Actuators and Servo Drives
A sensor tells the machine what’s happening; an actuator is the part that makes things happen: it moves the table, closes the collet, opens the valve, and heats the oven. In this chapter, we’ll look at the different types of actuators and, above all, how they’re controlled: the difference between open-loop and closed-loop systems, a straightforward explanation of the PID controller, and the servo drive of a CNC axis with its three loops, the tracking error, and the Kv gain. Finally, we’ll size a real axis—the same one used in the milling machine from Chapter 40—and discuss safety and alarms.
48.1 Actuators and the drive train
An actuator is a device that receives a command and converts it into a physical action: a movement, a force, an opening, or the emission of heat. The command almost always arrives as a weak signal (a few volts, a few milliamps, a message on a fieldbus) that, on its own, could not move anything. Between the control unit and the actuator, there is therefore a drive: a device that draws power from the electrical grid, compressed air, or pressurized oil and regulates it according to the command. An electric servo drive regulates current, while a valve regulates air or oil.
Actuators are classified based on the type of energy they use:
- rotary electric motors: DC motors, asynchronous motors with inverters, brushless motors, and stepper motors (Chapter 45); when combined with a screw, a belt, or a rack (Chapter 40), they also produce linear motion;
- linear electric actuators: linear motors, which directly drive the carriage without a lead screw, and electromagnets (solenoids), which have travels of a few millimeters;
- pneumatic systems: cylinders and compressed-air motors (Chapter 42); simple, fast, and economical, but air is compressible, and it is difficult to stop precisely halfway through the travel;
- hydraulics: hydraulic cylinders and motors (Chapter 43); enormous forces in a small space, with high rigidity because oil is virtually incompressible;
- piezoelectric materials: crystals or ceramics that stretch very slightly when a voltage is applied; their travels are measured in micrometers, but they generate high forces and have response times of milliseconds.
| Actuator | Force or Torque | Speed | Positioning Accuracy | Cost | Typical Uses |
|---|---|---|---|---|---|
| Servomotor + Recirculating Screw | medium-high (up to tens of kN) | high (30–60 m/min) | very high (micrometers) | mid-to-high | CNC axes, electric presses |
| Linear motor | medium (up to a few kN continuous) | very high (over 100 m/min) | very high (less than a micrometer) | high | lasers, grinding, high-dynamic axes |
| Step-by-Step | low | low-medium | good, as long as she doesn't lose her footing | low | 3D printers, small axes, dispensers |
| Pneumatic Cylinder | low to medium (a few kN at 6 bar) | high | low: usually just the two limit switches | low | collets, pushers, locks |
| Hydraulic cylinder | very high (hundreds of kN) | average | good with a servo valve | high | presses, bending machines, clamping devices |
| Electromagnet | low (from a few N to a few hundred) | very high (milliseconds) | none: all or nothing | very low | solenoid valves, brakes, locks |
| Piezoelectric | high, but on micrometer-scale travels | very high | nanometers | high | micro-positioning, high-speed valves |
Guideline table: The categories overlap, and each manufacturer has products that fall outside these ranges.
A pneumatic cylinder has a bore of 50 mm and a piston rod of 20 mm, and is pressurized to 6 bar. What is the force it exerts during extension and retraction, neglecting friction? (The cylinder is discussed in Chapter 42.)
A 20-mm-long "stack-type" piezoelectric actuator stretches, at maximum voltage, by 0.15% of its length (approximate value). How much does it move?
48.2 Electromagnets and Solenoid Valves
The simplest actuator of all is theelectromagnet: a coil of copper wire wound around an iron core. When current flows through the coil, a magnetic field is generated in the iron (Chapter 44) that attracts a moving part, the core o still. When the current is turned off, a spring pulls the core back. The air gap between the stationary and moving parts is called air gap: That's where the power is concentrated.
The faces of the core and the fixed pole have an area of 4 cm². When the core is nearly closed, the magnetic flux density in the air gap is 1 T. What is the resulting force? And what if the wider air gap reduces B to 0.5 T?
The solenoid valve: an electromagnet that controls a fluid
In pneumatics and hydraulics, the electromagnet acts as the “motor” for solenoid valves (Chapters 42 and 43): the core moves the valve spool or spool, and the valve directs the air or oil to one chamber or the other of the cylinder. The PLC controls the coil (usually 24 V DC), the coil controls the valve, and the valve controls the cylinder: this is a drive chain like the one shown in Figure 48.1, where a small electrical signal controls a force of thousands of newtons.
