Electric Motors and Inverters
Behind every movement of a machine tool is an electric motor: the spindle, the axes, the coolant pump, and the tool changer. In this chapter, we’ll explore how motors work, starting with the force that a magnetic field exerts on a current-carrying wire: the DC motor, the three-phase induction motor with its nameplate and starting methods, the inverter that varies its speed, the brushless and stepper motors used in the axes, and the electric spindles. Finally, we’ll learn how to select a motor for a given load and keep it in good working order. The basic electrical quantities (voltage, current, three-phase, cos φ) are covered in Chapter 44.
45.1 The Principle: Force on a Conductor and Torque
All electric motors, from a small fan to a 30-kW electric spindle, are based on an experimental fact: a conductor through which current flows, when placed in a magnetic field, is acted upon by a force. The force is perpendicular to both the conductor and the field lines, and it increases as the field strength increases, as the current increases, and as the length of the conductor segment within the field increases.
The magnetic field and its measurement are introduced in Chapter 44. Its strength is measured by the magnetic induction B, in tesla (T). To give you an idea: a refrigerator magnet measures a few hundredths of a tesla, while the air gap of an industrial motor measures between about 0.6 and 1 T.
From Force to Torque
A straight conductor pushed on one side does not cause anything to rotate. However, if we bend the wire into a coil and mount it on a shaft, current flows through the two sides of the coil in opposite directions: one is pushed upward, the other downward. The two forces, equal and opposite, at a distance r from the axis, form a torque (Chapter 2) that causes the coil to rotate. With N turns, the torque is multiplied by N. The rotor of a real motor has dozens of conductors, arranged in the slots of a cylinder made of steel laminations that concentrates the magnetic field.
A 0.25 m-long conductor in a magnetic field with B = 0.8 T carries a current of 20 A. What force does it experience? What torque does a coil with 50 turns exert when its sides are 0.05 m from the axis?
The principle is reversible
The reverse is also true: if a conductor moves within a magnetic field, a voltage is induced at its ends (this is the law of electromagnetic induction). Any motor that is driven from the outside becomes a generator. We will see this in DC motors, in braking with an inverter, and in generators.
45.2 The Direct Current Motor
It is the easiest motor to understand and adjust, and for many years it was the motor used in the axes and spindles of CNC machines. Today, it is still found in small battery-powered drives, windshield wipers, hand tools, and older machines.
- Stator: the stationary part. It generates the magnetic field using permanent magnets or excitation windings through which direct current flows, wound around the poles.
- Rotor (or armature): the rotating stack of laminations with conductors in the slots.
- Commutator: a cylinder consisting of copper segments that are insulated from one another and connected to the rotor windings.
- Brushes: graphite blocks pressed against the commutator by springs, which carry current to the rotor. As the rotor turns, the commutator reverses the current in the coils as they pass from one pole to the next, so that the torque always points in the same direction.
Speed proportional to voltage, torque proportional to current
When the rotor rotates, its conductors move through the magnetic field and generate a voltage opposite to that of the supply voltage: the counter-electromotive force E, which is proportional to the speed. A small portion of the applied voltage V is used to overcome the resistance of the windings, and the rest is used to “balance out” E. This leads to two rules that make DC motors so convenient:
- The speed is almost proportional to the applied voltage;
- The torque is proportional to the current drawn (at constant field strength).
A 220 V DC motor with a rotor resistance of 0.8 Ω draws 15 A and runs at 1,500 rpm. What is the value of the counter-electromotive force? At what speed will it run, with the same load (same current), if we power it at 110 V?
For the same motor, calculate the constant K, the torque at 15 A and 30 A, and the current if we were to connect it to 220 V while it is at a standstill.
Adjustment
To change the speed of a DC motor, simply change the field voltage—today using an electronic converter (and in the past, using resistors or a motor-generator unit). Conversely, lowering the excitation current weakens the magnetic field, causing the motor to run faster but with less torque: this is demagnetization, a phenomenon we’ll find in inverters as well, beyond the base frequency. The weak point is the commutator: the brushes and commutator segments wear out, produce sparks and dust, and limit the maximum speed. For this reason, in new machines, the DC motor has been replaced by the asynchronous motor with an inverter and by the brushless motor.
45.3 The Three-Phase Induction Motor: Rotating Field and Slip
The three-phase asynchronous (or induction) motor is the most widely used motor in the world: it drives pumps, compressors, fans, conveyor belts, and—when used with a variable-frequency drive—many spindles as well. It is robust, economical, and virtually maintenance-free, since it has neither a commutator nor brushes.
The rotating magnetic field
The stator contains three identical windings, spaced 120° apart, powered by the three phases of the power grid, which are 120° out of phase with each other (Chapter 44). Each one on its own would produce a field that pulses back and forth along its axis. When combined, the three fields produce a field of constant intensity that rotates, as if an invisible magnet were rotating inside the stator. No part moves: it is the alternating currents that cause the field to rotate.
