Chapter 43

Hydraulics

Hydraulics transmits force and motion using pressurized oil. With just a few dozen bars of pressure, a small cylinder can generate forces of tens of kilonewtons, and a valve allows the speed to be adjusted with the precision of a faucet. In the workshop, we find it in the spindle chuck and tailstock of a lathe, in tool changers, in presses, in press brakes, and in construction machinery. In this chapter, we’ll start with Pascal’s principle, learn how to calculate forces, speeds, and power, familiarize ourselves with the components and their ISO 1219 symbols, and assemble them into real-world circuits.

43.1 What Is Hydraulics and Pascal's Principle?

Hydraulics transmits power through a pressurized fluid, almost always a mineral oil. A pump, driven by an electric motor, pushes the oil through the pipes; valves determine where it goes, at what pressure, and at what flow rate; hydraulic cylinders and motors convert pressure into force and flow rate into speed. It is the counterpart of pneumatics (Chapter 42), which performs the same functions using compressed air. The difference lies in the fluid: air compresses like a spring, while oil hardly compresses at all. This is why hydraulics operates at much higher pressures, generates much greater forces, and holds a load in place wherever it is left.

FeaturePneumaticsHydraulics
Fluidcompressed air, which is released into the environmentOil always flows back into the tank
Typical operating pressure6 bar30 to 350 bar
Forcesfrom a few newtons to a few kNfrom a few kN to thousands of kN
Speedhigh, but not very adjustable with the loadlower, adjustable, and constant
Stopdifficult (the air compresses)precise, even under load
Weaknessesnoise, cost of compressed airoil leaks, dirt, heat, fire hazard

On machine tools, hydraulics control the spindle clamping and the lathe tailstock, the rotation and clamping of the turret, the clamping of milling fixtures, the tool changer on many machining centers, and the balancing of the vertical axis. Then there are machines that rely almost entirely on hydraulics: presses, press brakes, shears, construction equipment, and agricultural machinery.

Pascal's Principle

In a stationary, enclosed liquid, the pressure applied at one point is transmitted equally to all points and in all directions. This is Pascal’s principle, and it alone explains why a small piston can lift a large one: the pressure is the same, but force is pressure times area, so where the area is 100 times larger, the force is also 100 times greater.

Pressure and Force Multiplication (Hydraulic Press)
p = F1A1 = F2A2 , so F2 = F1 · A2A1
F1 · s1 = F2 · s2, so s2 = s1 · A1A2
p pressure in N/mm² (1 N/mm² = 10 bar) · F1, F2 forces on the two pistons in N · A1, A2 piston areas in mm² · s1, s2 piston travels in mm. The volume of oil that exits one cylinder enters the other; therefore, the work F · s is the same on both sides (assuming no losses).
loadF₁ = 500 NF₂ = 50,000 Ns₁s₂A₁ (Ø20)A₂ (Ø200)p = 1.59 N/mm² = 15.9 bar throughout the liquidA₂ / A₁ = 100F₂ = 100 × F₁
Figure 43.1 · The hydraulic press: the same pressure acts on two different areas. The large piston exerts 100 times the force, but moves 100 times less.
Example 43.1 · The Hydraulic Press

The small piston of a press has a diameter of 20 mm and is pushed with a force of 500 N; the large piston has a diameter of 200 mm. What is the pressure in the oil, what force does the large piston exert, and how much does it rise if the small piston moves down 50 mm?

A1 = 3.1416 × 20² / 4 = 314.16 mm²; A2 = 3.1416 × 200² / 4 = 31,416 mm²
p = 500 / 314.16 = 1.592 N/mm² = 15.9 bar
F2 = p · A2 = 1.592 · 31,416 = 50,000 N (the areas are in the ratio of 100 to 1)
s2 = 50 × 314.16 / 31,416 = 0.5 mm
15.9 bar · 50,000 N (about 5 metric tons) · the large piston rises by half a millimeter
💡
The weight of the oil doesn't matter. A one-meter-high column of oil exerts a pressure of just 870 × 9.81 × 1 = 8,535 Pa on the bottom, or 0.085 bar. Compared to the 100 or 200 bar in a system, this is negligible: in hydraulics, the pressure is considered to be uniform throughout the entire fluid circuit, except for leaks in the pipes, which we will discuss in Section 43.3. It does, however, matter for the pump, which operates with less than one bar available during the suction stroke.
Example 43.2 · What pressure is needed?

A cylinder with a Ø63 piston must exert a force of 50 kN. What pressure is required (ignoring friction)?

A = 3.1416 × 63² / 4 = 3,117.2 mm²
p = F / A = 50,000 / 3,117.2 = 16.04 N/mm² = 160.4 bar
About 160 bar: a normal pressure for an industrial control unit

43.2 Pressure, Flow Rate, and Continuity

A hydraulic system is characterized by two parameters: pressure and flow rate. This is the most important concept in this chapter, and it’s best to grasp it right away: a cylinder’s force depends on pressure, and its speed depends on flow rate. The more oil that flows per minute, the faster the piston moves; the heavier the load, the higher the pressure rises.

Pressure

Pressure is measured in bar (1 bar = 100,000 Pa = 0.1 N/mm²) or in MPa (1 MPa = 10 bar = 1 N/mm²); the conversions are given in Chapter 2. A pressure gauge reads relative pressure, that is, how much higher the pressure is than atmospheric pressure: a pressure gauge reading 0 bar actually corresponds to approximately 1 bar absolute. Almost all hydraulic calculations are performed using relative pressure; absolute pressure is required only for gases in accumulators (Section 43.12).

There’s one thing that always surprises beginners: the pump doesn’t generate pressure—it generates flow. Pressure is created when the oil encounters resistance: a load to push, a restriction, or a long pipe. A pump that delivers oil through an open line back to the reservoir operates at nearly zero bar. If the cylinder reaches the end of its travel and the oil has nowhere else to go, the pressure rises until the relief valve opens (paragraph 43.9).

EmploymentApproximate operating pressure
Clamping and Machining Operations20 to 70 bar
Industrial Control Units100 to 210 bar
Presses and Bending Machines200 to 350 bar
Construction and Agricultural Machinery250 to 420 bar

The flow rate

The flow rate Q is the volume of oil that passes through a cross-section per unit of time. In the SI system, it is measured in m³/s, but in the workshop, liters per minute (L/min) are always used. If oil flows through a pipe or pushes a piston at a velocity v over an area A, in one second a “small cylinder” of oil with a length of v and a base area of A passes through:

Flow Rate
Q = A · v from which v = QA
in practical units: Q [L/min] = 6 · A [cm²] · v [m/s] = A [cm²] · v [m/min]10
Q flow rate in m³/s (or in L/min for convenience) · A cross-sectional area in m² (or in cm²) · v velocity of the oil in the pipe, or of the piston in the cylinder, in m/s. Note that 1 L = 1 dm³ = 1000 cm³ and 1 m³ = 1000 L.
Example 43.3 · How much flow rate is needed to run a cylinder?

A cylinder with an 80-mm-diameter piston must extend at a speed of 0.1 m/s (6 m/min). What flow rate is required?

A = 3.1416 · 8² / 4 = 50.27 cm² (the diameter in cm immediately gives the area in cm²)
Q = 6 × 50.27 × 0.1 = 30.16 L/min
Calculation using m/min: Q = 50.27 × 6 / 10 = 30.16 L/min
In the SI system: Q = 0.005027 m² · 0.1 m/s = 0.0005027 m³/s = 0.5027 L/s · 60 = 30.16 L/min
Q ≈ 30 L/min

The continuity equation

Oil cannot be compressed and does not accumulate anywhere: the amount that enters a section of pipe is equal to the amount that exits. If the pipe’s diameter changes, the flow rate remains the same and the velocity changes: where the cross-section narrows, the oil accelerates, where it widens and slows down. It is thecontinuity equation.

Continuity Equation
Q = A1 · v1 = A2 · v2 so v2v1 = A1A2 = d1²d2²
Velocity in a pipe: v [m/s] = 21.22 · Q [L/min]d² [mm²]
A1, A2: cross-sectional areas of the two sections · v1, v2: oil velocities in the two sections · d: inner diameter of the tube in mm. The number 21.22 is derived from 4 / (60 · π · 0.001) and accounts for all unit conversions.
d₁d₂d₁ = 20 mm · v₁ = 1.59 m/sd₂ = 12 mm · v₂ = 4.42 m/sThe same flow rate Q = 30 L/min passes through all sectionsQ = A₁ · v₁ = A₂ · v₂: where the pipe narrows, the oil accelerates
Figure 43.2 · Continuity: In the 12-mm tube, the oil flows (20/12)² = 2.78 times faster than in the 20-mm tube.
Example 43.4 · Oil Velocity in Two Pipes

A flow rate of 30 L/min first passes through a tube with an inner diameter of 20 mm and then through a 12-mm tube. What is the velocity of the oil in the two sections?