- Monostable: one coil and one spring; when de-energized, the valve always returns to the same position. This is the right choice when, in the absence of power, the machine must move to a safe position.
- Bistable: two coils, no spring; a pulse to one coil moves the valve, which remains in that position until a pulse is applied to the other coil. When the power is off, the cylinder remains in its current position.
- Proportional solenoid valve: The current in the coil is not simply on or off but is modulated, causing the valve to open more or less. This is the first step toward the servo valves described in section 48.12.
Electromagnets are also found in motor brakes, electromagnetic clutches, and car door locks: the door remains locked as long as the spindle is turning (paragraph 48.13).
48.3 Open loop and closed loop
There are two ways to control an actuator. In the open-loop control The controller sends the command and trusts that it will be executed; it does not verify the result. In the closed-loop control (or in feedback) A sensor measures the result; the control system compares it with the desired value and adjusts the command until the difference is eliminated.
Everyday examples help. A timer-controlled toaster is an open-loop system: it heats for two minutes and doesn’t know whether the bread is golden brown or burnt. An oven with a thermostat is a closed-loop system: it measures the temperature and turns the heating element on or off. Driving a car is a closed-loop system in which the eyes act as the sensor and the brain acts as the controller: if the car drifts toward the edge of the road, the steering is corrected. Driving with your eyes closed, counting the seconds, is an open-loop system.
Here are the names of the blocks, which apply to any closed-loop system, from a thermostat to the axis of a milling machine:
- reference (or desired value, setpoint) r: what we want, for example, dimension X50 or a temperature of 60 °C;
- output (or controlled variable) y: the actual value—the table position or the oven temperature;
- error e = r − y: the difference between the desired value and the actual value; it is this that “drives” the entire loop;
- controller: the “brain” that calculates, based on the errors, the command u to be sent to the actuator;
- actuator and process: the motor with its lead screw and table, the resistor with the oven;
- sensor: measures the output (encoder, optical encoder, thermocouple: Chapter 47) and closes the loop;
- disorders d: the shear force that slows down the table, the oven door open. The great advantage of the closed-loop system is that it also corrects disturbances that no one had anticipated.
A small axis has a stepper motor rated at 200 steps per revolution with a driver that divides each step into 10 microsteps (Chapter 45), and a lead screw with a pitch of 5 mm. What is its resolution? How many pulses are needed for 30 mm? If the motor loses 40 microsteps due to a shock, what happens?
| Open Ring | Closed ring |
|---|---|
| Simple and inexpensive, no sensor | You need a sensor and a controller |
| He doesn't notice the problems or the errors | corrects malfunctions, friction, and variable loads |
| always stable | If the regulator is calibrated incorrectly, it may fluctuate |
| It works when the load is known and constant | Essential when precision and safety are required |
| toaster, timer, simple step-by-step instructions | thermostat, cruise control, CNC axes, robot |
48.4 Two-position control with hysteresis
The simplest controller has only two outputs: on or off. This is called on/off or two-position control. It’s the type used in home thermostats, refrigerators, and air compressors, which restart when the pressure drops and stop when it rises.
If the thermostat turned on and off exactly at 60 °C—turning on just below 60 and turning off just above it—the relay would trip dozens of times per second, and it would wear out in a matter of hours. That’s why hysteresis is used—a dead band around the desired value: it turns on when the temperature drops below the lower limit, turns off when it exceeds the upper limit, and nothing changes in between. The wider the band, the fewer times the relay switches, but the more the temperature fluctuates.
An oven must maintain a temperature of 60 °C with a hysteresis of ± 2 °C. When the heating element is on, the temperature rises by 0.5 °C/s; when it is off, it drops by 0.25 °C/s. How long does a cycle last? What fraction of the time is the heating element on?
On/off control works just fine when a few degrees or a few tenths of a bar more or less don't matter. It’s not suitable for an axis: a table that moves forward at full speed and then backward at full speed around a given dimension would never come to a stop. In that case, you need a controller that modulates the command continuously—that is, the PID controller described in the following paragraphs.
48.5 How to Evaluate a Control: The Response to a Step Change
To determine whether a closed-loop system is functioning properly, a simple test is performed: the reference is suddenly changed (by one step), and the output response is recorded. This is also done in the workshop during the commissioning of an axis: a small displacement is commanded, and the waveform on the drive software’s oscilloscope is observed.
- Overstretching (overshoot): the amount by which the tool extends beyond the final dimension, expressed as a percentage. On an axis, this means that the tool goes beyond the dimension and then retracts; on a shoulder, it leaves a mark.