Synchronization Speed
With a two-pole winding (a single pole pair, one north and one south), the field makes one complete revolution per period of the current: at 50 Hz, it makes 50 revolutions per second, or 3,000 revolutions per minute. With four poles (two pairs), the field makes half a revolution per period, and so on. The speed of the field is called the synchronous speed.
| Poli | Polar pairs p | n₀ at 50 Hz (rpm) | n₀ at 60 Hz (rpm) | Typical speed for 50 Hz nameplate ratings |
|---|---|---|---|---|
| 2 | 1 | 3000 | 3600 | 2850-2950 |
| 4 | 2 | 1500 | 1800 | 1420-1480 |
| 6 | 3 | 1000 | 1200 | 940-980 |
| 8 | 4 | 750 | 900 | 700-735 |
Approximate RPMs: Smaller engines run at higher RPMs, while larger ones run at lower RPMs.
Calculate n0 for a 4-pole motor at 50 Hz and 60 Hz (a machine imported from the United States), and for a 6-pole motor at 50 Hz.
Why “asynchronous”: scrolling
As the rotating field turns, it “cuts” through the rotor conductors and induces currents in them (which is why the motor is also called an induction motor). The rotor currents, immersed in the field, experience the force shown in Figure 45.1, and the rotor begins to rotate in pursuit of the field. But it never catches up: if it were to rotate at the same speed, the conductors would no longer see the field moving, the induced currents would disappear, and with them, the torque. The rotor always lags slightly behind, and this difference is called slip. The more load is applied to the motor, the more the rotor slows down and the greater the slip becomes, until the required torque is achieved.
A 4-pole motor operating at 50 Hz under full load rotates at 1,440 rpm. Calculate the slip and the frequency of the currents in the rotor.
The nameplate on a 50 Hz motor says 965 rpm; another says 2,920 rpm. How many poles do they have, and what is their current?
The squirrel-cage rotor
The most common type of rotor is the squirrel-cage rotor: inside the slots of the laminated core are die-cast aluminum bars (or copper bars, in high-efficiency motors), all short-circuited by two rings at the ends. There are no wires to connect and no sliding contacts: the rotor receives power solely by induction, through the air gap. The bars are slightly angled relative to the axis to make the torque smoother and the motor quieter.
There is also the wound rotor, which has three windings connected to rings and brushes, allowing for the insertion of starting resistors: it was used in cranes and large machines, but today it has almost always been replaced by inverters.
A Note on Single-Phase Motors
With a single phase (230 V household power), the magnetic field does not rotate: it merely pulses, and the motor does not start on its own when at a standstill. Single-phase induction motors therefore have a second winding, connected via a capacitor that shifts the phase of its current and creates an imperfect rotating magnetic field. Often there is a larger starting capacitor, which a centrifugal switch or a relay disconnects once the motor has reached operating speed. They are used for applications up to 2–3 kW: small drill presses, bench grinders, pumps, and household compressors. They have lower starting torque and efficiency than three-phase motors. To reverse the direction of rotation, the connections of the auxiliary winding are swapped.
45.4 The Nameplate of the Induction Motor
Each motor has a nameplate with the information needed to connect it, protect it, and select the right inverter. The nameplate specifications are the rated values: the operating conditions under which the motor can run indefinitely without overheating. Let’s take as an example a 7.5 kW, 4-pole motor, which is very common in compressors, pumps, and older lathes.
| License Plate Information | What does that mean? |
|---|---|
| 3~, type 132M-4 | Three-phase motor. This model features a standard shaft height (132 mm from the base to the shaft), a medium-sized housing (M), and 4 poles. |
| 7.5 kW | Output power: the mechanical power available at the shaft, not the power drawn from the grid. On older motors, it is listed in CV (Chapter 2). |
| 230 V Δ / 400 V Y | Voltage: Each winding is rated for 230 V. On a 400 V power supply, the motor is connected in a star (Y) configuration between phases; on a 230 V power supply, it is connected in a delta (Δ) configuration between phases. We will examine the terminal block in section 45.6. |
| 50 Hz | Rated frequency; many motors also list specifications at 60 Hz. |
| 25,4 A / 14,6 A | Rated current for the 230 V delta connection and the 400 V star connection: this is the value used to calibrate the thermal relay and the inverter. |
| cos φ 0.82 | Power factor at full load (Chapter 44): A portion of the current is used to magnetize the motor and does not produce work. At no load, the power factor (cos φ) drops significantly, even below 0.2. |
| 1455 min⁻¹ | Rated speed at full load, in revolutions per minute (min⁻¹ is the same as rpm). From this, the number of poles and the slip are determined: 4 poles, s = 3%. |
| IE3 90.4% | Efficiency class according to IEC 60034-30-1 and full-load efficiency: of the kW drawn from the grid, 90.4% is transferred to the shaft. |
| S1 | Service: S1 refers to continuous service, with a constant load for an unlimited period of time. Other duty cycles: S2 is short-duration (e.g., S2 30 min), S3 is intermittent, and S6 involves alternating load and no-load periods (e.g., S6 40%: in each 10-minute cycle, 4 minutes under load and 6 minutes no-load). In S6, a motor can deliver more power than in S1. |
| IP55 | Protection rating: The first digit (5) indicates protection against dust and solid objects; the second digit (5) indicates protection against water (jets from any direction). The higher the numbers, the better protected the motor is. |
| Insulation Class F | Winding insulation class: Class F withstands temperatures up to 155 °C. Class F motors are typically designed to operate at temperatures similar to those of Class B motors (130 °C), with a margin that extends their service life. |
| Cushion 6308-2Z / 6208-2Z | The shaft-side and fan-side bearings (Chapter 39), which are useful for maintenance. |
Using the data from the nameplate shown in Figure 45.6, recalculate the current at 400 V and 230 V, the power consumption, and the losses.
