Linear Measurements
A drawing is full of dimensions: outer and inner diameters, lengths, depths, shoulders, slot widths, center distances, and thicknesses. For each one, there is the right tool and the right way to use it. In this chapter, we’ll go through the tools for linear measurements one by one—from the ruler to the micrometer, from the dial indicator to the gauge blocks—and learn how to read them with confidence. Finally, we’ll look at the methods for measuring the most common dimensions and how to choose the right tool based on the tolerance.
32.1 Instrument Families
Linear measuring instruments are divided into three categories, depending on the type of result they provide:
- Direct-reading instruments: These have a scale and display dimensions in millimeters. They include the ruler, the vernier caliper, the micrometer, and the height gauge. They are used for individual workpieces, for setting up tools, and when it is necessary to know how far a workpiece is from the specified dimension;
- comparison instruments: they do not measure the full dimension, but rather the difference between the workpiece and a known reference standard (blocks, rings, or a reference specimen). These include the dial indicator, the lever-type comparator, and the bore gauge. Over a small range, they are much more accurate than direct-reading instruments;
- Fixed gauges: They do not provide a numerical value, only “good” or “reject.” These include pass/fail gauges, feeler gauges, and spoke gauges. They are extremely fast and are used in mass production.
For each instrument, there are two different numbers that should not be confused. Resolution is the smallest increment displayed by the instrument (0.02 mm for a 50-division vernier caliper, 0.001 mm for a digital micrometer). Uncertainty refers to how much the measurement may actually be off, taking into account the instrument, the operator, the temperature, and the workpieces. Uncertainty is always greater than resolution: a digital caliper displays hundredths, but can easily be off by two or three hundredths. Measurement errors, uncertainty, the rule of tenths, Abbe’s principle, and the effect of temperature are explained in Chapter 31; here we refer to them as needed and focus on the instruments and methods.
32.2 Rulers, Meters, and Tape Measures
A metal ruler is a stainless steel blade graduated in millimeters, often with half-millimeter markings on the first few centimeters. It is used for rough measurements: cutting bars, checking blanks, and marking out. Its resolution is one millimeter (half a millimeter with a good eye), and its uncertainty, under normal use, ranges from 0.2 to 0.5 mm. The tape measure (retractable measuring tape) and the rigid ruler are used for lengths of a few meters, with an uncertainty of about one millimeter or more.
There are three common errors involving the line:
- Zero: The edge of the ruler wears down, and the zero mark is no longer reliable. It’s best to rest the workpiece against a stop square, or start from the 10-mm mark and subtract 10 from the reading;
- Parallax: If the eye views the mark at an angle, it reads a nearby mark. The eye must be positioned directly over the mark, and the ruler must be held at an angle, with the marks in contact with the workpiece;
- The hook on the tape measure: The hook at the tip is intentionally designed to move by an amount equal to its thickness, so that it measures the same whether it is hooked on the outside or pressed against a wall. If it is bent or loose, all measurements will be subject to the same error.
32.3 The Sliding Caliper
The vernier caliper (or simply “caliper”) is the most commonly used tool in the workshop: with a single tool, it measures external diameters, internal diameters, and depth, with a resolution ranging from 0.1 to 0.02 mm. It consists of a rod graduated in millimeters, which holds the fixed jaw, and a sliding block that moves along the rod and holds the movable jaw and the vernier scale.
- outdoor calipers (below): they clamp onto the workpiece and measure diameters, lengths, and thicknesses;
- internal calipers (top, knife-type): they are inserted into the hole and open against the walls; they measure holes, grooves, and distances between two walls;
- depth rod: a blade that extends from the end of the rod when the slide opens; measures the depth of holes, slots, and steps;
- locking screw: secures the slide so you can read the measurement at your leisure or use the caliper as a reference;
- Thumb wheel: moves the slide gently. The caliper does not have a ratchet like a micrometer; the measuring force depends on the hand.
A standard workshop caliper measures up to 150 mm; there are calipers measuring 200, 300, 500 mm, and more, but the longer the rod, the more easily it bends and the more clearance the sliding block has. The caliper does not follow Abbe’s principle (Chapter 31): the scale is on the rod, and the workpiece is lower down, between the jaws. If you tighten it too much, the sliding block tilts slightly on the rod and the tips of the jaws spread apart; for this reason, you should measure as close to the rod as possible, using the inner part of the jaws, and apply a light, consistent force.
32.4 The vernier scale: how to read it
The markings on the rod are spaced one millimeter apart: on their own, they allow you to read only whole millimeters. The vernier scale is a small scale on the slide that divides the millimeter into finer parts. The idea is simple: the vernier markings are slightly closer together than those on the rod.
The Decimal Vernier Scale
On the decimal vernier scale, 10 vernier divisions span 9 mm: each vernier division measures 0.9 mm, which is 0.1 mm less than a division on the main scale. With the jaws closed, the zero mark on the vernier aligns with the zero mark on the scale, and the tenth mark on the vernier aligns with the 9 mm mark. The intermediate marks do not coincide: the first vernier mark is 0.1 mm before the 1-mm mark, the second is 0.2 mm before the 2-mm mark, and so on. If you now open the slide by 0.3 mm, the third mark on the vernier coincides with the 3-mm mark on the scale. The number of the mark that coincides indicates how many tenths are beyond the whole millimeter.