- Rise time: how long it takes for the output to approach its final value (usually from 10% to 90%). It indicates how “ready” the loop is.
- Settling time: the time it takes for the output to settle within a range around the final value (±2% or ±5%) and remain there.
- Steady-state error: the difference between the reference value and the output when everything has come to a stop. On a single axis, this must be zero, or a few micrometers.
Many real-world systems (an axis with its mass and elasticity, a suspension, an instrument needle) behave like a second-order system, whose response depends primarily on a single parameter, the damping coefficient ζ (zeta): When ζ is small, the response oscillates significantly; when ζ = 1, it reaches the final value without exceeding it.
The piston of a hydraulic press with position control receives a command to move from 0 to 50.0 mm. The piston reaches a maximum of 53.1 mm, then stops at 45.0 mm. Calculate the steady-state error, over-extension, and equivalent damping.
48.6 The PID Controller
The most widely used controller in industry is called PID, which stands for the initials of its three components: proportional, integral, and derivative. Each component evaluates the error in a different way, and the control signal sent to the actuator is the sum of the three. To understand this, let’s think about how we adjust the shower: we look at how far the water is from the right temperature (present), how long it has been off (past), and whether it’s changing quickly (future).
The proportional term (P): responding to the present
The control signal is proportional to the error: u = Kp · e. A large error results in a large control signal; a small error results in a small control signal. Kp is the proportional gain. The drawback of using only P control is that, in processes requiring a constant control signal to maintain steady-state operation (an oven needs power to stay hot, a vertical screw needs torque to support the weight), there is always an error at steady state: if the error were zero, the control signal would be zero, and the oven would cool down. Increasing Kp reduces the error, but the response becomes erratic and ultimately unstable.
An oven must reach a temperature 180 °C above room temperature. At steady state, each 1% of heating element power corresponds to a 2 °C temperature overshoot (K = 2 °C/%). With a proportional-only controller, what is the remaining error when Kp = 5 %/°C? And when Kp = 20 %/°C?
The Integral Term (I): Remembering the Past
The integral term accumulates the error over time: as long as there is even a small error, the sum grows, and the control signal grows with it. It stops only when the error is exactly zero. It is this term that eliminates the error at steady state: at steady state, the error is zero, and the control signal needed to keep the oven warm is provided by the accumulated sum. The trade-off is a bit of slowness and a greater tendency to oscillate, because the integral “remembers” the error even after the output has already passed the setpoint. This is adjusted using the integral time Ti: the shorter it is, the stronger the integral action.
The Derivative Term (D): Looking to the Future
The derivative term measures how quickly the error changes. If the output is approaching the setpoint very quickly, the D term reduces the control signal in advance, much like braking before reaching a stop sign. It dampens runouts and reduces overshoot. Its drawback is that it amplifies sensor noise: a “jittery” signal has a very high derivative. For this reason, the D term is used with a filter, and in many control loops (such as slow temperature loops), it is set to zero. It is adjusted using the derivative time constant Td.
An oven controller has Kp = 2 %/°C, Ki = 1 %/(°C · s), and Kd = 0.5 %·s/°C. At a certain moment, the error is 3 °C, the sum of the errors over time is 10 °C·s, and the error is decreasing by 0.4 °C per second. What power does it control?
| If you increase | Readiness | Overstretching | Steady-State Error | Stability |
|---|---|---|---|---|
| Kp | improve | grows | It decreases, but it does not disappear | worsens |
| full-length (shorter Ti) | get a little better | grows | is canceled | worsens |
| the derivative action (longer Td) | little effect | cala | no effect | It improves if the signal isn't noisy |
Guideline table: This applies to common cases; every case has its own surprises.
48.7 Empirical Calibration
Tuning a PID controller means choosing Kp, Ti e Td. This can be done through calculations, based on a process model, but in the workshop it’s almost always done by trial and error. Modern temperature controllers and drives have a function to autocalibration (car tuning): They run a few tests on the process themselves and propose the parameters. It's still a good idea to know how to do it manually.
The Manual Procedure
- Start with just P, with Kp set low, the integral term turned off (Ti at maximum), and the derivative term set to zero;
- Increase Kp in small increments, taking one small step at a time, until the response begins to overshoot too much; then go back a little;
- The integral is introduced by shortening Ti until the steady-state error disappears within an acceptable time, without long-term runouts;
- If necessary, add a little derivative to dampen the overstretch, making sure the control doesn't become "jittery."