Nominal torque
The torque figure isn't listed on the license plate, but it can be calculated immediately from the power and RPM using the formula in Chapter 2.
Yield and IE Classes
An electric motor loses energy in the windings (Joule effect), in the laminated steel core, in the bearings, and in the fan. The IEC 60034-30-1 standard classifies motors into efficiency classes: IE1 (standard), IE2 (high), IE3 (premium), and IE4 (super premium). In the European Union, starting in 2021, new three-phase motors ranging from 0.75 to 1000 kW must meet at least the IE3 efficiency standard. To increase efficiency, manufacturers use more copper, higher-quality laminations, copper bars in the cage, and more efficient fans.
| Class (7.5 kW motor, 4-pole, 50 Hz) | Minimum yield | Power Consumption (kW) | Losses (kW) |
|---|---|---|---|
| IE1 | 87,0% | 8,62 | 1,12 |
| IE2 | 88,7% | 8,46 | 0,96 |
| IE3 | 90,4% | 8,30 | 0,80 |
| IE4 | 92,6% | 8,10 | 0,60 |
Approximate values, rounded; for other engines, refer to the table in the standard.
A compressor operates 4,000 hours per year at full load with a 7.5 kW IE2 motor. How much can be saved by replacing it with an IE4 motor, assuming electricity costs 0.25 € per kWh?
45.5 The Torque-Speed Curve and Inrush Current
The behavior of an induction motor can be determined from its torque-speed curve (see Chapter 7 for information on reading the diagrams). Starting from a standstill:
- At zero speed, the motor delivers a starting torque Ms, which is usually 1.8 to 2.5 times the rated torque;
- As the speed increases, the torque may drop slightly (the “dip”), then rise to the maximum torque Mmax, which is 2.5 to 3.5 times the rated torque;
- After reaching its peak, the curve drops sharply and flattens out at synchronous speed. In this nearly straight section, the motor operates as follows: with each increase in load, it slows down slightly and delivers more torque. The rated point is here.
The motor stops at the point where its torque equals the load's resistance torque. As long as the motor's torque curve remains above that of the load, the difference accelerates the machine. If the load exceeds the maximum torque, the motor suddenly slows down until it stops and draws a very high current; this is called stalling.
Inrush current
When at a standstill, the rotor behaves like the short-circuited secondary winding of a transformer: the slip is 1, the induced currents are enormous, and the motor draws an inrush current from the grid that is 5 to 8 times the rated current. This lasts only a short time (from a fraction of a second to a few seconds, depending on the load’s inertia), but it causes the line voltage to drop, puts stress on the contactors, and trips protective devices set too low. In catalogs, it is listed as the Is/In ratio, along with Ms/Mn and Mmax/Mn.
The catalog for the 7.5 kW motor states the following values on the nameplate: Is/In = 7, Ms/Mn = 2.3, Mmax/Mn = 2.9. Calculate the values at 400 V.
45.6 Starting, Reversing, and Protection
Direct Startup
The simplest way is to connect the motor to the power supply using a contactor (a coil-operated switch; see Chapter 44). The motor starts with its full starting torque and full starting current. This is suitable for small and medium-sized motors, provided the line can handle the peak current and the motor can withstand the inrush; the limits are determined by the power distributor and the system designer.
The Terminal Block: Star and Delta
The six leads from the three windings connect to the terminal block: U1-U2, V1-V2, W1-W2. Using terminal blocks, they are connected in a star configuration (the three leads U2, V2, and W2 connected together) or in a delta configuration (each winding connected between two phases). The staggered arrangement of the lower terminals (W2, U2, V2) is specifically designed to form a delta connection using three straight connectors.
The star-delta starter
A motor operating in delta configuration on the power grid (for example, a 400 V Δ / 690 V Y motor on a 400 V grid) can be started in star configuration and then switched to delta. In star configuration, each winding receives √3 times less voltage; the current in each winding decreases by a factor of √3, and the line current—which in delta configuration was √3 times the phase current—decreases by a total factor of 3. Torque is proportional to the square of the voltage, so it also decreases by a factor of 3.