The elongated 20-division vernier scale (39 mm) has markings spaced nearly 2 mm apart: it is easier to read than a shorter 19-mm scale that would provide the same resolution.
The Reading Method
- Read the whole millimeters on the scale that are before the zero mark on the vernier scale (the zero mark on the vernier scale serves as a reference point);
- Find the vernier scale mark that is exactly aligned with any mark on the rod: it doesn't matter which mark on the rod it is; only the number of the vernier scale mark matters;
- Multiply the number on that mark by the resolution and add it to the whole millimeters.
The numbers printed on the vernier scale help with counting: on the decimal scale, there are 0, 5, and 10; on the twentieth and fiftieth scales, the numbers from 0 to 10 indicate tenths of a millimeter. The marks between two numbers represent 0.05 mm on the 1/20 scale (a single mark in between) and 0.02 mm on the 1/50 scale (four marks in between).
32.5 How to Use a Caliper Properly
The Four Measures
- External: Place the workpiece as close as possible to the spindle, at the base of the jaws; the jaws must be perpendicular to the axis of the workpiece. Swing the caliper slightly along one diameter: the correct measurement is the smaller one;
- Internal: The knife-edge jaws enter the hole and spread against the walls; look for the largest measurement in the diameter plane and the smallest in the axial direction (the gauge must be perpendicular to the hole’s axis). For small holes, the thickness of the blades and their shape result in a measurement slightly smaller than the actual size;
- depth: the head of the gauge rests flat against the reference surface, and the depth rod extends all the way to the bottom. Hold the gauge perpendicular to the surface, applying pressure to the head and not to the rod;
- Step height (height of a step): same technique as for depth, with the head on the upper step and the rod extending down to the lower one. Some calipers have two stop faces specifically designed for this purpose on the tail of the slide.
On some calipers, especially the larger ones, holes are measured using the outer tip of the lower jaws, which has a rounded shape. The thickness of the two closed jaws is engraved on these jaws, for example, “10 mm.” The reading on the vernier scale is 27.64 mm: how wide is the hole?
Dial and Digital Calipers
In a dial-type caliper, the vernier scale is replaced by a small comparator on the slide: a pinion meshes with a rack on the slide and moves an index. Millimeters are read on the rod, and hundredths (or two-hundredths) on the dial; typically, one full rotation of the pointer equals 1 or 2 mm. The digital caliper has a capacitive or inductive measuring bar and displays the measurement on a screen, usually with a resolution of 0.01 mm. It offers two conveniences: it can be zeroed in any position (for differential measurements) and passes from millimeters to inches with the push of a button. Be careful, though: a resolution of 0.01 mm does not mean precision to the hundredth. Caliper standards allow for errors in the range of 0.02 or 0.03 mm for digital calipers up to 150 mm.
Common Errors
- Unchecked zero: Before taking a measurement, close the clean jaws and check that the zero mark on the vernier scale aligns with the zero mark on the measuring rod (or that the digital display reads 0.00). Jaws with worn tips give different readings at the tip and at the base;
- Too much force: the clamp tilts and the jaws open; on soft or thin workpieces, the workpiece becomes deformed;
- crooked caliper: a tilted caliper measures a chord longer than the diameter on the outer side and a shorter chord on the inner side;
- Parallax on the vernier scale: always look straight down;
- measurement at the tips of the prisms: the farther the workpiece is from the rod, the greater the Abbe error;
- a hot or dirty workpiece, and burrs on the edge.
Special Gauges
For dimensions that standard calipers cannot measure, gauges with specially shaped jaws are manufactured:
- For internal grooves and slots: long prongs with tips bent outward like hooks, which enter the hole and open up inside the groove. The measurement often needs to be adjusted for the thickness of the tips, which is engraved on the prong;
- For center-to-center distances: pins with tapered tips that align themselves in the two holes; the distance between the axes can be read directly, provided the holes are large enough for the tips;
- For pipe thicknesses: one probe is shaped like a small cylinder or a round rod that enters the pipe and touches the inner wall along a line, while the other probe touches the outer wall;
- long-nose pliers, pliers for narrow external grooves, pliers for O-ring grooves, and blade-nose pliers for narrow slots.
32.6 Truschino and Height Gauge
The reference surface is a very flat, precision-ground slab of granite or cast iron: it serves as the reference surface on which the workpiece and the measuring instrument rest for marking and measuring heights. All heights are measured from this surface, which becomes the common “zero” point.
The truschino is a heavy base with a column, along which a clamp slides, carrying a hardened steel point for marking. The point is adjusted to the desired height (using a vertical ruler or shims) and then dragged across the workpiece, which has been coated with marking paint beforehand; this leaves a thin, clearly visible line. The modern truschino often also features a dial indicator in place of the point, to check the parallelism of the surfaces.
The height gauge is an upright sliding caliper: the rod is vertical, secured to a ground base, and the slide is fitted with a carbide tip used for both measuring and marking. Digital bench-top models offer resolutions as high as 0.01 mm (or even 0.001 mm for metrology lab models) and can store data points, calculate the center of a hole, and determine the distance between two points.