In the SI system: Q = 30 / 60,000 = 0.0005 m³/s; A20 = 3.1416 · 0.020² / 4 = 0.000314 m²
v1 = 0,0005 / 0,000314 = 1,59 m/s
using the following formula: v2 = 21.22 × 30 / 12² = 636.6 / 144 = 4.42 m/s
Continuity check: v2 = 1.59 · (20 / 12)² = 1.59 · 2.778 = 4.42 m/s
1.59 m/s in the 20-pipe and 4.42 m/s in the 12-pipe

43.3 Hydraulic Power, Pressure Drops, and Pipes

Power is work divided by time (Chapter 9). A piston with area A, driven by pressure p, exerts a force F = p · A; if it moves at velocity v, it develops power P = F · v = p · A · v. But A · v is the flow rate: the power carried by the oil is simply pressure times flow rate.

Hydraulic power
P = p · Q in practical units P [kW] = p [bar] · Q [L/min] / 600
P power in W · p pressure in Pa · Q flow rate in m³/s. Where does the 600 come from? 1 bar = 100,000 Pa and 1 L/min = 1/60,000 m³/s, so 1 bar · 1 L/min = 100,000 / 60,000 W = 1/600 kW.
Example 43.5 · The Power of a System

A pump delivers 40 L/min at 160 bar. What is the hydraulic power? Check your calculations using SI units.

P = 160 × 40 / 600 = 10.67 kW
In the SI system: p = 16,000,000 Pa; Q = 40 / 60,000 = 0.000667 m³/s; P = 16,000,000 × 0.000667 = 10,667 W
P ≈ 10.7 kW: This is the power that the oil delivers to the cylinder, before losses

Pressure drops

As the oil flows through the pipes, it rubs against the walls and against itself; in bends, fillets, filters, and valves, it changes direction and speed. All of this results in a pressure drop: pressure decreases along the circuit, and the difference is called the pressure drop Δp. The lost energy does not disappear: it is converted into heat and warms the oil, with a power loss equal to Δp · Q / 600 (in kW).

bottleneck100 bar98 bar96 bar88 bar−2 bar−2 bar−8 barStraight pipe: the pressure drops slightly and steadily; at the constriction, it drops suddenly
Figure 43.3 · Distributed (along the pipe) and concentrated (at the restriction) pressure drops. The readings are for illustrative purposes only.

Without getting into the formulas—which are a matter for engineers—it’s worth knowing what causes the losses:

  • depending on the oil velocity: when the velocity doubles, losses increase two- to four-fold, depending on the type of motion;
  • based on the length of the pipe and the number of bends, fillets, and valves;
  • due to viscosity: when the oil is cold and thick, the losses are much higher (paragraph 43.4);
  • Diameter: A smaller tube means higher speed and greater friction.

The type of flow is determined by the Reynolds number Re = v · d / ν, where ν is the kinematic viscosity of the oil. Below approximately 2300, the flow is laminar (the oil flows in orderly layers, and losses increase with velocity); above that, it is turbulent (vortices, losses that increase with the square of the velocity, and more noise). In properly sized hydraulic lines, the flow typically remains laminar or just above the laminar threshold.

Recommended Speeds and Pipe Diameters

To minimize losses and heat, the oil in the pipes must not travel too quickly. The most sensitive section is thesuction of the pump: there, the available thrust is only atmospheric pressure, and if the oil has to accelerate too much, the pressure drops to the point where vapor bubbles form (cavitation, paragraph 43.14). In the sent, at high pressure, you can run faster; in the return the middle ground.

Section of the circuitRecommended Speed (Approximate)
Pump Suctionfrom 0.5 to 1.2 m/s
Back to the tank2 to 4 m/s
Delivery pressure up to 100 bar3 to 4 m/s
Delivery pressure: 100 to 200 bar4 to 5 m/s
Pressure exceeding 200 bar5 to 6 m/s

By reversing the velocity formula, you can determine the minimum inner diameter of the pipe; then, select the first commercially available diameter that is equal to or greater than that value and recheck the velocity.

Inner diameter of a tube
d [mm] = √21.22 · Q [L/min]v [m/s]
d minimum internal diameter in mm · Q flow rate in the pipe in L/min · v recommended velocity in m/s (from the table). Note: The flow rate in a cylinder’s return line may be greater than that of the pump (paragraph 43.7).
Example 43.6 · Sizing the Pipes for a Control Unit

A control unit delivers 60 L/min at 150 bar. Select the inside diameter of the suction (1 m/s), discharge (5 m/s), and return (3 m/s) pipes, with available inside diameters of 16, 20, 25, 32, and 40 mm. Then check the flow in the delivery line with oil at 46 mm²/s.

Suction: d = √(21.22 × 60 / 1) = √1273 = 35.7 mm → 40 mm is chosen; v = 21.22 × 60 / 40² = 0.80 m/s
Output: d = √(21.22 × 60 / 5) = √254.6 = 15.96 mm → 16 mm; v = 21.22 × 60 / 16² = 4.97 m/s
Return: d = √(21.22 × 60 / 3) = √424.4 = 20.6 mm → 25 mm; v = 21.22 × 60 / 25² = 2.04 m/s
Reynolds number in the flow: Re = v · d / ν = 4970 mm/s · 16 mm / 46 mm²/s = 1729 < 2300 → laminar flow
Suction 40 mm, discharge 16 mm, return 25 mm: the suction hose is the largest of them all

43.4 Hydraulic Oil

Oil isn't just for transmitting pressure. It must also lubricate pumps, valves, and seals; dissipate the heat generated by leaks; protect against rust; and carry debris to the filters. That’s why you can’t just use any oil: specially formulated oils are used, identified by standardized codes.

  • HL: mineral oil with rust inhibitors and antioxidants, for lightly loaded systems;
  • HLP: like HL but with additional anti-wear additives; it is the most widely used oil in industrial power units and tool machines;
  • HVLP: HLP with a high viscosity index, meaning its viscosity changes less with temperature; it is used outdoors and in places where temperatures vary greatly;
  • fire-resistant fluids (abbreviations: HFA, HFC, HFD): water and glycol or synthetic esters, where there is a fire hazard, such as near furnaces and die-casting presses;
  • Biodegradable fluids (e.g., HEES, ester-based): for agricultural, forestry, and construction machinery used near water.

Viscosity and ISO VG Classes

Viscosity indicates how “thick” a liquid is—that is, how much resistance it offers to flow. For oils, kinematic viscosity ν is used, measured in mm²/s (also called centistokes, cSt). Viscosity decreases significantly with temperature: cold oil is as thick as honey, while hot oil flows like water. To enable comparison of oils, the ISO 3448 standard classifies them into ISO VG grades: the number represents the average viscosity at 40 °C, with a tolerance of ±10%.

ClassViscosity at 40 °C (mm²/s)Typical Use (for reference)
ISO VG 22from 19.8 to 24.2precision circuits, servo valves, cold environments
ISO VG 32from 28.8 to 35.2machine tools, indoor control units
ISO VG 46from 41.4 to 50.6the most commonly used class in industrial control units
ISO VG 68from 61.2 to 74.8hot systems, presses, high pressures
ISO VG 100from 90 to 110Very hot systems, slow pumps
Recommended operating range: 16–36 mm²/s51020501002005001,000020406080100ISO VG 32ISO VG 46ISO VG 6840 °C: this is the temperature at which the class is measuredTemperature (°C)viscosity (mm²/s), logarithmic scale
Figure 43.4 · How viscosity decreases with temperature for three mineral oils with a normal viscosity index (indicative curves). The green band represents the range in which the pumps operate most efficiently.

Oil that is too viscous (cold, or of too high a grade) increases leakage, generates heat, has difficulty entering the pump, and causes cavitation. Oil that is too thin (hot, or of too low a viscosity grade) fails to lubricate, leaks through the seals, and reduces the pump’s volumetric efficiency. Each manufacturer specifies the permissible viscosity range; as a general rule, pumps operate well between 16 and 36 mm²/s and can withstand a few hundred mm²/s during cold starts.

Example 43.7 · Which Oil for Which Temperature

A control unit operates at full capacity with oil at 50 °C. Referring to Figure 43.4 (curves calculated for a viscosity index of approximately 100), what viscosity class does the viscosity fall into in the range from 16 to 36 mm²/s?