The circuit uses three contactors: KM1 for the line, KM3 to close the star connection, and KM2 to form the delta connection. At startup, KM1 and KM3 are closed; after a few seconds, when the motor is close to operating speed, a timer opens KM3 and closes KM2. KM2 and KM3 must never be closed simultaneously (interlock). During the switching operation, there is a brief current spike, which is lower than that of a direct-on-line start.
A 7.5 kW motor, 400 V Δ, with In = 14.6 A and the same gear ratios as in Example 45.10, drives a fan that requires less than 10 N·m at startup, or a loaded belt that requires 45 N·m right from a standstill. What are the starting current and starting torque in a star connection? In what cases is this suitable?
The soft starter
A soft starter is an electronic device that uses thyristors to modulate the voltage: at startup, the motor receives a reduced voltage, which gradually increases until it reaches line voltage. A current limit can be set. The current decreases in proportion to the voltage, while the torque decreases with the square of the voltage. Compared to star-delta starting, it produces no voltage spikes during commutation and is also used for smooth stopping (e.g., pumps, to prevent water hammer). However, it does not change the operating speed; for that, a variable-frequency drive (VFD) is required.
The motor itself starts up using a soft starter, which initially supplies 60% of the voltage. What are the starting current and torque values?
Reversal of the direction of rotation
To make an induction motor run in reverse, all you have to do is switch two phases Any: The rotating field changes direction, and the rotor follows it. If the motor needs to rotate in both directions during operation, two contactors are used: KM1 connects the phases in the normal order, while KM2 connects them with two phases swapped. The two contactors have a interlock electrical and mechanical, because if they were closed together, they would cause a short circuit between two phases.
Protection Using a Thermal Relay
An overloaded motor draws more current than normal, heats up, and, after a few minutes or a few hours, burns out the insulation on the windings. The thermal relay (or motor protection device, if combined with a magnetic short-circuit breaker) monitors the current in all three phases and, if it remains above the set value for too long, opens the contactor’s control circuit. It is intentionally delayed to allow the inrush current to pass. It also trips if a phase is missing, a condition in which the motor continues to run and overheats significantly.
- It is calibrated at the rated current at the connection voltage, which must not be higher;
- In a star-delta connection, the relay is usually connected to the phases of the windings, which carry the phase current; therefore, it is set to In / √3;
- In motors with inverters, the inverter provides thermal protection; it monitors the current, which we set in the parameters. Many motors also have sensors (PTCs) in their windings.
A motor with a rated current of 14.6 A is started using a star-delta method, with the thermal relay connected to the windings. What value should it be set to? And what if the relay were connected to the line, upstream of everything?
45.7 The Inverter: How It's Made
The formula n0 = 60 · f / p states that to change the speed of an induction motor, you must change the frequency. This is what an inverter—also known as a frequency variator or frequency converter—does: it takes the fixed-frequency mains supply and provides the motor with a three-phase voltage whose frequency and voltage are adjustable, for example from 0 to 100 Hz.
There are three stages inside:
- the rectifier, a diode bridge that converts the alternating current from the power grid into direct current;
- the continuous-current bus (intermediate circuit), with large capacitors that smooth out the voltage and act as an energy reservoir;
- The inverter bridge consists of six IGBT transistor-based electronic switches that, by turning on and off thousands of times per second, connect each phase of the motor to the + or − terminal of the bus and generate an alternating voltage at the desired frequency.
A microprocessor-based control board controls the IGBTs, measures the motor currents, reads commands (start, stop, speed) from terminals, a keypad, or the field network, and protects the motor and inverter from overloads, overvoltages, and short circuits.
PWM Modulation
IGBTs operate only as switches—either fully on or fully off—because this minimizes heat dissipation. To obtain a “sinusoidal” voltage, one uses the pulse-width modulation (PWM, pulse width modulation): Each stage is connected to the + and − terminals of the bus using very rapid pulses (the switching frequency, from 2 to 16 kHz). Where a high voltage is needed, the positive pulses are wide; where a low voltage is needed, they are narrow. The motor windings, which have inductance, “smooth out” the pulses, and the resulting current is nearly sinusoidal.
Calculate the bus voltage of a three-phase 400-V inverter and a small single-phase 230-V inverter.
45.8 V/f Control: Constant Torque and Constant Power
The magnetic field in the motor depends on the ratio of voltage to frequency. If we were to lower only the frequency while keeping the voltage at 400 V, the iron core would become saturated and the magnetizing current would rise to the point of burning out the motor; if we were to lower the voltage too much, the field would weaken and the torque would decrease. The simplest method, V/f control (or scalar control), keeps the voltage-to-frequency ratio constant: for a 400-volt, 50-hertz motor, the ratio is 400 / 50 = 8 volts per hertz.