To measure a height, set the tip to zero on the surface, then gently move it to the face of the workpiece. To determine the position of a horizontal hole, touch the lowest point of the hole (with the tip pointing up) and the highest point (with the tip pointing down); the average gives the height of the center, and the difference gives the diameter.
A block is resting on a reference plane and has a horizontal hole. Using a depth gauge, zeroed to the plane, the reading is 34.26 mm on the lower generatrix of the hole and 54.30 mm on the upper generatrix. Where is the center, and what is the diameter of the hole?
The thickness of the probe doesn't matter, as long as you zero it out by rotating the probe in the same direction as the measurement: many digital calipers have a dedicated button that accounts for the probe's thickness when you rotate it.
32.7 The Micrometer
The micrometer (also known in the workshop as a “Palmer,” after its inventor) measures using a precision screw. It is much more accurate than a vernier caliper for two reasons: it follows Abbe’s principle, because the screw is aligned with the dimension being measured, and the screw multiplies the movement, so that a small shift of the rod results in a large rotation of the drum, which is easy to read.
- arch: rigid and heavy, supports the anvil and the screw; often has insulating plates;
- anvil and rod: the two measuring surfaces, made of hard metal, flat and parallel;
- graduated cylinder (sight): attached to the bow, it bears the sight line with millimeter marks above and half-millimeter marks below;
- drum: rotates along with the screw and has 50 divisions on its edge;
- ratchet (or clutch): when the rod touches the workpiece, it slips with a slight click and ensures a consistent measuring force, usually between 5 and 10 N;
- locking ring: holds the rod in place so you can read it without touching the drum.
The Principle of the Micrometer Screw
The metric micrometer screw has a pitch of 0.5 mm: with each complete rotation of the drum, the rod advances by half a millimeter. The drum is divided into 50 divisions: turning it one division moves the rod by 0.5 / 50 = 0.01 mm. Millimeters and half-millimeters are marked on the cylinder, while hundredths are marked on the drum.
Case c) is the classic trap: the edge of the drum is almost at the 6-mm mark, and the drum’s zero is just above the reference line. A quick glance might read 6.99 or 6.49. The drum reads 49: it’s one cent short of the next half-turn, so the 6 mm mark cannot be visible yet.
The millesimal vernier scale
Some mechanical micrometers have a vernier scale on the cylinder, above the reference line, consisting of 10 lines that span the space of 9 divisions on the drum. It works like the vernier scale on a caliper: the vernier line that aligns with a line on the drum indicates the thousandths. Today, digital micrometers with a resolution of 0.001 mm are often used instead; but be aware that even a good thousandths micrometer has an uncertainty of 2 or 3 µm.
The Outdoor Micrometer in Use
The screw travel is 25 mm; for this reason, external micrometers are manufactured in 25-mm ranges: 0–25, 25–50, 50–75, 75–100 mm, and so on, up to over 1,000 mm. A 25–50 micrometer cannot measure 20 mm: the measuring rod cannot move closer to the anvil than 25 mm. There are also micrometers with interchangeable anvils, which cover a wider range of measurements.
Zeroing
- The 0-25 micrometer is zeroed by closing the rod onto the clean anvil using the ratchet;
- For measurements of 25–50 and above, use the calibration rod (also called a reference rod) provided by the manufacturer with the instrument: a small cylinder of known length—25, 50, or 75 mm—with flat ends and an insulating sleeve. Close the micrometer around the gauge bar and verify that the reading is exactly 25.000 (or 50.000, ...);
- If the reading is incorrect, turn the graduated cylinder with the supplied key until the reference line aligns with the zero mark on the drum. Check it frequently, and always after a bump.
Ratchet and Constant Force
The micrometer screw offers a huge mechanical advantage: by squeezing the drum with your fingers, you can generate forces capable of bending the bow or compressing the workpiece by a few micrometers. For this reason, the final adjustment is made always with the ratchet: Turn it slowly until it clicks two or three times. This ensures that the measuring force is the same for every measurement and for every operator. Hold the micrometer by the insulating plate—never by the bare jaw—and do not leave it in the sun or on top of a hot machine.
- When measuring diameters, gently rock the micrometer back and forth and from side to side: the correct measurement is the minimum along the axis and the maximum across the diameter;
- Before putting it away, leave the rod slightly separated from the anvil: if the surfaces are in contact, a change in temperature could cause them to stick together;
- The flatness and parallelism of the measuring surfaces are checked in the metrology lab using flat optical glass plates: by observing the colored fringes that form between the glass and the surface, errors of a few tenths of a micrometer can be detected.
32.8 Indoor Micrometers and Special-Purpose Micrometers
The Three-Point Internal Micrometer
The three-point internal micrometer (also known in the workshop as a “three-contact bore gauge” or by a brand name) has a head with three probes spaced 120° apart. When the drum is rotated, an internal cone pushes all three probes out at once until they touch the wall of the hole. The three contact points automatically center the instrument: there is no need to locate the diameter as with a caliper, and the measurement is highly repeatable. Each head covers a small range (for example, from 20 to 25 mm, or from 50 to 63 mm) and is zeroed using a reference ring of known diameter. The resolution is 0.005 or 0.001 mm.