ISO VG 32: remains within the range of approximately 37 to 58 °C → at 50 °C, it is approximately 21.5 mm²/s
ISO VG 46: remains within the range of approximately 46 to 68 °C → at 50 °C, it is approximately 30 mm²/s
ISO VG 68: remains within the range of approximately 54 to 77 °C → at 50 °C, it is approximately 43 mm²/s, which is too thick
At startup at 20 °C, the ISO VG 46 viscosity is approximately 134 mm²/s: the pump can draw it in, but it is best to let the system warm up before operating at full pressure
Both 32 and 46 are fine; 46 leaves more margin if the oil reaches 60 °C in the summer

The temperature

The proper operating temperature for the oil is between approximately 40 and 55 °C. Above 60 °C, the oil degrades rapidly: as a rule of thumb, for every 10 °C increase, its service life is cut in half, because oxygen in the air oxidizes it and forms sludge and varnish that cause valves to stick. Temperatures above 70–80 °C also damage the seals. For this reason, the control units have a thermometer on the reservoir and, when heat loss is high, an air-to-oil or water-to-oil heat exchanger.

Filtration and Cleanliness Classes

Dirt is the number one enemy of hydraulic systems: the parts of pumps and valves operate with clearances of just a few micrometers (1 µm = 0.001 mm), and any particle larger than the clearance will cause scoring, sticking, or blocking. Chips and dust enter the oil during assembly, along with wear particles and dust from the air through the tank vent. Filters are located in three positions:

  • on the suction side: a coarse screen (60 to 150 µm) that protects the pump from large workpieces without impeding suction;
  • In the supply line: a high-pressure, fine filter (3 to 10 µm) installed upstream of the most delicate valves, such as servo valves;
  • On the return line: the main filter (10 to 25 µm), which cleans all the oil before it returns to the reservoir; it has an indicator that alerts you when it is clogged.

Oil purity is expressed by the ISO Class 4406, three numbers such as 18/16/13 that indicate, in code, how many particles larger than 4, 6, and 14 µm are present in one milliliter of oil. Each lower number means about half as many particles. As a rough guide (indicative values): 19/17/14 for gear pumps and simple systems, 18/16/13 for vane and piston pumps, 17/15/12 for proportional valves, 16/14/11 for servo valves. Also, thewater Dirt in the oil makes it milky, causes rust, and ruins the additives.

43.5 The Hydraulic Control Unit

The control unit is the heart of the system: it pressurizes the oil and receives it back. Its components are always the same, even if their shape and size vary.

  • Reservoir: It holds the oil, allowing it to settle so that air rises and impurities sink, and dissipates some of the heat. As a rule of thumb, it holds 3 to 5 times the pump’s flow rate per minute. A partition separates the return zone from the suction zone, so that the hot, agitated oil circulates once before being drawn back in.
  • An electric motor and a pump, connected by a flexible coupling inside a housing that keeps them aligned.
  • Suction filter, return filter, and fill plug with air filter (the vent: the oil level rises and falls as the cylinders extend and retract, and the air entering must be clean).
  • Pressure relief valve: sets the maximum system pressure and protects the system (paragraph 43.9).
  • Pressure gauge, usually equipped with a valve or button to shut it off so it doesn't vibrate constantly.
  • A level gauge and thermometer, often in a single workpiece; sometimes a thermostat and a low-level switch that shut down the machine if the oil gets too hot or the level drops too low.
  • Heat exchanger, when the heat produced exceeds the amount the tank can dissipate.
P: to the carT: returnelectric motorheadlight and couplingpressure gaugepressure relief valvepumpsuction filtercap with air filterreturn filterheat exchangerair-oillevel indicatorseparator platetank
Figure 43.5 · A hydraulic power unit. The pump is submerged in oil beneath the cover; the return oil passes through the filter and the heat exchanger before returning to the reservoir.

In drawings, the control unit is drawn using the symbols specified in ISO 1219, the same standard as the pneumatic symbols in Chapter 42. There are only a few differences to keep in mind: in hydraulics, the triangles representing pumps and motors are filled in (in pneumatics, they are empty), and each return line ends at the reservoir symbol, which can be repeated as many times as needed in the same diagram. Pilot and drain lines are shown as dashed lines.

MPpressure gaugeelectric motorfixed-displacement pumpsuction filtertankadjustable spring (calibration)pressure relief valvedischarge to the reservoir
Figure 43.6 · The control unit as shown in ISO 1219 symbols. The dashed line represents the control line: it carries the inlet pressure to the pressure limiter. In this chapter, we will use this same configuration in all circuits, with the P outlet at the top.

43.6 Pumps

Hydraulic pumps are volumetric: with each revolution, they seal off a certain volume of oil on the suction side and push it to the discharge side. This volume is called the displacement V and is measured in cm³/revolution. A positive-displacement pump delivers its flow rate regardless of pressure: if the discharge line is blocked, the pressure rises until something gives way. For this reason, a relief valve is always essential.

suctiondischargeto external gearsanddischargesuctionvanesinclined platecylinder blockpistonsαaxial piston
Figure 43.7 · The three main types. Gear-type: the oil flows in the spaces between the teeth, along the wall. Vane-type: the chambers between the vanes expand and contract due to the eccentricity e. Axial piston-type: the travels of the pistons depend on the angle α of the plate.
  • External gear pumps: two identical gears, one driving and one driven. Oil enters where the teeth separate, flows through the spaces between the teeth along the body wall, and exits where the teeth mesh again. Simple, sturdy, and economical, but somewhat noisy; fixed displacement. Internal-gear versions are much quieter and are often used in machine tools.
  • Vane pumps: A rotor with sliding vanes rotates inside an eccentric ring; the chambers between the vanes widen on the suction side and narrow on the discharge side. They are quiet and provide a steady flow rate. If the ring can be moved, the eccentricity changes, and so does the displacement: this is a variable-displacement vane pump, often equipped with a pressure compensator that reduces the flow rate when the pressure reaches the set point.
  • Piston pumps: multiple pistons slide within a rotating cylinder block. In axial pumps, the pistons rest on an inclined plate: the steeper the incline, the longer the travels and the greater the displacement; when the plate is vertical, the flow rate is zero. There are also radial pumps, with pistons arranged in a radial pattern. These are the pumps that deliver the highest pressures and best efficiency, but they cost more and require clean oil.
TypeMaximum pressure (approximate)DisplacementNotes
External-gear200 to 280 barfixedinexpensive, sturdy, noisy
Internal-gear250 to 350 barfixedquiet, tools
A palette100 to 210 barfixed or variableQuiet, smooth operation
Axial-piston280 to 420 barfixed or variableHigh-performance, mobile presses and machines

In drawings, pumps, motors, and cylinders are drawn using the symbols shown in Figure 43.8. A diagonal arrow crossing a symbol always means “adjustable”: on a pump, it indicates variable displacement; on a valve spring, it indicates adjustment.

fixed-displacementfixed-displacementpump withvariable displacementhydraulic motor(single-acting)Melectricelectricsingle-actingsingle-actingdouble-acting cylinder(differential)reservoirfilterheat exchanger(cooler)pressure gaugeaccumulator
Figure 43.8 · The ISO 1219 symbols for the main components. In hydraulics, the triangles are filled; in pneumatics (Chapter 42), they are empty.

Flow Rate, Efficiency, and Engine Power

Multiplying the displacement by the rotational speed yields the theoretical flow rate. In reality, some oil leaks internally, from the discharge side to the suction side, and the higher the pressure, the greater the leakage: this is accounted for by the volumetric efficiency ηv. Then there are mechanical and hydraulic frictions, which require the engine to produce more torque than necessary: the hydraulic-mechanical efficiency ηhm. The product of the two is the total efficiency ηt, as shown in the efficiency chain in Chapter 9.

Pump Flow Rate and Electric Motor Power
Q = V · n · ηv1000 Pm = p · Q600 · ηt ηt = ηv · ηhm
Q Actual flow rate in L/min · V displacement in cm³/rev · n pump speed in rpm · ηv volumetric efficiency (0.85 to 0.95 for gears and vanes, 0.93 to 0.97 for pistons) · Pm power that the electric motor must deliver in kW · p pressure in bar · ηt Total efficiency (from 0.75 to 0.90). The number 1,000 converts cm³ to liters.
Example 43.8 · Gear Pump and Electric Motor

A gear pump with a displacement of 16 cm³ per revolution is driven by a 4-pole motor rotating at 1,450 rpm. The volumetric efficiency is 0.93 and the total efficiency is 0.85. What is the flow rate? What power does the motor need if the system operates at 150 bar?

Q = 16 × 1450 × 0.93 / 1000 = 21.58 L/min (the theoretical value would be 23.2 L/min)
hydraulic power: 150 × 21.58 / 600 = 5.39 kW
Pm = 5.39 / 0.85 = 6.35 kW
Q ≈ 21.6 L/min; a 6.35 kW motor is required, so the first one listed in the catalog above: 7.5 kW
Example 43.9 · Which Displacement to Choose

A flow rate of 40 L/min is required with a motor running at 1,450 rpm; ηv is estimated to be 0.92. What displacement is needed? The catalog lists pumps with displacements of 25, 32, and 40 cm³/rev.