The Ziegler-Nichols Method
A classic method, developed in the 1940s, provides a starting point using a single test: using only P, Kp is increased until the output oscillates constantly, without damping and without increasing. That gain is called the critical gain Ku, and the period of the runouts is called the critical period Tu. The parameters are obtained from the table. The test pushes the system to the limit of stability: it should only be performed where a runout is not dangerous (never on an axis with a workpiece mounted and the tool nearby).
In the process shown in Figures 48.7 and 48.8, Kp is increased until steady-state runouts are observed: this occurs when Ku = 12.6, and the runouts have a period of Tu = 1.52 s. Calculate the PID parameters.
48.8 The Servo Drive of a CNC Axis: The Three Loops
An axis of a CNC machine is the most important example of a closed-loop system in a machine shop. However, there is not just one loop: there are three, nested one inside the other (cascaded control). Each loop controls a variable and provides a reference to the innermost loop.
- Current loop (the innermost and fastest): In a brushless motor, torque is proportional to current (Chapter 45). The drive measures the current in the phases and regulates it using a PI controller, driving the inverter transistors with PWM modulation. Regulating the current means regulating the torque.
- Speed loop: It compares the setpoint speed with the speed measured by the motor encoder and requests more or less torque from the current loop. It is usually a PI controller: the integral term is used to maintain the speed even when the cutting force slows down the table.
- Position loop (the outermost one): compares the requested dimension, updated by the CN at each interpolation cycle, with the measured dimension, and instructs the speed loop to set a speed proportional to the error. It is usually a simple P controller, with gain Kv (paragraph 48.10).
Why three loops and not just one? Because each inner loop “handles” the fastest-changing problems before they reach the outer loop: the current loop compensates for the motor’s inductance and voltage fluctuations, the speed loop compensates for friction and shear forces, and the position loop receives an axis that is already responding well. The rule is that each inner loop must be much faster than the external one, at least three to five times as much. That is why the tuning is done from the inside out: first current, then speed, then position.
| Ring | Regulator | Calculation Period | Readiness |
|---|---|---|---|
| Current (torque) | PI | 50 to 125 µs | 1–3 kHz bandwidth |
| Speed | PI (with filters) | 100 to 250 µs | 100–400 Hz bandwidth |
| Location | P (+ feed-forward) | from 0.25 to 2 ms | Kv from 20 to 100 1/s |
Approximate values for modern machine tool drives; these depend heavily on the manufacturer and the mechanical design. The “bandwidth” indicates the maximum frequency at which the ring can track the reference signal.
48.9 Semi-closed loop and closed loop
The position that enters the position ring can be measured at two different points, and the difference is important for the machine's accuracy.
- Semi-closed-loop system: The position is derived from the encoder mounted on the motor by counting the revolutions and multiplying by the lead of the lead screw. This is the most common and economical solution. However, the controller measures the rotation of the motor, not the position of the table: everything between the motor and the table (coupling, pitch errors, lead screw clearance, thermal expansion of the lead screw) is not accounted for by the loop and can only be compensated for using tables (pitch and clearance compensation, Chapter 50).
- Closed ring (or “direct reading”): the reading is taken from a optical line (Chapter 47) mounted between the bench and the table. Now, the screw, clearances, and expansion are inside the ring: If the screw expands as it heats up, the ruler detects it and the control system makes the necessary correction. Speed continues to be derived from the motor's encoder.
During a long machining operation, the screw on an axis heats up by 5 °C. The working dimension is 500 mm from the fixed bearing. The coefficient of thermal expansion of steel is 12 × 10−6 1/°C (approximate value). By how much does the semi-closed-loop axis deviate? And in a closed-loop system?
An axis with a 10-mm-pitch lead screw, connected directly to the motor, has a 22-bit absolute encoder. What is its resolution? Compare it to the 2,500-pulse-per-4 encoder in Example 40.21.
48.10 Tracking Error and Kv Gain
The position loop of an axis is almost always a proportional controller: the speed commanded to the motor is proportional to the position error. This leads to a consequence that surprises those who see it for the first time: A moving axis is always behind schedule compared to the dimension specified by the CN. If the error were zero, the commanded speed would be zero and the axis would stop. To move at a speed v The axis must have an error such that Kv · e = v. This delay is called tracking error (The following error, regarding Siemens controls, also “tracking deviation”).
An axis has a Kv of 2 (m/min)/mm. What is this value in 1/s? What is its tracking error at F1200 (1200 mm/min)?