The two-point, rod-type internal micrometer
For large holes, a two-point micrometer, or rod micrometer, is used: a micrometer head with two spherical contacts at each end, which can be extended with screw-on extensions of known lengths (13, 25, 50, 100 mm, and longer). The measurement is the sum of the reading from the head and the extensions. The instrument contacts the surface at only two points: it should be moved back and forth to find the maximum value in the transverse plane and the minimum value in the axial plane, just like a bore gauge (paragraph 32.10).
A micrometer head with a measuring range of 50 to 75 mm reads 61.48 mm; the 25-mm and 50-mm extensions are attached. What is the diameter of the hole?
Each joint adds a little uncertainty: use as few extension pieces as possible and check the assembly against a nearby reference, if available.
Other micrometers
- Depth micrometer: a wide, flat base that rests on the reference surface and a rod that extends into the hole or groove. The rods are interchangeable in 25-mm increments. Note: The scale is reversed; the numbers increase as you screw the rod in, because the further the rod extends, the greater the depth.
- plate micrometer: The measuring surfaces consist of two thin discs. It is inserted between the teeth of a gear and measures the Wildhaber dimension—that is, the distance between the flanks of a group of teeth—which is used to check the thickness of the teeth (Chapter 37). It is also used for soft workpieces such as paper, rubber, and plastic;
- blade micrometer: the anvil and the rod are two thin, non-rotating blades that fit into narrow, hollow external grooves of small diameter;
- thread micrometer: with interchangeable conical and V-shaped tips, measures the average diameter of a thread (Chapter 35);
- spherical-tip micrometer for tubes: the anvil is a sphere or a cylindrical rod that enters the tube and touches the inner wall; it measures the wall thickness;
- jaw micrometers for measuring grooves and thicknesses in hard-to-reach areas, and V-anvil micrometers for workpieces with an odd number of lobes or cutting edges (reamers, end mills).
32.9 The Comparator
The comparator (or dial comparator) measures displacements: a stem with a probe slides inside a sleeve, and its movement is magnified by a gear train until it causes a pointer to rotate on a dial. It is not used on its own: it is mounted on a stand and zeroed against a reference (blocks, a test workpiece, or the machine surface). It is used for comparative measurements, to check eccentricity, flatness, and parallelism, to center a workpiece on a lathe, or to align a vise on a milling machine.
- centesimal comparator: dial with 100 divisions of 0.01 mm; one full rotation of the index = 1 mm; the small dial counts the millimeters. The most common travel is 10 mm;
- thousandth-of-a-millimeter comparator: graduations of 0.001 mm; one revolution is usually 0.2 mm (200 graduations), and the travel is 1 or 5 mm;
- Rotating bezel: The dial rotates with the bezel to align the zero mark with the index in any position; the tolerance hands—two indices marked on the bezel—indicate the limits and allow you to immediately see if the workpiece is within specification.
When the stem retracts (the workpiece pushes), the pointer moves clockwise and the numbers increase: this is the “plus” direction. For a comparative measurement, zero the dial gauge on the sample, place the workpiece under the probe, and read how much the pointer has moved and in which direction. The dial indicator should be mounted with the stem perpendicular to the surface and slightly preloaded (half a turn or one turn), so that readings can be taken in both the “plus” and “minus” directions.
Magnetic Mounts and Columns
The comparator is mounted on a magnetic stand (a base with a switch-type magnet and articulated, rigid, or centrally articulated arms) or on a bench column with a ground-flat support surface or a reference plate. There is only one rule: the arm should be as short and rigid as possible, and every joint must be tightly secured. A long, flexible arm moves under the force of the stem spring and introduces errors of a few hundredths.
The lever-type comparator
The lever-type comparator (or probe, or “tester”) has a small lever-type stylus that swings around a pivot instead of a sliding stem. It is small and can reach hard-to-reach places: the inside of a hole, a slot, or the face of a workpiece on the spindle. The travel is short (0.5 or 0.8 mm), with a resolution of 0.01 or 0.002 mm. The stylus can be oriented, and the reading direction is reversed using a small lever.
The stylus must be held parallel to the surface being measured—that is, perpendicular to the direction of displacement. If it is tilted at an angle α, the dial indicator reads a value greater than the true value: this is the cosine error, discussed in Chapter 31.
When checking the eccentricity of a hole, a dial indicator with the stylus angled at 30° relative to the surface reads 0.040 mm. What is the actual offset? And at 15°?
32.10 The Dial Bore Gauge
The bore gauge is the most commonly used instrument for measuring precision holes in manufacturing. It consists of a rod with a two-contact head at the end: one fixed contact (interchangeable depending on the diameter) and one movable contact, which, via a right-angle linkage, moves the stylus of a dial indicator mounted at the top of the rod. A spring-loaded centering bridge next to the contacts keeps the head centered on the hole’s diameter.
It is a tool for comparison: first, you set it to zero using a reference of known diameter, then you read how much the hole differs. The reference can be:
- a nominal-size reference ring, the best reference;
- an outdoor micrometer locked at the desired measurement, with clean measuring faces: more practical, but less accurate;
- a stack of blocks between two clamps, in a special block holder.