From the derived formula: V = 1,000 · Q / (n · ηv) = 40,000 / (1,450 · 0.92) = 40,000 / 1,334 = 29.99 cm³/revolution
Choose 32: Q = 32 × 1450 × 0.92 / 1000 = 42.69 L/min
A pump with a displacement of 32 cm³ per revolution, which delivers approximately 42.7 L/min
⚡
Why variable-displacement pumps are used. A fixed-displacement pump always delivers its full flow rate: when the cylinder is at rest, all the oil passes through the pressure relief valve at maximum pressure, and the power is converted into heat (example 43.13). A variable-displacement pump with a compensator, once it reaches the set pressure, automatically reduces its displacement until it delivers only the oil needed to compensate for leaks: it maintains pressure with almost no energy consumption. It costs more to purchase but saves on energy and heat exchangers.

43.7 The Cylinders

The cylinder converts oil pressure into a force along a straight line. It consists of a barrel sealed by two end caps, a piston with its seals, a chrome-plated rod that extends from one end cap through a seal, and a rod scraper that cleans the rod as it retracts. Many cylinders have end-of-stroke dampers: in the final millimeters, the outgoing oil is forced to pass through a small hole, slowing the piston before it strikes the end cap.

  • Single-acting: the oil pushes in one direction only; the return is provided by a spring or the weight of the load (lifts, jacks, simple clamps).
  • Double-acting: the oil pushes in both directions, entering once from one side and once from the other.
  • Differential: This is the most common type of double-acting cylinder, with the piston rod on only one side. The two areas against which the oil exerts force are different, so the forces and speeds during extension and retraction are different.
  • Double-rod: the rod passes through both sides; the cross-sectional areas are equal, and the cylinder moves the same way in both directions (steering, boards).
  • Telescopic: multiple sections nested inside one another, for long travels with a compact footprint (folding).
ABDdchamber at the rear endArea A₁ = π · D² / 4chamber on the stem sidecrown: A₂ = π · (D² − d²) / 4F₁thrust: oil enters A and pushes on A₁, exits through B → F₁ = p · A₁ and v₁ = Q / A₁Return: The oil enters B and exerts a force on the crown A₂ → F₂ = p · A₂ and v₂ = Q / A₂
Figure 43.9 · The differential cylinder: during the forward stroke, the oil acts on the entire piston (A₁); during the return stroke, it acts only on the circular ring around the rod (A₂).
The Differential Cylinder
A1 = π · D²4 A2 = π · (D² − d²)4 φ = A1A2
thrust: F1 = p · A1 · ηm v1 = QA1 return: F2 = p · A2 · ηm v2 = QA2
D piston diameter · d rod diameter · A1 piston area (bottom side) · A2 crown area (rod side) · φ area ratio · p pressure · Q flow rate entering the cylinder · ηm mechanical efficiency of the cylinder, ranging from 0.90 to 0.95, due to seal friction (in rough calculations, it is assumed to be equal to 1). When p is in N/mm² and areas are in mm², the force is in N; when Q is in mm³/s, the velocity is in mm/s.

There is one surprising fact: On the return stroke, the cylinder moves faster and exerts less force, because the same flow rate fills a smaller volume. And the oil that comes out of the bottom during the return stroke is more of the flow rate delivered by the pump: φ times that amount. Pipes, filters, and valves on the return line must be sized for this flow rate, not for the pump's flow rate.

Example 43.10 · Forces and Velocities of a Differential Cylinder

A cylinder with a diameter of 63 and a rod diameter of 36 is supplied with 20 L/min at 100 bar. Calculate the forces and velocities during the extension and retraction strokes (with ηm = 1) and the flow rate exiting the cylinder in both cases.

A1 = 3.1416 × 63² / 4 = 3,117.2 mm²; cross-sectional area of the stem = 3.1416 × 36² / 4 = 1,017.9 mm²
A2 = 3117.2 − 1017.9 = 2099.4 mm²; φ = 3117.2 / 2099.4 = 1.485
p = 100 bar = 10 N/mm² → F1 = 10 · 3117.2 = 31,172 N ≈ 31.2 kN; F2 = 10 × 2099.4 = 20,994 N ≈ 21.0 kN
Q = 20 L/min = 20,000,000 mm³ / 60 s = 333,333 mm³/s
v1 = 333,333 / 3,117.2 = 106.9 mm/s (6.42 m/min); v2 = 333,333 / 2,099.4 = 158.8 mm/s (9.53 m/min)
In the forward stroke, fluid exits from the rod side: 20 / 1.485 = 13.47 L/min; in the return stroke, fluid exits from the end cap side: 20 · 1.485 = 29.70 L/min
Forward thrust: 31.2 kN at 6.4 m/min; return thrust: 21.0 kN at 9.5 m/min; nearly 30 L/min flows back to the reservoir via a 20 pump

The Regenerative Connection

If the two chambers of the differential cylinder are connected to each other and to the pump, the pressure is the same on both sides of the piston. The forces acting on the two faces cancel each other out, except for the force on the rod area, which has no corresponding force: the cylinder extends with a small force. Instead, the oil exiting the rod side does not return to the reservoir but flows back into the end cap side and combines with the oil from the pump, causing the cylinder to extend. This is the regenerative connection: it is used for rapid approach, when there is no load yet, and then the system switches to the normal connection for the travel.

Regenerative connection
Fr = p · As vr = QAs As = π · d²4
Fr Output power in regenerative mode · vr output speed · As cross-sectional area of the stem · d rod diameter. Since the rod has half the cross-sectional area of the piston (φ = 2), the extension and regenerative retraction occur at the same speed.
Cylinder Ø63/36Min A: 61.25 L/minfrom the pump: 20 L/minfrom the rod: 41.25 L/minThe two chambers are connected:only the rod area is pushed,but the oil exiting the rod sidereturns to the bottom side.F = p · A (rod)v = Q / A (rod)
Figure 43.10 · Schematic diagram of the regenerative connection, showing the flow rates from Example 43.11. In actual circuits, a directional control valve switches between the normal and regenerative connections.
Example 43.11 · The Same Cylinder in Regenerative Mode

The cylinder from Example 43.10 (Ø63/36, 20 L/min, 100 bar) is connected in a regenerative configuration for the approach. What are the force, speed, and flow rates?

Fr = 10 · 10¹⁷.⁹ = 10,179 N ≈ 10.2 kN
vr = 333,333 / 1,017.9 = 327.5 mm/s = 19.6 m/min
oil flowing out of the rod side: 327.5 × 2099.4 = 687,500 mm³/s = 41.25 L/min
Oil flow into the bottom port: 20 + 41.25 = 61.25 L/min (verification: 327.5 × 3,117.2 × 60 / 1,000,000 = 61.25 L/min)
The cylinder extends three times faster (19.6 instead of 6.4 m/min) with one-third of the force (10.2 instead of 31.2 kN)
⚠️
The rod is subjected to a peak load. A long, thin rod under thrust can suddenly bend, like a column loaded at its top. The verification follows the tip load analysis in Chapter 10: Example 10.21 specifically shows that a Ø25 rod, 800 mm long, is insufficient for a Ø50 cylinder operating at 100 bar. Cylinder catalogs include tables listing the maximum allowable travel for each rod and each type of mounting.

43.8 Hydraulic Motors

A hydraulic motor is a pump that works in reverse: it receives pressurized oil and produces rotating shafts. The design principles are the same as those of pumps (gear, vane, axial-piston, and radial-piston), plus compact orbital (or gerotor) motors, which rotate smoothly and deliver high torque. Hydraulic motors are used where high torque at low speeds, starting under load, and frequent direction changes are required: winches, conveyors, screw conveyors, winders, wheels on mobile machinery, tool magazines, and mixers.

Displacement determines everything: with each revolution, the engine “swallows” its volume V, so the revolutions depend on the flow rate; torque is the work done by the oil in one revolution, Δp · V, divided by the angle of one revolution, 2π.

Hydraulic motor
M = V · Δp / (2π · ηhm ); in practice, M [N·m] = V [cm³] · Δp [bar] / (20π · ηhm)
n = 1000 · Q · ηvV P = M · ω = Δp · Q600 · ηt
M torque at the shaft in N·m · V displacement in m³ (or in cm³ for practical purposes) · Δp pressure difference between the motor's inlet and outlet, in Pa (or bar) · n revolutions per minute · Q flow rate in L/min · ηhm, ηv, ηt Hydraulic-mechanical, volumetric, and total efficiency · ω angular velocity in rad/s. The value 20π comes from 1 cm³ · 1 bar = 0.000001 m³ · 100,000 Pa = 0.1 J.
Example 43.12 · Torque, RPM, and Power of a Hydraulic Motor

A 100 cm³/rev hydraulic motor receives 40 L/min with a pressure difference of 150 bar. Calculate the theoretical torque, speed, and power, then the actual values with ηhm = 0.90 and ηv = 0.95.

