Chapter 35

Threading Dimensions

A thread may have the correct outside diameter but still fail to screw in. What determines a proper fit is the mean diameter, along with the pitch and the flank angle—dimensions that cannot be measured with a slip gauge. In this chapter, we’ll look at all the tools used to measure these parameters—from thread counters to go/no-go gauges, from micrometers with tips to the three-wire method, all the way to profile projectors and thread inspection directly on a CNC lathe—with examples using actual screws.

35.1 What is measured in a thread?

A thread is a profile that repeats itself along a helix (Chapter 17). To determine whether it is correct, a single number is not enough: you need to know several measurements, and each requires its own tools. Before picking up a caliper, it’s best to know what you’re looking for and how important it is.

d · outer diameterd₂ · average diameterd₁ · corePP/2P/2α = 60°crestflankbottomAxial cross-section of the screw, upper half (base profile)
Figure 35.1 · The dimensions of a metric thread. On the mean diameter d₂, the thread groove and the tooth are each half a pitch wide: this is where the flanks of the screw and the nut rest.
MagnitudeWhat does it decide?What is it measured with?
Outer diameter d (screw) or shank diameter D₁ (nut)make sure the ridges do not touch the bottom of the other workpiece; the strength of the ridgemicrometer or caliper on the ridges; smooth P/NP pad for D₁
Average diameter d₂ or D₂The clearance between the flanks: this is the primary dimension of the fitthree files, dial micrometer, thread gauges, balls
Core diameter d₃ of the screwthe screw's resistance and the clearance at the bottomfine-tip micrometer, projector
Step Pthat all the teeth fall into the compartments, even those far from the beginningthread gauge, multi-step gauge, projector, microscope
Angle α and Profile Shapethat the sides match up along their entire heightthread gauge (visible), template projector, microscope
Taper (R and NPT gas threads)the seal and the final position of the filletTapered calipers with a scale, measuring the diameter at two points

Of all these, the one that really matters is the average diameter, because the screw and nut come into contact along their flanks, not at their peaks. The outside diameter of a screw, on the other hand, has a wide tolerance and serves only to provide clearance at the bottom: a screw can measure 9.80 mm at the crests and still be perfectly acceptable, as we’ll see in Example 35.3. Anyone who checks a thread using a caliper only on the crests has, in practice, not checked it at all.

Simple Mean Diameter and Virtual Mean Diameter

The average diameter measured at a single point along the files is called the simple average diameter d₂s: it indicates how wide the file groove is at that position. But if the pitch is not exact, the teeth farther from the start no longer fall in the center of the nut’s slots and end up pressing against the side: to screw in, the bolt behaves as if it were larger. The same thing happens with an angular error. The diameter of a perfect lead screw—as long as the thread length—that mates exactly with the actual screw, including all its errors, is called the virtual mean diameter d₂v. This is what determines whether the screw will fit.

The gauge profile passes (without errors)interferenceΔPscrew with pitch error (exaggerated)ΔP/2fP/2α/2fP = ΔP · cot(α/2)
Figure 35.2 · On the left, a screw with a pitch slightly longer than it should be: the threads shift further and further, and the right flank enters the gauge’s profile (shown in red). On the right, the reasoning behind the formula: moving the flank by ΔP/2 along the axis is equivalent to moving it by fP/2 in the radial direction.
Virtual Average Diameter (Overview)
d2v = d2s + fP + fα fP = |ΔP | · cot α2 = 1.732 · |ΔP | (for 60°)
d2v virtual mean diameter · d2s simple mean diameter, measured using the files · fP increase due to pitch error · ΔP accumulated pitch error over the screw-in length · fα increase due to half-angle errors (ISO 1502 calculates this using factors that depend on the sign of the error; we merely mention it here) · α profile angle · all in mm. For a lead screw, the signs are reversed: the errors make it appear smaller.

This gives rise to the rule for gauges, known as Taylor’s principle: a gauge that passes must check everything as a whole and over the entire length (i.e., the virtual diameter, at the maximum material limit), while a gauge that fails must check only a single dimension (the simple average diameter, at the minimum material limit). We will discuss this in Section 35.4.

Example 35.1 · An M12 screw with a slight pitch error

An M12-6g screw, with its three threads, has a diameter d₂s = 10.700 mm. The projector shows a cumulative pitch error of 0.015 mm over the screw-in length. The angular errors are negligible. The 6g limits for the mean diameter are 10.679 and 10.829 mm (table in Section 35.8).

fP = 1.732 × 0.015 = 0.026 mm
d2v = 10.700 + 0.026 = 10.726 mm
d₂s = 10.700 ≥ 10.679 (if it doesn't pass, it doesn't go in) · d₂v = 10.726 ≤ 10.829 (if it passes, it goes in)
The screw is in good condition: both checks have been passed
Example 35.2 · It fits well on the wires, but the connector won't go in

An M10-6g screw (d₂ between 8.862 and 8.994 mm) measures d₂s = 8.980 mm on the files, which is within the limits. However, the pitch has a cumulative error of 0.010 mm.

fP = 1.732 × 0.010 = 0.017 mm
d2v = 8.980 + 0.017 = 8.997 mm > 8.994 mm
The ring fits but does not screw in, even though the measured average diameter is within tolerance: the defect is in the pitch.