The Search for the Minimum
When inserted into the hole, the bore gauge touches two opposite points. If the rod is perpendicular to the axis, the contacts measure the diameter; if it is tilted, they measure a longer, oblique chord. The rod is then swung back and forth in the plane containing the hole’s axis, while observing the pointer: the pointer moves forward and then back, and the point at which it reverses direction is the correct reading. In the transverse plane, however, the centering bridge already holds the head on the diameter. The reading is taken in the same way during zeroing in the ring.
Pay attention to the direction. When the movable contact retracts (the hole is smaller than the ring), the dial indicator’s stem is pushed inward and the pointer turns clockwise. Therefore, with most bore gauges, a reading “plus” means the hole is smaller than the reference, while a reading “minus” means the hole is larger. To avoid mistakes, many operators mark the dial with “−” and “+” to indicate the hole size.
A bore gauge with a thousandth-of-a-millimeter dial is zeroed on a 40.000 mm ring. In the hole, at the reversal point, the pointer stops 7 divisions before zero, that is, in the counterclockwise direction. Is the hole acceptable? (Ø40 H7 = 40.000 to 40.025 mm, Chapter 14)
By measuring at three depths and in two directions at 90°, the taper and ovality of the hole are also checked (paragraph 32.13).
32.11 Spacer blocks
Reference blocks (plane-parallel blocks, or Johansson blocks, named after their Swedish inventor) are the workshop’s lengths standards. They are parallelepipeds made of hardened and tempered steel, cemented carbide, or ceramic, with two measuring faces lapped so flat and parallel that the distance between them is guaranteed to be within a few tenths of a micrometer. They are used to zero out dial indicators and bore gauges, calibrate micrometers and calipers, adjust the vernier caliper, and check fixed gauges.
The Classes
The ISO 3650 standard specifies four classes, which differ in terms of the permissible deviations in lengths and face parallelism:
- Class K: calibration blocks, used with their certificate to calibrate other blocks;
- Class 0: metrology room, inspection of gauges and precision instruments;
- Class 1: in-department inspection, zeroing of thousandths-of-a-unit instruments;
- Class 2: Workshop, setup, and adjustment of machines and precision instruments.
For a 25-mm block, the permissible deviations range, as a general guideline, from just over one-tenth of a micrometer (Class 0) to about six-tenths of a micrometer (Class 2). The exact values can be found in the standard or in the manufacturer’s certificate.
The Series
The blocks are sold in sets designed to allow you to build any dimension with just a few workpieces. The two most common sets, which we use in the examples, are these (the contents may vary slightly by manufacturer; refer to the list included with your set):
| Group | 87-workpiece set | 112-workpiece set |
|---|---|---|
| vintages | from 1.001 to 1.009 in increments of 0.001 (9 workpieces) | 1.0005 (1 workpiece) and from 1.001 to 1.009 in increments of 0.001 (9 workpieces) |
| cents | from 1.01 to 1.49 in increments of 0.01 (49 workpieces) | from 1.01 to 1.49 in increments of 0.01 (49 workpieces) |
| half a millimeter | from 0.5 to 9.5 in increments of 0.5 (19 workpieces) | from 0.5 to 24.5 in increments of 0.5 (49 workpieces) |
| large | from 10 to 100 in increments of 10 (10 workpieces) | 25, 50, 75, 100 (4 workpieces) |
| total | 87 | 112 |
Dimensions in mm. Typical sets, provided by CNC Simulator Italia as examples; sets of 32, 47, and 103 workpieces are also available, as well as sets with protective blocks.
Entering a dimension: the "last digit" method
A dimension is made up of as few blocks as possible, because each addition introduces a very small error, and each block adds its own deviation. The method is always the same: you eliminate one digit at a time, starting with the rightmost one.
- Select the block that removes the thousandths digit (from the 1.00x series) and subtract it from the dimension;
- With the remaining amounts, choose the block that eliminates the cents and tenths (in the range from 1.01 to 1.49);
- then the one that removes the half-millimeters and the units;
- Finally, the large blocks for everything else.
112-workpiece set:
87-piece set: the first two workpieces are the same (1.005 and 1.37); for 39 mm, you need 30 and 9 → 1.005 + 1.37 + 9 + 30 = 41.375 ✓
41.375 = 1.005 + 1.37 + 14 + 25 (series 112) = 1.005 + 1.37 + 9 + 30 (series 87): four bookletsThe trick for the second step is a common one: when the cents exceed 0.49, you take the block with the same number of cents and the tenths that leaves a multiple of 0.5 mm (in this case, 1.31, because 62.81 − 1.31 = 61.5).
Adhesion, Cleanliness, Temperature
Two clean workpieces, slid one over the other with light pressure, remain stuck together as if they were a single workpiece: this is adhesion (known as “wringing” in English), caused by the extremely thin film of oil and the forces between such flat surfaces. The thickness of the film is negligible, amounting to a few hundredths of a micrometer. Rules for use:
- Clean the faces with refined gasoline or a special cleaner and a leather pad or lint-free cloth; never touch the measuring faces with your fingers;
- First, attach the thin blocks to the thick ones in a crisscross pattern, and then rotate them: a thin block bends easily;
- After use, separate them by sliding them apart (never pulling them), clean them, and protect them with a thin layer of oil or petroleum jelly: if left attached for days, they will “stick together” and become scratched;
- Handle them as little as possible, and only with collets or gloves: the heat from your hands causes the block to stretch.