- Below the base frequency (the rated frequency, 50 Hz), the voltage increases in proportion to the frequency; the magnetic field remains at its rated value, and the motor can deliver its rated torque at all speeds: this is the constant-torque zone. Power increases with speed. At very low frequencies, a small amount of voltage (the boost) is added to compensate for the voltage drop across the winding resistance.
- Above the base frequency, the inverter cannot output more than the line voltage: the voltage remains constant at 400 V, the V/f ratio decreases, and the magnetic field weakens (de-fluxing). The available torque decreases in inverse proportion to the frequency, while the power remains at the rated value: this is the constant-power zone.
The 7.5 kW, 4-pole motor, operating at 1,455 rpm at 50 Hz, is controlled by a V/f inverter. Calculate the voltage, speed, torque, and power available at 35 Hz and 75 Hz.
Vector Control
Modern inverters also offer vector control: using a mathematical model of the motor derived from an initial automatic measurement (autocalibration), the inverter separates the current that generates the magnetic field from the current that generates torque and controls them individually, as in a DC motor. This results in full torque even at near-zero speeds and rapid response to load changes. With an encoder on the shaft (closed-loop vector control), the induction motor can maintain torque even when stationary: this is how many CNC lathe spindles operate, as they must also position themselves for orientation and along the C-axis.
45.9 Ramp Rates, Braking, and Inverter Parameters
The ramps
The inverter does not suddenly jump to the required frequency: it changes it gradually along a ramp, with acceleration and deceleration times set in the parameters (usually referring to the change from 0 to the maximum frequency, or from 0 to 50 Hz). A ramp that is too short for the load’s inertia requires more torque than is available: during acceleration, the inverter goes into overcurrent; during deceleration, it goes into overvoltage. The minimum time is calculated using the rotational dynamics described in Chapter 9.
Braking
When the inverter reduces the frequency faster than the load would slow down on its own, the rotor spins faster than the field: the slip becomes negative, and the motor operates as a generator (paragraph 45.1). The load’s kinetic energy returns to the DC bus and causes its voltage to rise. The diode rectifier cannot feed this energy back into the grid, so there are three solutions:
- Extend the ramp, if the cycle allows it: the inverter automatically extends the deceleration to prevent overvoltage;
- braking resistance: a transistor (the chopper) connects a resistor to the bus when the voltage exceeds a threshold (for 400-V inverters, typically between 700 and 800 V) and converts the braking energy into heat;
- The regenerative power supply, which feeds energy back into the grid: it is used in the drives of CNC machines that involve frequent starts and stops, because it saves energy.
The spindle in Example 9.23 (moment of inertia 0.35 kg·m², 3000 rpm) must come to a stop in 1.5 s. Calculate the energy to be dissipated, the braking torque, the braking power, and the maximum resistance using a chopper that activates at 760 V.
The heating element is also selected based on its average power over time: if the spindle brakes once per minute, the 17.3 kJ corresponds, on average, to 17,272 / 60 = 288 W. The heating element generates heat: it should be installed in a well-ventilated area and away from cables and materials that are sensitive to heat.
Key Parameters
Every inverter has dozens or hundreds of parameters; the names and numbers vary from one manufacturer to another, but the fundamental ones are always these.
| Parameter | What it sets | Value for the engine on the license plate |
|---|---|---|
| Engine Specifications | Rated voltage, frequency, current, power, speed, and cos φ: these are used for control and thermal protection | 400 V, 50 Hz, 14.6 A, 7.5 kW, 1,455 rpm, 0.82 |
| Type of inspection | V/f, sensorless vector control, vector control with encoder | as is customary |
| Minimum and maximum frequency | Speed limits, even if the command calls for more | for example, 5 and 75 Hz |
| Ramp Times | Acceleration and Deceleration | for example, 2 s and 1.5 s |
| Source of Commands | Operation and speed via keypad, terminals (0–10 V, 4–20 mA), fieldbus | according to the system |
| Current Limit | Maximum current output of the inverter, typically 150% of the rated current for 60 seconds | about 22 A |
| Stop Mode | On an incline, in freewheel mode (the motor stops due to friction), with continuous braking | on a ramp |
| Switching frequency | Higher: quieter motor; lower: cooler inverter | 4–8 kHz |
| Autocalibration | Automatic Measurement of Motor Electrical Data | with the engine cold and disconnected from the load, if possible |
45.10 The Brushless Motor
A brushless motor is a permanent-magnet synchronous motor: the stator has three-phase windings like an asynchronous motor, and the rotor has permanent magnets (usually made of neodymium-iron-boron) glued or embedded on its surface. The rotating magnetic field created by the stator draws the magnets along, and the rotor rotates at exactly the same speed as the field, with no slip; this is why it is called a synchronous motor.