This is a classic example of someone saying, “I measured it with a feeler gauge and it’s good, but the nut won’t go on.” On a CNC lathe, pitch errors are rare; they are more likely to occur with rolled threads, on long workpieces that heat up during machining, and on screws made with worn-out machines.

35.2 Identifying a Thread: Thread Gauge and Thread Counter

Before measuring a thread accurately, you need to know what kind of thread it is. You can identify it in a matter of seconds using two simple tools (the complete procedure is described in section 17.14).

  • The vernier caliper is used to measure the diameter. On the screw, the outside diameter is measured at the peaks: a metric screw always measures slightly less than the nominal value (for M10-6g, between 9.732 and 9.968 mm). Measure the core diameter D₁ in the hole and add approximately one pitch. If the diameter changes from one end to the other by about 1 mm every 16 mm, the thread is tapered.
  • The thread gauge (also called a thread comb or pitch gauge). It consists of a set of comb-shaped steel strips, each with a thread profile and the pitch stamped on it. There is usually a metric set at 60° (pitch ranging from about 0.25 to 6 mm) and an inch-thread set, at 55° for Whitworth and gas threads or at 60° for standard threads (from about 4 to 60 threads per inch). Some models have both sets at opposite ends of the same case.
1.5 · 60° bladecorrect pitch: no gapM10 screw (P = 1.5 mm)slat 1.6 · 60°Incorrect pitch: light passes throughM10 screw (P = 1.5 mm)gap
Figure 35.3 · The thread gauge resting on an M10 screw and viewed against the light. On the left, the 1.5-thick blade fits into all the slots without any gaps. On the right, the 1.6-thick blade rests only on a few teeth, and light (shown in blue) passes through the gaps between the others, becoming increasingly visible toward the ends.

How to use the thread counter:

  • Clean the thread of chips and oil, which fill the crevices and are misleading;
  • Place the blade with its edge parallel to the screw's axis, in a plane that passes through the axis (when inserting it into a hole, start with the narrower end of the blade and hold it straight);
  • Hold it up to the light: the correct blade fits into all the slots, covering at least six or eight teeth, without letting any light pass;
  • If the light shifts more and more toward one end, the pitch is close but incorrect; if it passes equally on either side of each tooth, the pitch is correct but the angle is different (55° instead of 60°, or vice versa).
⚠️
The thread gauge identifies, but does not measure. It distinguishes between a 1.5 pitch and a 1.75 pitch, but it does not detect an error of a few hundredths and says nothing about the average diameter. Between pitches that are very close (1.5 mm and 16 threads per inch, i.e., 1.588 mm; 2 mm and 13 threads per inch, i.e., 1.954 mm), the difference is visible only on a long gauge with many teeth. To be certain, the pitch is measured over ten threads, as described in the following paragraph.
Example 35.3 · A screw to be identified and evaluated based on its ridges

A screw measures 9.82 mm at the peaks; the metric tap from 1.5 to 60° fits without clearance on eight teeth. What kind of screw is this, and is its outer diameter correct?

60° and 1.5 pitch with a diameter close to 10 mm → M10 coarse thread
Outer diameter limits for the M10-6g (example: 17.9): 9.732 to 9.968 mm
9.732 ≤ 9.82 ≤ 9.968 → outer diameter within tolerance
It's an M10—it works well on ridges. To find out if it's really good, you need to check the average diameter.

35.3 Measuring Stride Length Over Ten Steps

When a thread counter isn't enough—or when there isn't one—the pitch is measured with a vernier caliper. It is never measured between two adjacent ridges, but between two ridges that are far apart: count eleven ridges, which make up ten pitches, read the distance between the first and the eleventh, and divide by ten. With a digital caliper, place the tips of the jaws on the ridges, or use a steel ruler with a magnifying glass; for a hole with threads, do the same on a plasticine impression or a cast.

1234567891011L = 10 · P11 crests = 10 passes: P = L / 10
Figure 35.4 · The tips of the caliper are on the first and eleventh crests: there are ten steps between them. The crests are counted; the steps are the spaces between one crest and the next.
Step measured over multiple steps
P = Lnn error per pitch = error on Lnn threads per inch z = 25.4P
P pitch in mm · Ln measured distance between the first and last peaks, in mm · n number of pitches (there are n + 1 peaks) · z threads per inch.