A 100-mm steel block, held in the hand while the measurement is being taken, heats up by 2 °C. How much does it expand? (The coefficient of thermal expansion (α) of the steel blocks is approximately 11.5 × 10−6 1/°C, Chapter 31)
32.12 Fixed gauges: pass/fail, thickness gauges, radius gauges
Differential pass/fail gauges were introduced in Chapter 14: the PASS side corresponds to the maximum material dimension and must fit, while the FAIL side corresponds to the minimum material dimension and must not fit. For holes, plug gauges are used; for shafts, fork gauges and ring gauges are used. The “FAIL” side can be identified because it is shorter and marked in red.
Taylor's Principle
A real workpiece is not a perfect cylinder: it can be oval, conical, or crooked. Taylor’s principle specifies how the two sides of the gauge must be made so that no defective workpieces are accepted:
- The PASSA side must be complete: a cylinder as long as the fit (for a plug) or a complete ring (for a shaft). This ensures the entire shape fits together properly: if the hole is too tight even at a single point, or if it is crooked, the plug will not fit;
- The DO NOT PASS side must check one point at a time: a short probe, or better yet, a two-contact bar, or a two-pronged fork. That way, if the hole is too wide in even just one direction, the gauge will detect it.
That's why shaft forks are not ideal for the non-passing side, while the ring is better than the fork for the passing side; many workshops use the fork for both sides for convenience, knowing that it doesn't detect ovality.
From Chapter 14, for the 18–30 mm group: H7 = 0/+21 µm, g6 = −7/−20 µm.
True gauges have a small manufacturing tolerance and a margin for wear, always shifted toward the inner limit of the workpiece’s tolerance, in accordance with gauge standards: a worn gauge must reject some good workpieces, but never accept a defective one. They are periodically checked using micrometers, gauge blocks, and gauge rings.
There are also plug and ring gauges for threads, which check a thread using the same principle: the “go” side has the complete profile and must screw in along its entire length, while the “no-go” side has only a few threads and must not screw in more than a couple of turns. These are covered in Chapter 35.
Thickness Gauges and Spoke Gauges for Radii
A feeler gauge is a set of steel strips of known thickness, each marked with its thickness (from 0.02 or 0.03 up to 1 mm). It measures clearances and gaps: the clearance between two workpieces is the thickness of the thickest strip that fits with a slight drag. Overlapping strips can be added together, but no more than two or three. It is used to adjust the clearances in valves, guides, and gears, and to check the fit of a workpiece in a vise.
Radius gauges (radius gauges) are small metal plates with a convex radius on one side and a concave radius on the other, available in series ranging from 1 to 7 mm, 7.5 to 15 mm, and so on. Place the gauge against the fillet of the workpiece and hold it up to the light: the radius is correct when the light passing through is uniform and very narrow. Thread gauges (thread counters) and chamfer gauges work using the same method.
32.13 Common Methods for Measuring Dimensions
Outer Diameters
A diameter is never measured at a single point. It is measured at at least three points along the axis (near the ends and in the middle) and, at each point, in two directions at 90°. This allows for the detection of two different defects:
- Ovality: the difference between the two measurements at the same cross-section. It can result from a workpiece that was clamped improperly, a machine with a worn spindle, or a thin workpiece deformed by the jaws;
- Taper: the difference between the average diameters of different cross-sections. It results from the deflection of the workpiece during cutting (a long shaft without a tailstock), tool wear, or misalignment of the tailstock.
A turned shaft with a diameter of 30 is measured with a micrometer: section A (near the spindle) 30.012 and 29.998 mm; section B: 30.008 and 29.996 mm; section C (at the tip): 30.004 and 29.992 mm. Calculate the ovality and taper.
A two-point measurement detects ovality but not three- or five-lobe defects: to determine true circularity, you need a V-block micrometer or the rotational measurement described in Chapter 34.
Inner diameters
For holes, the choice depends on the tolerance: a gauge for through holes, a three-point micrometer or a bore gauge for mating holes, and a standard pass/fail plug gauge. Holes are also measured at multiple depths (at the entrance, in the middle, and at the bottom) and in two directions: a reamed hole may be bell-shaped or barrel-shaped. In blind holes, measurements are also taken near the bottom, where the tool deflects the most.
Depth of holes and slots
Use a depth gauge (depth rod) for rough dimensions, or a depth micrometer or dial indicator on a flat base for precise dimensions. The base must rest on a clean, flat surface and completely cover the hole or slot. In the case of a drilled blind hole, keep in mind that the bottom is tapered: the “effective” depth specified in the drawing is measured up to the start of the taper, not to the very tip.