The same type of axis, with Kv = 30 1/s, moves at rapid feed rate at 30 m/min. What is its tracking error? The manufacturer sets the “excessive tracking error” alarm threshold to about 20% above the normal value: what is that value?
Why Tracking Error Matters: Interpolation
In a single-axis movement, the tracking error leaves no trace on the workpiece: the axis still reaches the dimension, just a moment later. The problem arises when two axes move together. On a line inclined at 45°, the X and Y axes have the same speed: if they have the same Kv, they have the same error, and the tool remains on the line, just slightly behind. If the Kv values are different, one axis lags behind the other, and the tool strays from the path. For this reason, the interpolating axes must have the same Kv value, and the manufacturer sets it to the same value for all axes, using the value of the “slower” axis.
In circular interpolation, even with Kv Under these conditions, the delay causes the tool to “cut the curve short”: the actual circle ends up slightly smaller than the programmed one. With Kv When the angle changes, it becomes an ellipse tilted at 45°. This can be clearly seen with the rim test (ballbar, Chapter 37).
A hole with a radius of 10 mm is milled using circular interpolation (G02) at F2000 on a machine with Kv = 30 1/s and without feed-forward. By how much does the radius decrease? What about with a radius of 50 mm? And with Kv = 60 1/s?
Feed-forward (overview)
The CN knows the trajectory in advance: it already knows what speed will be needed in the next instant. Instead of waiting for an error to occur, it can send the required speed directly to the speed loop, adding it to the position controller’s output. This is feed-forward control: the position loop need only correct the small portion that the feed-forward did not anticipate. With 100% speed feed-forward, the tracking error at constant speed disappears almost entirely; acceleration feed-forward is often added as well, which sends the torque in advance to accelerate the masses. On Fanuc, it is activated with high-precision contouring control (G05.1 Q1, already mentioned in Chapter 9); on Siemens, with FFWON.
The axis in Example 48.12 (e = 0.6 mm at F1200) receives an 80% speed feed-forward. What is the remaining tracking error?
48.11 Axle Sizing
When selecting a motor for an axis, you need to check three things: that it provides enough torque for acceleration and operation, that it can reach the rapid traverse speed, and that the ratio of inertia between the load and the motor is reasonable. In addition, you should verify that the resolution is sufficient, which is almost always the case with modern encoders.
The inertia transmitted to the engine
The motor must accelerate not only its own rotor, but also everything attached to it. To perform the calculations, everything is considered as being “on the motor shaft,” converting the translational masses and the slower-rotating inertia into an equivalent inertia. There are two rules:
- A mass m moved by a screw with pitch P has, as viewed from the screw, J = m · (P / 2π)² (Example 40.22): the pitch divided by 2π is the “arm” of the screw;
- inertia J that's going around i slower than the engine, via a gearbox or a belt with a reduction ratio i, that is, as seen from the engine, J / i². It comes from kinetic energy: ½ · J · (ω/i)² = ½ · (J/i²) · ω².
The Ratio of Inertia
The ratio of inertias λ = Jload / Jm It indicates how much the load “weighs” relative to the rotor. If λ is large, the motor is like a small horse pulling a heavy cart: in theory, the torque is sufficient, but any slight flexibility in the coupling, screw, or belt causes the motor and load to no longer move together, and the speed loop detects a load that “bounces.” You have to lower the gain, and the axis becomes slow and imprecise, or it vibrates. As a (rough) rule of thumb, λ is kept below 5 for machine tool axes that must be precise and dynamic; up to 10 They are acceptable for less demanding axes with very rigid mechanics, but beyond that, special measures are required. “Medium-inertia” servo motors are specifically designed for machine tool axes.
A rotary table carrying the workpiece has a moment of inertia of 2 kg·m². It is driven by a worm gear with a gear ratio of 90 and an efficiency of 0.6 (approximate value). It must accelerate from rest to 30 rpm in 0.2 s. What is the inertia experienced by the motor, and what torque is required to accelerate the table alone? The motor’s rotor has 1.5 × 10−4 kg·m².
Let’s revisit the setup from Example 40.22: a table with a 300-kg workpiece on roller guides (μ = 0.01), a milling feed force of 1500 N, lead screw with a pitch of 10 mm, Ø32 × 1000 mm, efficiency 0.9, connected to the motor via a coupling. Rapid traverse at 3000 rpm (30 m/min), reached in 0.1 s. A brushless servomotor with the following (approximate) catalog specifications is being tested: continuous torque 6 N·m, maximum torque 18 N·m, 3000 rpm, rotor inertia 8.0 × 10−4 kg·m², 20-bit encoder. The coupling has 1.0 × 10−4 kg·m². Check the torque, moment of inertia ratio, speed, and resolution.