There are two reasons for the ten steps. The first: the reading error (the gauge, the point where the tip rests, the eye) is always the same—a few hundredths—but when divided by ten, it becomes a few thousandths per step. Second: a slightly incorrect step adds up, and over ten steps, an imperceptible difference becomes nearly a millimeter.

Example 35.4 · 1.5 mm pitch or 16 threads per inch?

A screw with a diameter of approximately 9.5 mm has a pitch that appears to be 1.5 mm. It could be a 3/8-16 UNC (P = 25.4 / 16). Between the first and eleventh threads, the caliper reads 15.02 mm.

16 threads per inch: P = 25.4 / 16 = 1.5875 mm → 15.875 mm over 10 threads
1.5 mm increment → 15,000 mm over 10 increments
Difference over one step: 0.0875 mm (hard to see); over ten steps: 0.875 mm (impossible not to see)
measurement: P = 15.02 / 10 = 1.502 mm
The pitch is 1.5 mm: the screw is metric. With an error of 0.02 mm, the pitch is known to within 0.002 mm.

35.4 Threaded go/no-go gauges

On the production line, no one measures every thread with a string; instead, they use threaded gauges (ISO 1502 standard), which do not provide a numerical value but rather a pass/fail result. For lead screws (threaded holes), the swab, for the screws, thering. Both have a "pass" side (P, or "GO") and a "no pass" side (NP, or "NO GO"), usually indicated by a red collar or band.

M10 6HP · passesNP · does not fitmany threads, full profilefew threads, truncated profilenutgaugenutgauged₂P: rests on the entire sideNP: rests only near d₂
Figure 35.5 · Above, a double M10 6H plug: on the left, the “passes” plug, which is long and has a full profile; on the right, the “does not pass” plug, which is short, has a few truncated threads, and features a red band. Below, the contact with the nut: the “pass” screw rests along its entire flank, while the “non-pass” screw rests only in a band near the mean diameter.
  • The nut (P) has a full profile and is approximately as long as the screw-in length. It is machined to the maximum material limit of the workpiece (the largest permissible mean diameter for the screw, the smallest for the nut) and checks the entire assembly: the virtual mean diameter—that is, including pitch and angular errors—and ensures that the peaks and valleys do not interfere. It must screw in by hand, without forcing it, along the entire length of the thread.
  • The non-passing (NP) thread is machined to the minimum material limit and has only two or three threads, with truncated crests and a relieved bottom. Thus, it contacts only the flanks, in a band near the mean diameter, and detects neither pitch errors (which do not accumulate with few threads) nor errors in the outer and core diameters. It checks only one dimension: the simple mean diameter. It can be screwed in for a maximum of two turns; if it goes in further, the thread is too wide (nut) or too narrow (screw).

If the "non-pass" were as long and complete as the "pass," a screw that is too thin but has a pitch error would get stuck in the "non-pass" because of the pitch and would be judged to be good: that is precisely what the truncated, short profile prevents.

P ring: Screw it on by hand along its entire lengthNP ring: maximum 2 turnsM10-6g screw (ring cross-sections shown in light blue)
Figure 35.6 · The rings on an M10-6g screw. The ring that slides on (left) has reached the middle of the screw by turning it by hand; the ring that does not slide on (right, with the red band) stopped at the start of the thread after fewer than two turns. The screw is in good condition.
SkipIt doesn't go throughReviewWhat does that mean?
It all fitsIt doesn't fit, or at most 2 turnsgoodvirtual and simple average diameter within the limits
It won't open, or it freezes updoesn't fitto be resumedscrew too large or nut too tight, or a pitch error, burrs, or chips in the thread
It all fitsenters more than 2 turnsdiscardThe screw is too thin or the nut is too large: the material that has been removed cannot be restored
doesn't fitentercheck everythingSeverely deformed thread (oval, conical) or mixed thread sizes: measured using threads
Example 35.5 · What Do the Gauges Show for the Three Screws?

Check the three M10-6g screws with the P and NP washers.

Screw A: The "pass" screw goes all the way in by hand; the "non-pass" screw stops after one turn → good
Screw B: If the screw fits, it seats on the third thread; if it doesn't fit, it won't go in → it's too large for the virtual average diameter (or has a burr): clean it and try again, then measure it with the threads to determine whether the issue is the diameter or the pitch
C-thread: the pass fits, the non-pass fits for four turns → average diameter less than 8.862 mm
A: Good, B: To be revisited once the cause is identified, C: Reject
🔧
How to Use Thread Gauges. Clean the threads and the gauge before testing; a drop of light oil helps. Turn the gauge with two fingers: if you need a wrench, the result is already “does not pass.” For a through hole, test from both sides. The gauge wears out with use, and once worn, it will accept workpieces that are too large; for this reason, gauges have a wear limit and must be inspected periodically like all tools (Chapter 31). In addition to threaded gauges, smooth gauges are also needed: the smooth P/NP plug gauge for the D₁ shank of the nut and the smooth fork gauge (or micrometer) for the outer diameter of the screw.