Shoulder Picks
The length between two shoulders on a shaft is measured with a caliper (using the outside jaws if there is enough space; otherwise, using the depth rod resting against the higher shoulder). For precise dimensions, use a height gauge on the reference surface, or a dial indicator zeroed on blocks. In CNC lathe production, the dimensions of the shoulders are often checked by measuring from the reference face of the workpiece—the same face from which the dimensioning begins (Chapter 13).
Width of grooves and tabs
The width of a keyway is measured using the inside jaws of a caliper, with blocks (the largest block that fits), or with a flat pass/fail plug. The tongue, which is a “shaft,” is measured with a micrometer. The depth of the groove on the shaft is usually checked using the “shaft minus groove” dimension, measured with a micrometer from the bottom of the groove to the opposite side of the diameter.
Center-to-center distance between two holes
The center-to-center distance cannot be measured directly because the axes do not touch. You measure the distance between the edges of the holes and adjust it based on the diameters:
- With the inner jaws open across the two holes, measure the distance between the outer edges, Le: the center-to-center distance is Le minus the sum of the two radiuses;
- Using the outdoor pliers, insert the tips into the holes and clamp them onto the material bridge to measure the distance between the inner edges Li: the center-to-center distance is Li plus the sum of the two radii.
Two holes in a plate measure 10.02 and 10.00 mm. Using the internal calipers, the distance between the outer edges is measured as Le = 62.42 mm. What is the center-to-center distance?
Two holes measuring 12.00 and 8.00 mm; the distance between the inner edges is Li = 35.15 mm. Center-to-center distance?
For a more precise measurement, insert two ground pins into the holes so that they fit without any clearance, and measure above the pins with a micrometer: I = measurement above the pins − (d1 + d2)/2, where d is the diameter of the pins.
Distance of a hole from an edge and wall thickness
The distance from the axis of a hole to an edge is calculated in the same way: measure the distance a between the edge of the workpiece and the nearest edge of the hole (using a depth gauge or internal calipers), and add the radius. It is also advisable to measure to the far edge of the hole and subtract the radius; the average of the two measurements is more reliable. The wall thickness of a tube is measured with a ball-nose micrometer or a tube gauge; the thickness of the bottom of a blind hole is calculated as the difference between the length of the workpiece and the depth of the hole.
A hole measures 16.00 mm. The distance from the edge of the plate to the near edge of the hole is 8.64 mm, and to the far edge is 24.66 mm. Where is the center of the hole?
32.14 Choose the tool based on the tolerance
The tool is selected based on the dimension tolerance. The one-tenth rule (Chapter 31) states that the instrument’s uncertainty, under operating conditions, must be no more than about one-tenth of the tolerance. An instrument that is too coarse will accept defective workpieces and reject good ones; one that is too fine is costly and unnecessarily slows down the process. The table provides approximate values for instruments in good condition, used by skilled operators on clean workpieces at a controlled temperature.
| Tool | Resolution (mm) | Typical uncertainty (mm) | Recommended tighter tolerance (mm) |
|---|---|---|---|
| Metal ruler, tape measure | 0,5 a 1 | ±0,3 a ±1 | ±1.5 or more |
| 1/20 Vernier Caliper | 0,05 | ±0,05 | ±0,25 (T = 0,5) |
| 1/50 Vernier Caliper, Dial-Type, Digital | 0,02 o 0,01 | ±0,02 a ±0,03 | ±0,1 a ±0,15 |
| Digital Height Gauge | 0,01 | ±0,02 a ±0,03 | ±0,1 a ±0,15 |
| Centesimal Micrometer | 0,01 | ±0,004 a ±0,005 | ±0,02 a ±0,025 |
| Millesimal or Digital Micrometer | 0,001 | ±0,002 a ±0,003 | ±0,01 a ±0,015 |
| Three-point internal micrometer | 0,005 o 0,001 | ±0,003 a ±0,005 | ±0,015 a ±0,025 |
| Alesameter with a thousandth-of-an-inch dial indicator | 0,001 o 0,002 | ±0.002 to ±0.004 (with a good ring) | ±0,01 a ±0,02 |
| Centesimal column comparator, for comparison | 0,01 | ±0.005 to ±0.01 (for small differences) | ±0,03 a ±0,05 |
| Column-mounted thousandth-of-an-inch comparator, with blocks | 0,001 | ±0,001 a ±0,002 | ±0,005 a ±0,01 |
| Pass/Fail Gauges | none (pass/fail) | It depends on the caliber | Grade IT6 and above |
Approximate values prepared by CNC Simulator Italia; the actual uncertainty is derived from the calibration certificate and the measurement conditions (Chapter 31). The right-hand column applies the rule of tenths: the total tolerance T is approximately ten times the uncertainty. In the workshop, for non-critical dimensions, a tighter ratio (one-fifth) is sometimes accepted, but this decision must be made with due care.
A drawing specifies the following: a length of 120 ± 0.1 mm, a diameter of Ø25 h6 (tolerance 13 µm, Chapter 14), and a hole of Ø40 H7, to be inspected on 100 workpieces.