In the SI system: M = 0.0001 m³ · 15,000,000 Pa / (2 · 3.1416) = 1,500 / 6.2832 = 238.7 N·m
In practice: M = 100 × 150 / 62.83 = 238.7 N·m
n = 1000 × 40 / 100 = 400 rpm
P = M · ω = 238.7 · (2 × 3.1416 × 400 / 60) = 238.7 × 41.89 = 10,000 W; check: 150 × 40 / 600 = 10 kW
Actual values: M = 238.7 × 0.90 = 214.9 N·m; n = 400 × 0.95 = 380 rpm
Rated: 238.7 N·m, 400 rpm, 10 kW; actual: approximately 215 N·m at 380 rpm

To reverse the direction of rotation, simply swap the inlet and outlet using a directional control valve. A stationary hydraulic motor, however, does not hold the load like a brake: oil seeps through it, and the load descends slowly. A mechanical brake is installed on winches, which opens under pressure.

43.9 Pressure Valves

Pressure valves compare the oil pressure to the force of a spring. The spring is adjusted with a screw: this is the calibration. In symbols, they are identified by a single square with an arrow, an adjustable spring on one side, and a dashed pilot line on the other; the pilot line indicates the pressure the valve “senses.”

P (from the pump)T(to the tank)shutterspringadjustment screwTPlimiter(closed at rest)APsequence(closed, drain)APreducing valve(open at rest)ISO 1219 symbolsP inlet · A, T outlet
Figure 43.11 · On the left is a direct-acting pressure relief valve: when the pressure at P overcomes the spring force, the spool lifts, and oil flows to T. On the right are the symbols for the three pressure valves.

The Relief Valve

The pressure relief valve (or maximum pressure valve) is closed in its normal state and senses the pressure at its inlet. When the pressure exceeds the set point, it opens and diverts as much oil as necessary to the reservoir to prevent the pressure from rising further. It serves as the system’s safety valve and is always located immediately after the pump. Small relief valves are direct-acting, like the one shown in the figure; for high flow rates, pilot-operated valves are used, in which a small direct-acting valve controls a large spool: they are more precise, and the pressure increases less as the flow rate rises.

All the oil that passes through the pressure-limiting valve drops from the set pressure to the tank pressure without performing any work: all of its energy is converted into heat. As a rule of thumb, the oil heats up by about 0.6 °C for every 10 bar drop in pressure.

Example 43.13 · The Heat of the Limiter

A fixed 30 L/min pump operates with the pressure relief valve set to 120 bar. The cylinder remains stationary, locked, for most of the cycle, and during that time all the oil passes through the pressure relief valve. How much power is converted into heat? By how much does the oil heat up with each pass (density 870 kg/m³, specific heat 1900 J/(kg·K))?

P = 120 × 30 / 600 = 6 kW, all as heat
oil mass per second: 870 · 30 / 60,000 = 0.435 kg/s
ΔT = P / (mass per second · specific heat) = 6000 / (0.435 · 1900) = 7.3 °C
using the rule of thumb: 120 bar / 10 × 0.6 = 7.2 °C
6 kW of heat, like a large stove: the oil heats up by more than 7 °C with each pass, and without a heat exchanger, the temperature rises quickly

The pressure-reducing valve

The pressure-reducing valve is open in its normal state and senses the pressure at its outlet. When this pressure reaches the set point, the valve closes just enough to keep it constant, regardless of the upstream pressure (which must be higher). It is used when a branch of the circuit must operate at a lower pressure than the rest: clamping a thin workpiece, the lathe spindle, or a cylinder that must not apply pressure. It has an external drain (shown as a dotted line) that returns the oil leaking from the spring side to the reservoir.

Example 43.14 · Calibrating a Gearbox

A 150-bar control unit also powers a Ø40 clamping cylinder, which must not exceed 8 kN to prevent deformation of the workpiece. At what pressure should the pressure reducer be set on its branch?

A = 3.1416 × 40² / 4 = 1,256.6 mm²
p = 8000 / 1256.6 = 6.37 N/mm² = 63.7 bar
Pressure regulator set to approximately 63 bar (slightly lower, to be on the safe side): the cylinder clamps with 8 kN even though the control unit is set to 150 bar

The Sequence Valve

The sequence valve is similar to a pressure-limiting valve: it is closed in the rest position and opens when the pressure at its inlet exceeds the set pressure. The difference is that its outlet does not lead to the reservoir but to another branch of the circuit, which thus remains without oil until the first branch has reached the desired pressure. It is used to perform two movements one after the other without the need for electrical signals: first, the workpiece is blocked, and only when the blocking mechanism has reached the set pressure does the machining begin (Figure 43.19). Since the outlet is under pressure, the sequence valve also has its own external drain.

A close relative of this sequence is the counterbalance valve: it is located in the line of a vertical cylinder and maintains oil pressure beneath the piston, so that the weight of the load does not cause it to drop when the directional control valve opens the outlet. We’ll see it in the press (Figure 43.20). Finally, the pressure switch doesn’t regulate anything: it senses pressure and closes an electrical contact when it reaches the set value, to give the go-ahead to the PLC or the numerical control system.

43.10 Distributors and Check Valves

The valves determine where the oil goes: they direct it to one chamber or the other of the cylinder, or they block it. The symbols are the same as those used in pneumatics and are explained in Chapter 42: each box represents a position, the arrows inside the box indicate the flow paths, the letters denote the lines (P for supply, T for reservoir, A and B for loads), and the control symbols are shown at the ends. In hydraulics, the most commonly used valve is the 4/3-way valve: four ports, three positions, two solenoids (Y1 and Y2), and two springs that return it to the center position when neither solenoid is energized.

The side squares are almost always the same: in one, P goes to A and B goes to T (the parallel arrows); in the other, P goes to B and A goes to T (the crossed arrows). What changes is the center cell—the resting position—and the choice of center determines how the machine behaves when it is at rest.

ABPTDowntown ClosedAll streets blockedABPTDowntown openAll connected streetsABPTTandem CenterP with T, A, and B lockedABPTfloating centerP locked, A and B with T
Figure 43.12 · The four most common positions of the 4/3-way valve with two solenoids and spring-return centering.
CenterWhat does it do when it's idle?When to use
Closedblocks all lines: the cylinder remains stationary, and the pump remains pressurizedmultiple outlets on the same pump; systems with a variable-displacement pump or a pressure tank
OpenConnect everything to the tank: the pump is discharging, the cylinder is freeSimple circuits with a single actuator; motors that must come to a stop by inertia
TandemConnect P to T and lock A and B: the pump discharges with almost no pressure, and the cylinder remains stationarypresses and machines with fixed pumps, to prevent the oil from heating up when idle
FloatingLock P and connect A and B to T: the cylinder moves manually, and the pump remains pressurizedwith piloted check valves (the pilot lines are vented); motors running freely

Small electric valves have standard connections in accordance with ISO 4401 (the sizes still referred to in workshops as CETOP 3 and CETOP 5) and are mounted on plates or blocks that carry the channels. For high flow rates, the solenoid would not have enough force to move the spool; pilot-operated valves are used instead, in which a small solenoid valve sends pilot oil to move the main spool.

Check Valves

The check valve allows oil to pass in one direction and blocks it in the other: a ball or a conical plug is pushed against its seat by the pressure coming from the wrong side (and often by a light spring). In the symbol, the ball is represented by the small circle and the seat by the “V”: the oil flows through when it enters from the tip of the “V” and lifts the ball.

The piloted check valve has an additional piston that, when it receives pressurized oil from pilot line X, lifts the ball and opens the passage even in the blocked direction. Two pilot-operated check valves, one mounted on line A and one on line B with cross-piloted connections, form the hydraulic block: the cylinder remains stationary even under load and even if the directional control valve leaks, because the ball valves close without leakage (Figure 43.18). To move the ball, the piston has a larger cross-sectional area than the seat; the ratio between the two is called the pilot ratio and is typically between 3 and 4.

No Returnno returnpilotedXchokefixedthrottling valveadjustableregulatorone-wayregulatorcompensated
Figure 43.13 · ISO 1219 symbols for check valves (free flow in the direction of the red arrow), pilot-operated check valves, and flow regulators as described in paragraph 43.11.

Proportional Valves and Servo Valves

A standard valve is either fully open or fully closed. In proportional valves, the solenoid is designed so that the force is proportional to the current: a control circuit sends a current ranging from 0 to the maximum, and the spool opens by that amount. Thus, using an electrical signal (for example, from 0 to 10 V), the speed, acceleration, and braking of a cylinder can be controlled with smooth transitions. There are also proportional pressure limiters and reducers, which adjust the pressure according to a program.