We want to install a heavy workpiece on the same machine: the moving mass increases to 1,500 kg. What is the inertia ratio with the same motor? What are the possible solutions?
48.12 Direct-drive systems, robots, and servo valves
Linear Motors
A linear motor is an “unrolled” brushless motor: the part with the coils (the primary) is attached to the carriage, while the part with the permanent magnets (the secondary) is stretched out along the table. The force is generated directly between the two parts, without screws, belts, or couplings. There is no clearance, no mechanical wear, and the axis can reach accelerations of 1–2 g and speeds of over 100 m/min (approximate values). On the other hand, linear motors generate a lot of heat (liquid cooling is required), attract metal chips with their magnets, cost more, and—since there is no reduction gear— the load and disturbances are all transmitted to the motor: λ no longer exists, and very fast encoders and very fine optical scales are required. On vertical axes, there is neither a non-reversible lead screw nor a brake on the screw; brakes on the guides and balancing systems are required.
The 300-kg table in Example 48.17 is moved by a linear motor with an acceleration of 10 m/s² (approximately 1 g). What force is required to accelerate it? And what if it is accelerated while the milling machine is operating at 1,500 N?
Torque motors on rotary tables
The same principle of rotation is utilized by the torque motor: a brushless motor with many poles, a large diameter, and a short length, mounted directly beneath the rotary table’s platter. It delivers torque in the hundreds or thousands of N·m at low speeds, without a worm gear, without clearance, and without wear. It is the solution for the rotary tables and tilting tables of the most dynamic five-axis machining centers.
The 2 kg·m² table in Example 48.16 is driven by a torque motor and must accelerate from a standstill to 100 rpm in 0.2 s. What torque is required?
Servo Motors for Robotics
Each joint of an industrial robot has a brushless servomotor, almost always equipped with a compact, high-ratio gearbox (epicyclic, cycloidal, or deformation wave, the so-called Harmonic Drive, Chapter 40), an absolute encoder, and a brake. The three rings are the same as those on the CNC axis, but the load perceived by each motor changes continuously with the position of the arm: the robot controller calculates the inertia and torques due to the weight at every instant and sends them via feedforward to the drives. Robotics is covered in Chapter 51.
Position-controlled hydraulic servo valves and actuators
A hydraulic cylinder can function as a precision axis if it is equipped with a high-quality servo valve or proportional valve (Chapter 43) and a position transducer (often magnetostrictive, mounted inside the rod). The principle is the same: the controller compares the position with the reference and controls the valve’s flow, which regulates the oil flow to the cylinder. It is used where enormous forces are required with good precision: presses, press brakes with crossbeam parallelism controlled by two cylinders, test benches, and flight simulators.
48.13 Drive Safety: STO and Brake
A servo drive can move an axis with forces of thousands of newtons in a few hundredths of a second. When an operator opens the door or presses the emergency stop button, it must be ensured that the drive cannot start moving. In the past, a large contactor was used to disconnect the power supply from the drive; today, almost all drives have a built-in safety feature called STO (Safe Torque Off).
- With the STO active, the drive removes the control signals from the transistors of the inverter via a hardware circuit that is independent of the software: the motor receives no power and cannot produce torque.
- The STO is controlled using two channels separate, so that a single failure (a broken wire, a stuck relay) cannot prevent the stop; the drive checks that the two channels are consistent.
- The STO does not apply the brakes: the motor continues to rotate freely until the masses come to a stop due to friction. For this reason, the axis is usually braked first using the control system (controlled stop), and then the STO is activated: the categories of stops and the relevant standards are described in Chapter 51.
- The STO does not remove the voltage: hundreds of volts remain on the capacitors inside the drive. To work on the cables, you must disconnect them and wait for the charge to dissipate, as indicated on the drive.
Brakes on the vertical axes: why
A ball screw is so efficient that it is reversible (Chapter 40): a load pushing the nut causes the screw to rotate. On the Z-axis of a milling machine, on the column of a machining center, or on the vertical axis of a gantry, the spindle slide weighs hundreds of kilograms. As long as the drive is active, the motor holds the slide in place with its torque. But if the power fails, if the STO trips, or if the drive fails, the torque disappears and the slide would drop, dragging the screw with it, until it crashes into the workpiece or the table. For this reason, the motors on the vertical axes have a spring-loaded parking brake: the spring keeps it engaged, and only the current in a coil releases it. When the power is off, the brake engages automatically.