32.15 The Formulas in This Chapter
| What Are You Looking For? | Formula | Units |
|---|---|---|
| Vernier scale resolution | r = 1/n · Lnonio = m · (n − 1) · q = m − r | mm |
| Reading a vernier caliper | reading = A + j · r | mm |
| Micrometer Resolution | r = p / N = 0,5 / 50 = 0,01 | mm |
| Reading the Micrometer | A + M + d · 0,01 (+ v · 0,001) | mm |
| Center and Diameter with a Height Gauge | hc = (h1 + h2)/2 · D = h2 − h1 | mm |
| Rod Micrometer | D = head reading + sum of extensions | mm |
| Angled Lever Comparator | h = l · cos α | mm |
| Elongation of a block | ΔL = α · L · ΔT | mm |
| Pass/Fail Gauges | plug: P = Dmin, NP = Dmax · fork: P = dmax, NP = dmin | mm |
| Ovality and Taper | ovality = dmax − dmin in the cross section · taper = difference between the mean diameters | mm |
| Center-to-center distance | I = Le − (D1 + D2)/2 · I = Li + (D1 + D2)/2 | mm |
| Axis of a hole from the edge | x = a + D/2 · x = b − D/2 | mm |
32.16 Exercises
Exercises 1 through 8 involve reading instrument dials: look at the figure before checking the answer key. In the ninth problems, the small red triangle indicates the mark that lines up; you must find the number corresponding to that mark.
Solution
The zero mark on the vernier scale has passed the 12-mm mark (the “1” on the scale corresponds to 10 mm, plus two marks); it coincides with the fourth mark on the vernier scale: 4 × 0.1 = 0.4 mm. Reading = 12 + 0.4 = 12.4 mm.
Solution
The vernier zero is between 7 and 8 mm: A = 7 mm. The mark immediately after the number 8 aligns: 0.80 + 0.05 = 0.85 mm (seventeenth mark, 17 × 0.05 = 0.85). Reading = 7.85 mm.
Solution
The vernier zero is between 35 and 36 mm: A = 35 mm. It coincides with the third mark after the number 2: 0.20 + 3 × 0.02 = 0.26 mm (thirteenth mark, 13 × 0.02 = 0.26). Reading = 35.26 mm.
Solution
The vernier zero is just past the 52 mm mark: A = 52 mm. It coincides with the fourth mark after 0, before the number 1: 4 × 0.02 = 0.08 mm. Reading = 52.08 mm (not 52.8: the tenths place is zero).
Solution
Above the reference line, the last visible mark is 3; after 3, the half-millimeter mark is not yet visible; the reference line is at division 27 on the drum. Reading = 3 + 0.27 = 3.27 mm.
Solution
Top mark: 16 mm; the half mark is also visible below → 16.5 mm; drum at 34 → 0.34 mm. Reading = 16.5 + 0.34 = 16.84 mm.
Solution
Cylinder: 21 mm; the halfway mark is not visible → 21 mm. Drum: the reference line is between 28 and 29 → 0.28 mm. Vernier: line 3 aligns → 0.003 mm. Reading = 21 + 0.28 + 0.003 = 21.283 mm.
Solution
The tachometer needle is between 1 and 2 → 1 mm; the large index mark is at the 58 mark → 0.58 mm. The stem has retracted by 1.58 mm (clockwise: the surface has risen).
Solution
87.654: 1.004 → leaves 86.650; 1.15 → leaves 85.500; 5.5 → leaves 80; 80. So 1.004 + 1.15 + 5.5 + 80 = 87.654 (four blocks). 12.947: 1.007 → leaves 11.940; 1.44 → leaves 10.500; 10.5 is in the 112 series. So 1.007 + 1.44 + 10.5 = 12.947 (three blocks).
Solution
Gauge: PASSES 25.000 mm, FAILS 25.021 mm. Fork: PASSES 25 − 0.020 = 24.980 mm (maximum material), FAILS 25 − 0.041 = 24.959 mm.
Solution
I = 78.46 − (14.02 + 9.98) / 2 = 78.46 − 12.00 = 66.46 mm.
Solution
x = 6.35 + 12.00 / 2 = 6.35 + 6.00 = 12.35 mm. At the far edge: b = x + D/2 = 12.35 + 6.00 = 18.35 mm (that is, 6.35 + 12.00).
Solution
Ovality 1 = 25.014 − 25.006 = 0.008 mm; ovality 2 = 25.002 − 24.996 = 0.006 mm. Average diameters: 25.010 and 24.999 mm. Taper = 25.010 − 24.999 = 0.011 mm.
Solution
Clockwise: The shank is recessed; the hole is smaller than the ring. D = 50.000 − 0.012 = 49.988 mm. This is below the minimum of 50.000 mm: the hole should be discarded (or reworked, since a small hole can still be enlarged).
Solution
h = 0.050 · cos 20° = 0.050 · 0.940 = 0.047 mm: the reading is 3 µm too high.
Solution
r = 1/25 = 0.04 mm; one division is 24/25 = 0.96 mm, which is 0.04 mm less than one millimeter of the rod.
Solution
45 ± 0.02: T = 0.04 mm, uncertainty ≤ 0.004 mm → 25-50 thousandth micrometer (±0.002 to ±0.003), or a thousandth comparator zeroed on blocks. Ø60 ± 0.2: T = 0.4 mm, uncertainty ≤ 0.04 mm → a 1/50 vernier caliper or digital caliper is sufficient.