A brushless motor cannot be connected directly to the power grid: it requires a drive (a dedicated inverter) that knows the rotor’s position at all times, in order to send current to the correct windings at the right moment. The position is provided by an encoder or resolver mounted on the back of the motor (Chapter 47). The same sensor is used by the CNC to determine how far the axis has moved.
- High dynamic performance: The rotor is thin and lightweight (low inertia), and the motor delivers a peak torque 3–4 times the rated value for short periods. It accelerates and reverses direction in just a few milliseconds.
- Torque even when stationary: it holds the axis in position with its full rated torque (the stall torque, M0).
- High efficiency: No current flows through the rotor, so the rotor generates little heat; the heat is generated in the stator, near the housing, and is effectively dissipated.
- Note: Using the encoder, the controller regulates position, speed, and torque in a closed-loop system.
That is why brushless motors drive the axes of CNC machines (either directly on the ball screw or via a toothed belt; see Chapter 40), robots, tool changers, and, increasingly, spindles as well. Chapter 48 covers the complete system consisting of the motor, drive, and feedback rings, as well as how to select a servomotor.
An 8-pole brushless motor, with kt = 1.5 N·m/A, drives the lead screw (pitch 10 mm) of an axis. What is the frequency of the drive at 3000 rpm? What are the torque and power at 4 A? If the encoder has 220 counts per revolution, what is the minimum lead of the axis?
A Brief Note on Generators and Alternators
We have seen that every motor, when driven from the outside, generates voltage. A synchronous machine driven by a turbine or a diesel engine is an alternator: the rotor carries the poles (magnets or DC-excited windings), and the stator produces a three-phase voltage with a frequency of f = p · n / 60. Alternators are found in power plants, generator sets, and automobiles (in the latter, followed by a rectifier). A DC-driven machine is a dynamo; small dynamos, known as tachometer dynamos, were used to measure the speed of older motor units on axes. Brushless motors and asynchronous motors with inverters also act as generators when braking: the energy they return is recovered by regenerative power supplies.
At what speed must a 4-pole alternator run to produce 50 Hz? And a 2-pole alternator? And a 4-pole alternator to produce 60 Hz?
45.11 Stepper Motors and Linear Motors
The stepper motor (stepper) rotates in steps of a fixed angle; the angular step, every time its driver receives a pulse. The stator has two phases (A and B) that the driver powers sequentially; the magnetized, toothed rotor aligns with the magnetic field each time. The most common hybrid motor has a pitch of 1,8°, that is, 200 steps per revolution; there are also 0.9° motors (400 steps).
The advantage is simplicity: by counting the pulses, you know where the motor is located, without an encoder (this is referred to as open-loop operation). With microstepping, the driver adjusts the currents of the two phases to stop the rotor even at positions between two steps: 1/2, 1/8, 1/16 of a step, and beyond. The motion becomes smoother and quieter; however, the actual precision of the intermediate positions is lower than the theoretical resolution.
A 1.8°-pitch stepper motor directly drives a 5-mm-pitch lead screw. Calculate the resolution in full steps and with a 1/16 microstep, as well as the pulse frequency required to move the axis at 2 m/min.
The Risk of Missing Steps
The weakness of step-by-step control is that no one checks whether the rotor has actually executed the step. If the load requires more torque than is available (a collision, too abrupt an acceleration, increasing friction), the rotor fails to follow the field and misses steps: the controller believes the axis is in one position when it is actually elsewhere, and from that point on, all the dimensions are incorrect. Furthermore, the torque of a stepper motor drops significantly with speed, beyond a few hundred RPM. This is why they’re used in 3D printers, small milling machines, plotters, hobby machines, and dispensers; industrial machine tools use brushless motors or stepper motors with encoders (known as closed-loop systems) that detect missed steps.
A brief note on the linear motor
A linear motor is an “unrolled” brushless motor: the stator becomes a track of magnets attached to the base, and the rotor becomes a carriage with the windings (the primary) attached to the moving part. The force is generated directly in the direction of motion, without screws, belts, or clearances. Accelerations of up to a few g and very high speeds can be achieved, using an optical scale as a position sensor. It is more expensive, generates heat near the work area, and lacks the “braking” effect of a lead screw: if power is lost, a vertical axis will fall, so brakes and counterweights are required. It is found in high-speed machines, grinders, laser machines, and EDM machines.
45.12 Electric Spindles
In high-speed milling machines and machining centers, the motor does not drive the spindle via belts or gears: it is located inside the spindle. The electric spindle has its stator mounted in the housing and its rotor directly coupled to the tool-holding shaft, between the front and rear bearings. The motor can be asynchronous (driven by a vector inverter) or a brushless synchronous motor.
- Advantages: no belts or gears, so less vibration; high speeds (from 10,000 to over 40,000 rpm); rapid acceleration; compact size.
- Cooling: Motor losses occur inside the spindle, near the bearings and the tool. A channeled jacket carries away heat using water or oil cooled by a refrigeration unit; without it, the spindle would expand due to thermal expansion, and the Z dimensions would change during operation.