Servovalves perform the same function with much greater precision and response speed: a torque motor moves a pilot stage, and the main spool has a transducer that controls its position in a closed-loop system. With a position sensor on the cylinder, a true controlled hydraulic axis is created, similar to the electric axes described in Chapter 48: this is the case with CNC bending machines and presses. The trade-off is the oil: servo valves require ultra-fine filtration (class 16/14/11 or better).

43.11 Flow Regulators

The speed of a cylinder or motor is controlled by adjusting the flow rate entering (or exiting) it. The simplest device is the throttle: a narrow passage, either fixed or adjustable with a screw. Its limitation is that the flow rate it allows depends on the pressure difference across it and on viscosity: if the load changes, or the oil heats up, the speed changes. The compensated regulator solves this problem with a small valve—the compensator—which keeps the pressure drop across the orifice constant: the flow rate remains at the set value regardless of the load. The unidirectional regulator has a check valve connected in parallel: it regulates flow in one direction and allows free passage in the other, thus controlling the desired forward travel without slowing down the return travel.

The regulator can be set to three different positions, and each one behaves differently.

incomingoutputbranch
Figure 43.14 · Adjustment of the thrust travel (red arrow): inlet, outlet, and bypass. For clarity, the directional control valve is not drawn.
  • Inlet (meter-in): The regulator meters the oil entering the cylinder; any excess oil returns to the reservoir via the restrictor. This works well with loads that oppose the direction of motion (pushing, drilling, tightening). It does not work well with loads that pull in the direction of motion (a weight descending): the piston would move forward faster than the oil could arrive, leaving a vacuum in the chamber.
  • Outlet (meter-out): The regulator throttles the outgoing oil flow. The piston is confined between two columns of oil and moves more smoothly, even under pulling loads: this is the most commonly used solution on machine tools. Be careful, however: the pressure in the rod chamber can become higher than that of the pump (e.g., 43.15).
  • In the branch line (bleed-off): The regulator diverts part of the pump's flow to the reservoir, and the rest goes to the cylinder. The pump operates only at the pressure required by the load, not at the pressure of the relief valve: this results in less oil heating. In return, the regulation is less precise, because the pump’s leakage varies with pressure.
Example 43.15 · Speed with the regulator and pressure on the rod side

A Ø50 cylinder with a Ø32 rod must extend slowly. With the inlet regulator set to 5 L/min, at what speed does it extend? With an outlet regulator also set to 5 L/min (on the oil exiting the rod side)? In the second case, if the cylinder is running unloaded with the pump at 100 bar, what pressure builds up on the rod side?

A1 = 3.1416 × 50² / 4 = 1,963.5 mm²; stem 3.1416 × 32² / 4 = 804.2 mm²; A2 = 1963.5 − 804.2 = 1159.3 mm²
Q = 5 L/min = 5,000,000 / 60 = 83,333 mm³/s
Input: v = 83,333 / 1,963.5 = 42.4 mm/s
Outlet: The regulated flow rate is the one exiting the stem side → v = 83,333 / 1,159.3 = 71.9 mm/s
At idle, the forces on the piston are in equilibrium: p2 · A2 = p1 · A1 → p2 = 100 · 1963.5 / 1159.3 = 169.4 bar
42.4 mm/s at the inlet, 71.9 mm/s at the outlet (same calibration, different speeds); 169 bar on the rod side with a 100 pump: the hoses and seals in that chamber must be able to withstand these pressures

43.12 Batteries

The accumulator is a container that holds oil under pressure and ready for use, just as a battery holds a charge. Inside is a gas—nitrogen—separated from the oil by a rubber bladder, a diaphragm, or a piston. When the pump delivers oil, the gas is compressed; when the system demands more oil than the pump can supply, the gas expands and forces the oil out.

nitrogenoilinflation valveto the systembagnitrogenoildiaphragmmembranesymbol(gas-powered)
Figure 43.15 · Bladder-type accumulator (long cylinder, volumes from 1 to 50 liters) and diaphragm-type accumulator (spherical, small volumes). Nitrogen is shown in light blue; oil is shown in yellow.

There are many uses:

  • energy reserve: a small pump charges the accumulator during pauses, and during rapid movements, the pump and accumulator work together;
  • Pressure maintenance: A lock remains engaged when the pump is off, because the accumulator compensates for small leaks;
  • Emergency: If the power goes out, the stored oil is sufficient to return a cylinder to a safe position;
  • Damping: Absorbs water hammer and pump pulsations.

To calculate how much oil a accumulator holds, Boyle’s law is used: at a constant temperature, the pressure per unit volume of a gas remains constant. Pressures must be expressed in absolute terms, that is, the pressure reading on the pressure gauge plus 1 bar. The gas is charged at the factory to a precharge pressure p0 when the accumulator is empty of oil; for bladder-type accumulators, p0 is usually set to ≈ 0.9 · p1, so that the bladder never strikes the bottom valve.

Boyle's Law and the Useful Volume of the Accumulator
p0 · V0 = p1 · V1 = p2 · V2 ΔV = V1 − V2 = p0 · V0 · (1p1 − 1p2)
p0 precharge pressure (absolute) · V0 gas volume at vacuum, i.e., the nominal volume of the accumulator · p1, p2 minimum and maximum absolute operating pressures · V1, V2 gas volumes at the two pressures · ΔV oil returned by the accumulator as it transitions from p2 to p1. This formula applies to slow (isothermal) processes; if the accumulator discharges in a few seconds, the gas cools and the effective volume is slightly smaller.
Example 43.16 · The effective volume of a storage tank

A 10-liter bladder accumulator is precharged to 90 bar. The system operates between 100 and 160 bar (pressure gauge readings). How much oil does the accumulator release as the pressure drops from 160 to 100 bar?

Absolute pressures: p0 = 91 bar, p1 = 101 bar, p2 = 161 bar
V1 = 91 × 10 / 101 = 9.01 L (at 100 bar, there is just 1 L of oil inside)
V2 = 91 × 10 / 161 = 5.65 L (at 160 bar, the oil volume is 10 − 5.65 = 4.35 L)
ΔV = 9,01 − 5,65 = 3,36 L
The storage tank holds about 3.4 liters: one-third of its rated capacity
preloadp₀ = 90 barnitrogen only: 10 Lminimum pressurep₁ = 100 barnitrogen 9.01 L · oil 0.99 LMaximum pressurep₂ = 160 barnitrogen 5.65 L · oil 4.35 LΔV3.36 L
Figure 43.16 · The accumulator from Example 43.16 in its three states, to scale: the useful oil is the difference between the gas volumes at minimum and maximum pressure.
⚠️
A pressure accumulator remains pressurized even when the machine is turned off. Before opening a circuit with a pressure accumulator, you must relieve the pressure using its valve and check the pressure gauge to ensure the pressure is at zero. The accumulator must be pre-charged only with nitrogen: never use air or oxygen, as they can explode when combined with pressurized oil. It is a pressure vessel that must undergo periodic inspections.

43.13 Basic Circuits

All circuits are built using the components we've covered so far. We'll look at six of them, ranging from the simplest to those found in cars. In the schematics, the control unit is always the one shown in Figure 43.6.

Control of a cylinder with a 4/3-way valve with a closed center

ABPTMY1Y2cylinder4/3-way directional valveclosed-centercontrol unit(pump, pressure relief valve,pressure gauge, filter)
Figure 43.17 · The simplest circuit: control unit, 4/3-way valve with closed center, double-acting cylinder.

When Y1 is energized, the left-hand box is moved to the center: P goes to A, the cylinder extends, and the oil on the rod side returns from B to T. When Y2 is energized, the right-hand box is moved to the center: P goes to B, and the cylinder retracts. When neither solenoid is energized, the springs return the valve to the closed center position: the cylinder stops where it is, and the pump—not knowing where to send the oil—raises the pressure to the relief valve’s set point and discharges everything there. This is fine for cycles in which the cylinder remains stationary for only a short time; otherwise, the oil heats up (example 43.13), and a variable-displacement pump or a tandem unit is recommended.

Speed Control

To adjust the speed, a unidirectional regulator is installed between the directional control valve and the cylinder, in the position selected in accordance with paragraph 43.11. On machine tools, two outlet regulators are usually installed—one on line A and one on line B—with check valves that allow oil to flow freely: this allows the outlet and return speeds to be adjusted separately, and the cylinder is always braked by the outgoing oil.

Shut-off using pilot-operated check valves

ABPTMY1Y2double check valvepiloted (hydraulic)4/3-way directional control valvewith floating center
Figure 43.18 · The hydraulic block: each of the two pilot-operated check valves opens only when there is pressure in the other line.

When the cylinder must remain stationary under load for an extended period, the closed-center configuration is not sufficient: the spool valve has a clearance of just a few micrometers and allows a small amount of oil to leak through, causing the cylinder to slowly give way. In this case, two pilot-operated check valves are installed as close to the cylinder as possible. When Y1 is energized, oil enters A, passing freely through the first valve; the pressure in line A pilots the second valve and opens the exhaust from B. The opposite occurs with Y2. In the rest position, both valves close with a perfect seal. The directional control valve must have a floating center: with A and B connected to T, the pilot lines are vented and the valves close immediately; with a closed center, pressure would remain trapped and the valves could remain slightly open.

