Comparison Measure | dimension = sample + reading | mm |
| Systematic Error and Correction | E = xread − xsample · C = −E | mm |
| Media | x̄ = (x1 + … + xn) / n | mm |
| Standard Deviation | s = √(Σ vi² / (n − 1)) | mm or µm |
| Standard Deviation of the Mean (Type A) | sx̄ = s / √n | mm or µm |
| Rectangular Type B | u = a / √3 | mm or µm |
| Type B from the resolution | u = r / (2 · √3) = 0,29 · r | mm or µm |
| Type B as indicated on the certificate | u = U / k | mm or µm |
| Composite Uncertainty | uc = √(u1² + u2² + …) | mm or µm |
| Widespread Uncertainty | U = k · uc (k = 2) | mm or µm |
| Rule of Tenths | U ≤ T / 10 · r ≤ T / 10 | mm |
| Compliance Zone (ISO 14253-1) | from LSL + U to USL − U | mm |
| Non-Compliance Zone | below LSL − U or above USL + U | mm |
| Dilation | ΔL = α · L · (t − 20) | mm |
| Measurement taken at 20 °C | L20 ≈ Lletta + L · (αs − αp) · (t − 20) | mm |
| Abbe's Error | e = h · tan θ | mm |
| Parallax error | e = g · tan β | mm |
| Flattening a sphere on a plane | δ = ∛(9 · F² / (16 · R · E*²)) | mm |
| Cosine Error | true = reading · cos α · error = reading · (1 − cos α) | mm |
| Chord of an off-center hole | chord = 2 · √(R² − e²) | mm |
31.16 Exercises
Try to solve them on your own, using a calculator, before looking at the solution.
Solution
30.000 + 0.018 = 30.018 mm; 30.000 − 0.006 = 29.994 mm.
Solution
D = 2513.3 / 3.1416 = 800.0 mm.
Solution
In µm, above 48,000: 12, 15, 10, 13, 16; sum 66, average 13.2 µm → 48.0132 mm. Deviations: −1.2; +1.8; −3.2; −0.2; +2.8; squares: 1.44 + 3.24 + 10.24 + 0.04 + 7.84 = 22.8 µm². s = √(22.8 / 4) = √5.7 = 2.39 µm; s / √5 = 2.39 / 2.236 = 1.07 µm.
Solution
uc = √(1.44 + 0.64 + 0.25) = √2.33 = 1.53 µm; U = 2 × 1.53 = 3.05 µm, rounded up to 3.1 µm.
Solution
U ≤ 0.030 / 10 = 0.003 mm = 3 µm. A digital caliper (U ≈ 0.02 mm) won't work: you need a thousandth-millimeter bore gauge zeroed to a reference ring, or a pass/fail plug gauge.
Solution
Compliant from 49.958 to 50.042; non-compliance below 49.942 or above 50.058. 50.030: compliant. 50.046: questionable (between 50.042 and 50.058). 49.940: non-compliant (below 49.942).
Solution
Correction = 150 · (11.5 − 19) · 10⁻⁶ · 5 = −0.0056 mm; L20 = 150.012 − 0.0056 = 150.0064 mm.
Solution
e = 25 · tan 0.03° = 25 · 0.000524 = 0.0131 mm, approximately 13 µm.
Solution
true = 0.050 · cos 20° = 0.050 · 0.9397 = 0.0470 mm.
Solution
cord = 2 · √(40² − 0.5²) = 2 · √1599.75 = 79.9937 mm; error 80 − 79.9937 = 0.0063 mm, approximately 6 µm.
Solution
u = 0.01 / (2 · √3) = 0.01 / 3.464 = 0.0029 mm.
Solution
δ increases as F²/³: 0.40 · 22/3 = 0.40 · 1.587 = 0.63 µm.
Solution
√n ≥ 3 / 1 = 3 → n ≥ 9 readings.