- Bearings: angular contact ball bearings, often with ceramic balls, lubricated with grease or air-oil. These are the components that wear out and break during impacts.
- Power curve: like the one in Figure 45.13, with a constant torque zone up to the base speed and a constant power zone above it. The catalog often provides two curves: S1 (continuous) and S6 at 40% (for short periods, higher).
Let’s use the curve shown in Figure 7.10: 11 kW in S1, base speed 1,500 rpm, maximum 6,000 rpm. A Ø63 steel end mill operates at Vc = 250 m/min, and the pass requires 8 kW from the motor; the same aluminum end mill at Vc = 1000 m/min. What power and torque are available? If the spindle has an efficiency of 0.9 at full load, how much water is needed to remove the heat generated, given a temperature increase of 5 °C?
The calculation for water uses the specific heat of water, 4186 J/(kg·°C): every kilogram of water that is heated by 1 °C absorbs 4186 J.
45.13 Selecting a Motor for a Load
Choosing a motor based solely on its rated power is the most common error. There are four questions you should ask yourself:
- what torque is required at rated load, and at what speed (for example, using the formulas in Chapter 26 or Chapter 40);
- what amount of inertia is needed to accelerate the engine, and how long it will take;
- how it operates over time (S1, S3, S6 duty cycles), how many starts per hour, and at what minimum and maximum speeds;
- In what environment: temperature, dust, water (IP rating), altitude.
The inertia transmitted to the crankshaft
Between the engine and the load, there is almost always a transmission with a gear ratio i = nengine / nload (Chapter 40). For the calculations, it is best to “view” everything from the crankshaft shaft. The resistance torque is divided by i (and for efficiency). The moment of inertia, on the other hand, is divided by i²: the kinetic energy of the load, ½ · Jc · ωc², must be equal to that of an equivalent flywheel on the crankshaft, ½ · Jrid · ωm², and since ωm = i · ωc is located Jrid = Jc / i². A sharp reduction makes even a heavy load almost invisible.
A roller with a moment of inertia of 0.8 kg·m² is driven by a motor via a belt with i = 2.5. What inertia does the motor “feel”? And what about the table with the screw from Example 40.22 (1.568 × 10−3 kg·m² as seen from the screw), if a belt is placed between the motor and the screw with i = 2?
A rotary table has a moment of inertia Jc = 30 kg·m² (including the workpiece), rotates at 60 rpm, and requires a torque of 150 N·m at steady state to overcome friction. It is driven by a gearbox with a gear ratio of i = 24 and an efficiency of η = 0.9, controlled by a 4-pole motor with an inverter, which can deliver 150% of the rated torque during startup. The table must reach its operating speed in 1 s. Rotor moments of inertia from the catalog (approximate): 1.1 kW 0.0030 kg·m², 1.5 kW 0.0040 kg·m², 2.2 kW 0.0055 kg·m². What motor is needed?
Two checks round out the selection process. The first is thermal: if the table performs many starts per hour, the acceleration current heats up the motor, and the catalog specifies the maximum number of starts, or the average torque during the cycle is calculated. The second concerns the ratio between the load inertia and the rotor inertia: in servomotors, if the reported inertia is much greater than that of the rotor, control becomes difficult (Chapter 48). Here, the ratio is 0.0579 / 0.0055 = 10.5, which is acceptable for an induction motor with an inverter.
45.14 Maintenance of Electric Motors
A properly selected and installed induction motor can last for decades. The most common causes of failure are always the same: bearings, winding insulation, and overheating. Please note that any work on electrical components must be performed by qualified personnel after the machine has been disconnected and secured.
Bearings
- Screened bearings (2Z, 2RS) are lubricated for life; those in large motors have a grease fitting and a label indicating the type of grease, the amount, and the relubrication interval: too much grease causes overheating, just as too little does;
- Alarms include noise (a rough hum or a whistling sound), vibrations that increase over time, and the temperature of the bearing housing; these are measured using vibration analysis instruments (Chapter 37);
- Belts that are too tight, misaligned joints, and unbalanced pulleys will wear out the bearings in just a few months: align them carefully (chapters 39 and 40);
- With inverters, currents can flow through the bearings along their raceways: insulated bearings, shaft grounding brushes, and properly connected shielded cables are used.
Insulation
- Moisture, conductive dust, cutting oil, and heat cause the windings' insulation to deteriorate; a motor that has been idle for a long time in a humid environment must be inspected before being put back into service;
- The test is performed by measuring the insulation resistance between the windings and the housing using a specialized instrument (megaohmmeter) that applies a DC test voltage: this is carried out by qualified technicians with the motor disconnected from the inverter, as the test voltage could damage it;
- It's a good idea to track values over time: the trend matters more than any single number.