Sequence with a sequence valve

1A Clamping2A MachiningABPTMY1Y2sequencesequence(60 bar)
Figure 43.19 · First, lock 1A closes; when its pressure reaches 60 bar, the sequence valve opens and working cylinder 2A starts moving.

When Y1 is energized, the oil flows to locking cylinder 1A, which has low resistance and closes first, while the sequence valve remains closed. When 1A comes into contact with the workpiece, the pressure rises; at 60 bar, the sequence valve opens and the oil flows to the working cylinder 2A. The clamping cylinder remains locked at a minimum of 60 bar throughout the entire machining process. When Y2 is activated, the two cylinders retract together: the oil exiting 2A flows freely back through the check valve in parallel with the sequence valve. The sequence pressure setting must be above the pressure required to move 1A under no-load conditions and below the pressure of the pressure-limiting valve, with a margin of at least 10 or 20 bar on either side.

The circuit of a press

workpiecesledABPTMY1Y2cylinder Ø160/100downward travelcounterbalancecounterbalance4/3-way center-position tandem directional control valve:In the neutral position, the pump dischargeswith almost no pressure
Figure 43.20 · A press: the tandem center directional control valve allows the pump to depressurize when at rest; the counterbalance valve prevents the ram from falling under its own weight.

The press cylinder operates vertically, with the piston rod at the bottom and the slide attached to the piston rod. Three features distinguish it from a typical circuit:

  • The distributor has a tandem system: between strokes, the pump sends oil directly to the reservoir with almost no pressure, and the oil does not heat up;
  • On the rod side of the line is the counterbalance valve, set slightly above the pressure created by the weight of the slide beneath the piston: the slide remains raised even when the distributor is open and descends only when oil pushes from above; A parallel check valve allows oil to flow freely upward;
  • The limiter sets the maximum force of the press; often, a pressure switch or a proportional valve stops the downward stroke at the desired force.
Example 43.17 · Force, Speed, and Counterbalance of a Press

A press has a cylinder with a diameter of 160 and a rod with a diameter of 100, a pressure relief valve set to 200 bar, and a pump with a flow rate of 40 L/min. The slide, including the rod and piston, has a mass of 1000 kg. Calculate the maximum force, the descent speed, the pressure created by the weight beneath the piston, and the hydraulic power at maximum pressure.

A1 = 3.1416 × 160² / 4 = 20,106 mm²; stem 3.1416 × 100² / 4 = 7,854 mm²; A2 = 20,106 − 7,854 = 12,252 mm²
maximum force: F = 20 × 20 × 10⁶ = 402,124 N ≈ 402 kN (approximately 41 metric tons)
descent speed: v = (40,000,000 / 60) / 20,106 = 666,667 / 20,106 = 33.2 mm/s
weight of the sled: 1000 × 9.81 = 9810 N → pressure under the piston p = 9810 / 12,252 = 0.80 N/mm² = 8.0 bar
Calibrated counterbalance with a 25% margin: 8.0 × 1.25 = 10 bar
Power at maximum pressure: P = 200 · 40 / 600 = 13.3 kW
402 kN, 33 mm/s, counterbalance at approximately 10 bar, 13.3 kW when the press is operating at full force

The Hydraulic Clamping of the Lathe Spindle

spindledrive head and tie rodrotating cylindercouplingrotatingABY1Y2distributor4/2 with twosolenoidsMreduceradjustablepressure gaugepressure switch(subject to CNC approval)
Figure 43.21 · The rotating cylinder, located behind the drive head, pulls or pushes the link that opens and closes the jaws. The pressure reducer regulates the pressure—and thus the clamping force.

On CNC lathes, the self-centering chuck is not tightened with a wrench: behind the drive head is a rotating cylinder that turns along with the spindle and, via a hollow tie rod that passes through the spindle, moves a wedge mechanism that shifts the jaws. Oil is supplied to the cylinder via the rotary joint, which connects the stationary pipes to the rotating part. The circuit consists of:

  • an adjustable pressure reducer with its own pressure gauge: the clamping pressure is selected based on the workpiece—high for a solid bar, low for a thin-walled tube that would otherwise deform;
  • a 4/2-way valve with two solenoids, often equipped with a mechanical lock, which remains in its last position even when the power is off: a spindle must never open on its own;
  • a pressure switch that gives the go-ahead to the CNC: if the pressure drops, the spindle does not start or stops;
  • Inside the rotating cylinder, there are check valves that maintain the clamping force for a short time even after the pressure drops.

Clamping and unclamping are controlled by M-codes selected by the machine manufacturer, or by a foot pedal when the spindle is at a standstill. The clamping force when the spindle is stationary is proportional to the pressure; however, as the spindle rotates, the centrifugal force of the jaws reduces this force, with the reduction increasing proportionally to the square of the rotational speed (Chapter 9, Section 9.7). For this reason, the pressure is selected based on the operating speed.

Example 43.18 · What pressure should be applied to the spindle?

The rotating cylinder of a lathe has a piston with a diameter of 130 and a through-hole with a diameter of 52; the spindle mechanism multiplies the force of the tie rod by 2.0 (approximate value: the actual value is in the spindle manual). The jaws are those from Example 9.10: at 3,500 rpm, the centrifugal force of the three jaws is 38.7 kN. At least 20 kN of clamping force is required during cutting. What pressure should be set on the pressure reducer? What force is generated at 8 bar when machining a thin workpiece at low speeds?

Effective area: A = 3.1416 · (130² − 52²) / 4 = 3.1416 · (16,900 − 2,704) / 4 = 11,150 mm²
clamping force at rest per bar: 0.1 N/mm² · 11,150 mm² · 2.0 = 2,230 N = 2.23 kN per bar
Required static force: 20 + 38.7 = 58.7 kN → p = 58.7 / 2.23 = 26.3 bar → set to 27 bar
Verification: at 27 bar when stationary, 27 × 2.23 = 60.2 kN; at 3,500 rpm, 60.2 − 38.7 = 21.5 kN, which is ≥ 20 kN ✓
at 8 bar: 8 × 2.23 = 17.8 kN at a standstill, sufficient only at low RPMs
Pressure reducer set to 27 bar for operation at 3,500 rpm; at 8 bar, the thin workpiece is clamped with 17.8 kN, but the speed must be kept low
🖥️
The spindle speed limit is set in the program. When the spindle is operating at low pressure, the manufacturer’s spindle speed limit is no longer sufficient: it must be reduced in the program using G50 S... before machining in G96 (Siemens LIMS), as discussed in Chapters 9 and 26.

43.14 Safety, Maintenance, and Malfunctions

Safety

A hydraulic system stores a great deal of energy in a small space, and accidents involving it can be serious. There are few rules, and they are not up for debate:

  • Before performing any work, relieve the pressure: shut down and isolate the motor, discharge the accumulators, and ensure the pressure gauge reads zero. Suspended loads (slides, arms, presses) must be supported or mechanically locked in place: a stationary cylinder does not provide support.
  • Never try to locate a leak with your hands. A thin stream of oil at 200 bar pierces the skin like a needle and injects oil into the tissues; the wound looks like a tiny hole, but it’s a surgical emergency: go immediately to the emergency room and explain that it’s a high-pressure oil injection. Use a workpiece of cardboard to check for leaks.
  • Hoses age over time. They are marked with the maximum pressure and the date of manufacture; they should be replaced when they are cracked, crushed, swollen, or show signs of wear near the fillets, and in any case after the period specified by the manufacturer (usually a few years). They must not be twisted or bent below the minimum bend radius. Where they are near people, they must be protected with sleeves or guards, and long hoses must be secured with clamps to prevent them from whipping around in the event of a rupture.
  • Hot oil burns, and atomized oil burns even more intensely: a spray from a broken fillet onto a hot surface can catch fire. Where this risk exists, fire-resistant fluids are used.
  • Oil on the ground is slippery and pollutes: clean it up immediately with an absorbent pad, and take the used oil to an authorized collection point—never pour it down the drain.

Maintenance

  • Every day: oil level, temperature, visible leaks, unusual noises;
  • Periodically: check the return filter clogging indicator (replace the cartridge; do not clean it), check the air filter on the cap, clean the heat exchanger, and tighten the fillets;
  • Oil analysis once or twice a year, or based on operating hours: viscosity, water content, cleanliness class; the oil is changed when the analysis indicates it is necessary, or according to the owner's manual;
  • When changing the oil, clean the reservoir and refill it only with filtered oil of the same grade and type: mixing different types of oil can cause them to react with each other.