The parking brake is not a service brake: it is designed to hold the axis in place, not to stop it while it is moving (it only does so in an emergency, which causes it to wear out). It should be tested regularly: many vehicles perform a brake test automatically, requesting torque from the engine with the brake engaged and checking that the axis does not move.
The vertical slide with the spindle has a mass of 250 kg; the lead screw has a pitch of 10 mm and an efficiency of 0.9; there is no counterbalance. What torque does the weight exert on the lead screw? What torque must the motor provide to climb at a constant speed? What type of brake should be selected, with a safety factor of 2?
In addition to STO, modern drives offer other built-in safety functions: SS1 (safe stop—first brakes, then removes torque), SLS (safe speed limit, for example, with the door open in commissioning mode), and SBC (safe brake control). We’ll cover these along with the safety standards in Chapter 51.
48.14 Commissioning, Alarms, and Vibrations
Commissioning an axis is the process by which the machine manufacturer or service technician teaches the drive how the axis works. In order:
- Set the motor and encoder parameters (which are often automatically read from the motor's electronic nameplate), the lead screw pitch, and the reduction ratio;
- Check the directions: a positive command must move the axis in the positive direction, and the encoder must also count in the positive direction;
- The loop tests are performed from the inside out: current, speed, position. Many drives measure the load inertia on their own and suggest the gain settings;
- Determine the mechanical resonances by measuring the frequency and set the filters;
- Set the acceleration, jerk, feed-forward, and Kv values to be the same for the interpolating axes, and then set the tracking error thresholds;
- Adjustments are made (lead, clearances, deflection), and the system is verified using the ring test or a laser interferometer (Chapter 37).
Common Alarms
| Alarm | What does that mean? | Common Causes |
|---|---|---|
| Excessive tracking error (while moving) | The axis fell short of the threshold | impact, seized axis, brake that won't release, unlubricated guides, excessive acceleration, insufficient torque |
| Excessive tracking error (at rest) | the stationary axis has moved more than the threshold | load pushing, brake slipping, vertical axis lowering, encoder malfunctioning |
| Overcurrent | The current exceeded the inverter's limit | short circuit in the cable or motor, insulation damaged by oil and coolant, gain set too high, transistor failure |
| Overload (I²t) | The engine has been operating for too long at continuous torque. | Excessively heavy-duty machining operations, increased friction, damaged screws or guides, cycle with too many accelerations |
| Motor or drive overheating | The temperature sensor has exceeded the limit | overload, fans not running, or clogged filters in the cabinet; high ambient temperature |
| Intermediate Circuit Overvoltage | When braking, the motor feeds energy back into the system, causing the internal voltage to rise too high | Brake resistor faulty or disconnected; heavy loads braking too abruptly |
| Encoder error | The position signal is missing or inconsistent | Damaged cable or wet connector, broken shielding, faulty encoder |
Every manufacturer has its own alarm codes: their exact meanings are listed in the machine's alarm manual.
Axis Vibrations and Filters (Overview)
The mechanics of an axis are not rigid: the coupling, lead screw, nut, bearings, and the table itself are all springs with their own masses, and they have resonance frequencies (Chapter 9), often ranging from a few tens to a few hundreds of hertz. If the speed ring is fast enough to “excite” one of these frequencies, the axis whistles or hums while at a standstill, and regular marks remain on the surface of the workpiece. Remedies, in order of preference:
- make the mechanism stiffer (stiffer joint, larger-diameter screw, preloaded bearings, reinforced strut) or lighter;
- Insert a band-reject filter (notch), which removes the resonance frequency—as measured by the drive's frequency analysis—from the control signal;
- Use a low-pass filter on the torque reference to remove high frequencies;
- As a last resort, lower the gain: the axis stops vibrating but becomes less precise, with a lower Kv and larger shape errors.
Then there are low-frequency vibrations affecting the entire machine, which occur when an accelerating axis causes the column or workpiece to “sway”: these are countered by limiting jerk (Chapter 9) and by applying filters to the motion profile calculated by the CNC. On a simulator like CNC Code, these phenomena don’t cause any damage, making it the ideal place to observe the effect of feeds and rapid movements on cycle times before testing on the actual machine.