Cooling
- The housing fins and the fan grille must be kept clean: a layer of chips and dust mixed with oil can cause the temperature to rise by several degrees;
- For every 10 °C above the temperature for which it is designed, the insulation's lifespan is reduced by about half (rule of thumb);
- In electric spindles, the level, flow rate, and temperature of the coolant, as well as the status of the cooling unit, are monitored, and the warm-up times at increasing speeds specified by the manufacturer are followed;
- If an engine gets hotter than usual, you should look for the cause: overload, a missing or unbalanced phase, low voltage, a broken fan, or too many starts.
45.15 The Formulas in This Chapter
| What | Formula |
|---|---|
| Force on a conductor | F = B · I · L |
| Pair on a spool | M = 2 · N · B · I · L · r |
| DC motor | V = E + R · I · E = K · ω · M = K · I |
| Synchronization Speed | n₀ = 60 · f / p |
| Scrolling | s = (n₀ − n) / n₀ · n = n₀ · (1 − s) · f₂ = s · f |
| Power Consumption and Efficiency | P₁ = √3 · V · I · cos φ · P = η · P₁ |
| Rated current | I = P / (√3 · V · cos φ · η) |
| Rated torque | Mn = 9549 · Pn / nn (kW, rpm) |
| Star-Triangle | Vphase = V / √3 · Is,Y = Is,Δ / 3 · Ms,Y = Ms,Δ / 3 |
| Reduced voltage | I ∝ V · M ∝ V² |
| Inverter Bus | Vbus ≈ √2 · V |
| V/f Control | V = Vn · f / fb (f ≤ fb) · Mdisp = Mn · fb / f (f > fb) · n ≈ 60 · f / p − Δn |
| Braking | Mf = J · ω / td · Ppeak = Mf · ω · R ≤ Vch² / Ppeak |
| Brushless Motor and Alternator | f = p · n / 60 · M = kt · I |
| Step-by-Step | z = (360° / α) · k · resolution = P / z · fimp = n · z / 60 |
| Quantities related to the motor | Mr = Mc / (i · η) · Jrid = Jc / i² |
| Acceleration time | ta = Jtot · ωm / (Mmot − Mr) |
45.16 Exercises
Try to solve them on your own, using a calculator, before looking at the solution.
Solution
F = 1,1 · 12 · 0,3 = 3,96 N.
Solution
E = 24 − 0.4 × 5 = 22 V, or 22 / 3000 V per revolution per minute. At 12 V: E = 12 − 2 = 10 V → n = 10 / (22 / 3000) = 1364 rpm.
Solution
6 poles: 60 × 60 / 3 = 1,200 rpm; 4 poles: 60 × 60 / 2 = 1,800 rpm.
Solution
n₀ = 3000 rpm; s = (3000 − 2900) / 3000 = 0.0333 = 3.33%; f₂ = 0.0333 · 50 = 1.67 Hz.
Solution
I = 4000 / (1.732 × 400 × 0.80 × 0.886) = 8.15 A; P₁ = 4 / 0.886 = 4.51 kW; Mn = 9,549 × 4 / 1,440 = 26.5 N·m.
Solution
Current: 60 / 3 = 20 A. Direct torque: 2.4 × 26.5 = 63.7 N·m; in a star configuration: 63.7 / 3 = 21.2 N·m.
Solution
The phase current in the delta connection: 21.5 / 1.732 = 12.4 A.
Solution
V = 400 · 20 / 50 = 160 V; n₀ = 60 · 20 / 2 = 600 rpm; nameplate slip: 1500 − 1440 = 60 rpm → n ≈ 540 rpm; constant torque range: 26.5 N·m (note: ensure adequate cooling at low speeds).
Solution
n₀ = 60 × 90 / 2 = 2700 rpm → n ≈ 2640 rpm; constant-power range, 4 kW: M = 9549 × 4 / 2640 = 14.5 N·m.
Solution
ω = 2 · 3.1416 · 1000 / 60 = 104.72 rad/s; E = ½ · 2 · 104.72² = 10,966 J; Mf = 2 · 104.72 / 4 = 52.4 N·m; Ppeak = 52.4 · 104.72 = 5,483 W.
Solution
p = 3: f = 3 × 4500 / 60 = 225 Hz; I = 8 / 0.9 = 8.9 A.
Solution
Pulses per revolution: (360 / 0.9) · 8 = 3200; resolution 4 / 3,200 = 0.00125 mm; n = 1,200 / 4 = 300 rpm; f = 300 · 3,200 / 60 = 16,000 Hz.
Solution
Jrid = 1.2 / 10² = 0.012 kg·m²; Jtot = 0.014 kg·m²; ω = 157.08 rad/s; t = 0.014 · 157.08 / 20 = 0.11 s.
Solution
At 1,200 rpm, the engine is in the constant torque range (70.0 N·m): P = 70.0 × 1,200 / 9,549 = 8.8 kW. This is not enough: you must either reduce the pass rate or increase the rpm if the tool allows it.