Common Malfunctions

Cavitation is the most common type of failure. If the suction line is blocked, the pipe is too small, the oil is too cold and thick, or the pump is running too fast, the pressure at the pump inlet drops so low that the oil begins to boil even at room temperature: steam bubbles form, which implode violently once they reach the high-pressure zone. You hear a gravel-like noise in the pump, and the implosions erode the metal like sandblasting. Air in the oil produces similar symptoms; it enters through a loose suction fillet or a return line that slams above the oil level: it causes foaming and makes the movements sluggish and jerky.

SymptomPossible causesWhat to Do
Noisy pump (gravel), jerky movementscavitation: clogged suction filter, cold oil, narrow suction line; or air being drawn inClean or replace the filter, heat the oil before starting work, and check the suction fillets and the oil level
Oil that's too hotA pressure relief valve that always releases (closed-center with a fixed pump), a dirty heat exchanger, low fluid level, internal leaks, oil with the wrong viscosityCheck the circuit or the distributor, clean the heat exchanger, top off the fluid, and check for internal leaks
The pressure isn't risingLow-pressure relief valve set too low or stuck open due to dirt; worn pump; directional control valve or cylinder leaking toward TCheck the calibration, disassemble and clean the flow limiter, and measure the pump's flow rate
The cylinder drops or gives way on its ownWorn piston rings, leaking directional control valve spoolReplace the gaskets; install pilot-operated check valves or a counterbalance mechanism
Slow MovementsWorn pump (low volumetric efficiency), closed regulator, oil that is too hot and thinmeasure the flow rate, check the calibrations and the temperature
External Leaksloose fillets, damaged stem seals, scratched stem, damaged hoseTighten to the correct torque, replace the gaskets or hose; a scratched stem can be rechromed
Milky or foamy oilwater in oil (condensate, perforated water-oil heat exchanger) or airoil analysis, oil change, checking for water or air ingress

43.15 The Formulas in This Chapter

What Are You Looking For?FormulaUnits
Pressure and Forcep = F / A · F = p · AN/mm² (1 N/mm² = 10 bar), N, mm²
Hydraulic pressF2 = F1 · A2 / A1 · s2 = s1 · A1 / A2N, mm
Flow RateQ = A · v · Q = 6 · A · vm³/s · L/min, where A is in cm² and v is in m/s
ContinuityA1 · v1 = A2 · v2
Speed in a Tubev = 21,22 · Q / d²m/s, where Q is in L/min and d is in mm
Diameter of a piped = √(21,22 · Q / v)mm
Hydraulic powerP = p · Q / 600kW, with p in bar and Q in L/min
Reynolds numberRe = v · d / ν (laminar flow below 2300)pure number
Pump Flow RateQ = V · n · ηv / 1000L/min with V in cm³
Electric motor powerPm = p · Q / (600 · ηt) · ηt = ηv · ηhmkW
Areas of the cylinderA1 = π · D² / 4 · A2 = π · (D² − d²) / 4mm²
Cylinder: ForcesF1 = p · A1 · ηm · F2 = p · A2 · ηmN
Cylinder: speedv1 = Q / A1 · v2 = Q / A2mm/s with Q in mm³/s
Regenerative connectionF = p · As · v = Q / AsN, mm/s
Hydraulic motor: torqueM = V · Δp · ηhm / (20π)N·m with V in cm³ and Δp in bar
Hydraulic motor: RPMn = 1000 · Q · ηv / Vrevolutions per minute
Heating in the valvesabout 0.6 °C for every 10 bar drop°C
Boyle's Lawp0 · V0 = p1 · V1 = p2 · V2 (absolute pressures)bar, L
Useful volume of the storage tankΔV = V1 − V2L

43.16 Exercises

Try to solve them on your own, using a calculator, before looking at the solution.

Exercise 1. In a hydraulic press, the small piston has a diameter of 25 mm and the large piston has a diameter of 160 mm. If the small piston is pushed with a force of 300 N, what is the pressure in the oil, and what force does the large piston exert?
Solution

A1 = 490.9 mm²; p = 300 / 490.9 = 0.611 N/mm² = 6.1 bar. The areas are in the ratio (160 / 25)² = 40.96, so F2 = 300 · 40.96 = 12,288 N.

Exercise 2. What pressure is required for a cylinder with a diameter of 100 to exert a force of 100 kN?
Solution

A = 3.1416 × 100² / 4 = 7,854 mm²; p = 100,000 / 7,854 = 12.73 N/mm² = 127.3 bar.

Exercise 3. A cylinder with a diameter of 50 must be discharged at 0.2 m/s. What flow rate is required?
Solution

A = 3.1416 × 5² / 4 = 19.63 cm²; Q = 6 × 19.63 × 0.2 = 23.56 L/min.

Exercise 4. 15 L/min flow passes through a pipe with an inner diameter of 10 mm. What is the oil’s velocity? Is this suitable for a discharge line at 150 bar? What about a suction line?
Solution

v = 21.22 × 15 / 10² = 3.18 m/s. For a discharge pressure of 150 bar (4 to 5 m/s), this is acceptable—in fact, there is some margin; for a suction pressure (0.5 to 1.2 m/s), it is too high: the pump would cavitate.

Exercise 5. A pump delivers 12 L/min at 250 bar. What is the hydraulic power? What kind of electric motor is needed with a total efficiency of 0.80?
Solution

P = 250 × 12 / 600 = 5 kW; Pm = 5 / 0.80 = 6.25 kW, so a 7.5 kW motor.

Exercise 6. A gear pump with a displacement of 25 cm³/revolution runs at 1,450 rpm with ηv = 0.90. What is its flow rate?
Solution

Q = 25 × 1,450 × 0.90 / 1,000 = 32.63 L/min (theoretical value: 36.25 L/min).

Exercise 7. What is the minimum inside diameter of the suction pipe for a 40 L/min pump, given that the oil velocity must not exceed 0.8 m/s?
Solution

d = √(21.22 × 40 / 0.8) = √1061 = 32.6 mm: Choose the first commercial diameter above this value, for example, 40 mm.

Exercise 8. A cylinder with a diameter of 80 and a rod diameter of 45 operates at 160 bar with a flow rate of 30 L/min. Calculate the forces and velocities during the extension and retraction strokes.
Solution

A1 = 5,026.5 mm²; stem 1,590.4 mm²; A2 = 3,436.1 mm². F1 = 16 × 5,026.5 = 80,425 N; F2 = 16 × 3,436.1 = 54,978 N. Q = 500,000 mm³/s; v1 = 500,000 / 5,026.5 = 99.5 mm/s; v2 = 500,000 / 3,436.1 = 145.5 mm/s.

Exercise 9. The same cylinder from Exercise 8 is connected in a regenerative configuration. What are its output force and velocity?
Solution

F = 16 × 1590.4 = 25,447 N; v = 500,000 / 1590.4 = 314.4 mm/s (almost 19 m/min, more than three times the normal thrust).

Exercise 10. A 50 cm³/rev hydraulic motor receives 30 L/min at Δp = 120 bar. Calculate the theoretical torque, rotational speed, and power.
Solution

M = 50 · 120 / 62.83 = 95.5 N·m; n = 1000 · 30 / 50 = 600 rpm; P = 120 × 30 / 600 = 6 kW (check: 95.5 × 2 × 3.1416 × 600 / 60 = 6000 W).

Exercise 11. A winch requires 400 N·m, and the system can supply the motor with a pressure difference of 200 bar. What is the minimum displacement the motor must have (ignoring efficiency)?
Solution

V = M · 20π / Δp = 400 · 62.83 / 200 = 125.7 cm³/revolution: Choose the first engine in the catalog that is equal to or larger than this value.

Exercise 12. A 4-liter accumulator is precharged to 60 bar and operates between 70 and 120 bar (gauge readings). How much oil does it return?
Solution

Absolute pressures of 61, 71, and 121 bar. V1 = 61 × 4 / 71 = 3.44 L; V2 = 61 × 4 / 121 = 2.02 L; ΔV = 3.44 − 2.02 = 1.42 L.

Exercise 13. A fixed pump with a flow rate of 25 L/min discharges its entire flow through a pressure relief valve set at 140 bar. How much power is converted into heat? By how much does the oil heat up with each pass, according to the rule of thumb?
Solution

P = 140 × 25 / 600 = 5.83 kW; ΔT ≈ 140 / 10 × 0.6 = 8.4 °C per pass.

Exercise 14. Using the spindle chuck from Example 43.18 (2.23 kN per bar), what is the clamping force at rest at 12 bar? Is it sufficient at 3,500 rpm with the same jaws?
Solution

12 · 2.23 = 26.8 kN at rest. At 3,500 rpm, the centrifugal force of the jaws is 38.7 kN, which is greater than the clamping force: the workpiece would no longer be held in place. At 12 bar, the machine must be operated at a much lower speed.