48.15 The Formulas in This Chapter
| What | Formula |
|---|---|
| Force of an Electromagnet | F = B² · A / (2 · μ₀), μ₀ = 4π · 10−7 H/m |
| Error | e = r − y |
| Steady-state error with only P | e∞ = r / (1 + K · Kp) |
| Overstrain (second order) | Mp = e^(−π·ζ)/√(1−ζ²) · ζ = −ln Mp / √(π² + ln² Mp) |
| PID Controller | u = Kp · e + Ki · ∫e dt + Kd · de/dt · Ki = Kp / Ti · Kd = Kp · Td |
| Ziegler-Nichols (PID) | Kp = 0,6 · Ku · Ti = Tu / 2 · Td = Tu / 8 |
| Tracking error | e = v / Kv · e [mm] = v [mm/min] / (60 · Kv [1/s]) = v [m/min] / Kv [(m/min)/mm] |
| Kv Conversion | 1 (m/min)/mm = 16.67 1/s |
| Radius error in a circle | Δr ≈ v² / (2 · Kv² · r) |
| Inertia of the table as seen from the screw | Jtav = m · (P / 2π)² |
| Inertia through a gearbox | J' = J / i² |
| Total Inertia | Jtot = Jm + Jg + (Jv + Jtav) / i² |
| Engine torque | M = (Jm + Jg) · α + Jload · α / η + (Fatt + Flav) · P / (2π · η · i) · α = ω / ta |
| Ratio of Inertia | λ = Jload / Jm, typically less than 5 (at most 10) |
| Axis Speed and Resolution | v = n · P / i · resolution = P / (Ninc · i) |
| A Successful Couple | Meff = √(Σ Mk² · tk / Σ tk) |
| Linear motor | F = m · a + Fatt + Flav |
| Vertical axis | Mtrasc = m · g · P · η / (2π) · Msalita = m · g · P / (2π · η) |
48.16 Exercises
Try to solve these problems on your own, using a calculator, before looking at the solution. Unless otherwise specified, g = 9.81 m/s², and the values in the table are approximate.
Solution
F = 0,8² · 6 · 10−4 / (2 · 1,257 · 10−6) = 3,84 · 10−4 / 2,513 · 10−6 = 153 N.
Solution
1 °C range. On: 1 / 0.3 = 3.33 min; off: 1 / 0.2 = 5 min; period 8.33 min (about 7 cycles per hour); on 3.33 / 8.33 = 40% of the time.
Solution
K · Kp = 12; e∞ = 100 / 13 = 7.7 units; the output stops at 92.3.
Solution
ζ = 0,7: Mp = e−π · 0,7 / √0,51 = e−3,079 = 0,046 = 4,6%. ζ = 0,3: Mp = e−π · 0,3 / √0,91 = e−0,988 = 0,372 = 37%.
Solution
Kp = 0,6 · 12 = 7,2; Ti = 0,8 / 2 = 0,4 s; Td = 0,8 / 8 = 0,1 s.
Solution
Kv = 40 / 16.67 = 2.4 (m/min)/mm. v = 1500 / 60 = 25 mm/s → e = 25 / 40 = 0.625 mm (or 1.5 / 2.4 = 0.625 mm).
Solution
e = 24 / 1.5 = 16 mm; the 20-mm threshold is 25% higher: that's fine.
Solution
v = 3000 / 60 = 50 mm/s; Δr = 50² / (2 · 40² · 20) = 2500 / 64,000 = 0.039 mm.
Solution
ΔL = 12 · 10−6 · 8 · 800 = 0.077 mm; with an optical ruler, the error would be corrected by the ring.
Solution
J = 500 · (0,016 / 6,2832)² = 500 · 6,485 · 10−6 = 3,24 · 10−3 kg·m².
Solution
Direct: λ = 3.0 / 0.5 = 6, too high. With the belt: Jload = 3,0 · 10−3 / 2,5² = 4,8 · 10−4 kg·m² → λ = 0.96.
Solution
ω = 2000 · 2π / 60 = 209.4 rad/s; α = 209.4 / 0.05 = 4189 rad/s²; M = 1,2 · 10−3 · 4189 = 5,03 N·m.
Solution
217 = 131,072 increments per revolution; resolution = 5 / 131,072 = 3.8 × 10−5 mm = 0.038 µm.
Solution
F = 200 · 15 + 0,01 · 200 · 9,81 = 3000 + 19,6 = 3020 N.
Solution
Weight 180 · 9.81 = 1,765.8 N. Mtransc = 1765,8 · 0,005 · 0,9 / 6,2832 = 1,26 N·m; Mascent = 1765.8 × 0.005 / (6.2832 × 0.9) = 1.56 N·m; a braking force of at least 2 × 1.26 = 2.5 N·m (for example, 3 N·m).