35.5 Adjustable rings, feeler gauges, and roller forks

It is not easy to measure the inside diameter of a threaded ring. For this reason, go rings are almost always adjustable: they have a radial slot and one or more screws that open or close them by a few hundredths. They are adjusted against a setting plug—a precision threaded plug calibrated in the metrology lab. The setting plug usually has one section with the full profile, against which the ring is adjusted along its sides, and another section with truncated ridges, which allows one to verify that the ring has been adjusted along its sides and not at the bottom. Once the ring is adjusted, the screws are locked in place and sealed with a drop of varnish: if the seal is broken, the ring must be rechecked.

M10adjustment and locking screwsslotadjustable P-ringcomplete profiletruncated profilestop block
Figure 35.7 · On the left, a front view of an adjustable ring: the slot and screws allow its diameter to be adjusted. On the right, the stop block used for adjustment: the full-profile section is for the sides, and the truncated-profile section is for adjustment.

When inspecting hundreds of screws a day, turning a ring is too slow. Instead, a roller fork gauge is used: a C-shaped frame with two pairs of threaded rollers (or with annular grooves spaced at regular intervals), one pair that the screw passes through at the entrance and one pair that the screw no longer passes through inside. The screw is pushed inside without being turned: it must pass over the “pass” rollers and stop on the “fail” rollers. The rollers rotate on the screw without scratching it. There are also roller gauges equipped with a dial indicator, which, in addition to indicating “pass” or “fail,” show how much the average diameter deviates from the set value—useful for monitoring the machine (Chapter 38).

screw(view along the axis)NP rollersP rollers
Figure 35.8 · Roller fork gauge viewed along the screw axis. The screw, pushed from below, has passed the “pass” rollers and is resting on the “fail” rollers: it is in good condition.

35.6 The thread micrometer

A thread micrometer is a standard micrometer with two special tips: on the anvil, a V-shaped insert that straddles a tooth; on the stem, a conical tip that enters the opposite groove. The tips contact the flanks near the mean diameter, and the micrometer reads d₂ directly, without any calculations. The tips are interchangeable, and each pair covers a specific pitch range (for example, from 0.4 to 0.5 mm, from 0.6 to 0.9, from 1 to 1.75, from 2 to 3, from 3.5 to 5): with the wrong pair, the contact point falls far from d₂, and the reading is invalid.

d₂V-shaped insertstraddling the toothconical tipin the slotreading = d₂
Figure 35.9 · The thread micrometer: the V-shaped insert grips a tooth, and the conical tip enters the groove from the opposite side (offset by half a pitch). The red dots indicate the contact points on the mean diameter d₂.

The rule for zeroing is simple: every time you change the tips, you must reset the zero. On a 0–25 mm micrometer, bring the tips into contact with each other (the cone enters the V-notch) and set the reading to zero. On larger micrometers (25 to 50 mm, 50 to 75 mm), use a reference bar with shaped ends, as long as the initial range: the reading must match the value marked on the gauge; if it does not, adjust the zero or account for the difference.

The thread micrometer is convenient and fast, but it contacts the threads at only two points, detects angular errors, and its tips wear out. With an indicative uncertainty of 0.01 mm, according to the rule of tenths (paragraph 31.8), it is suitable for average diameter tolerances of 0.1 mm and above: this applies to 6g threads from M10 and up, and is borderline for smaller ones. For more precise inspections, the three-wire gauge is used.

Example 35.6 · An M16 thread gauge

A M16-6g screw (P = 2 mm) is measured using the 2- to 3-mm tips. The micrometer, set to zero, reads 14.690 mm.

Nominal d₂: 16 − 0.649519 × 2 = 14.701 mm
6g: es = −38 µm, Td2 = 160 µm → d₂ max = 14.701 − 0.038 = 14.663 mm; d₂ min = 14.663 − 0.160 = 14.503 mm
14.690 > 14.663 by 0.027 mm
The screw is too big: the ring won't fit. Go over the last, deepest pass again.
Example 35.7 · Zeroing with the bar and reading on M30

A micrometer for threads ranging from 25 to 50 mm, when used on the 25-mm reference bar, reads 25.006 mm. When used on an M30-6g screw (P = 3.5 mm), it reads 27.640 mm. For the M30, the standard specifies es = −53 µm and Td2 = 212 µm.

zero error: 25.006 − 25.000 = +0.006 mm → each reading must be reduced by 0.006
Measured d₂: 27.640 − 0.006 = 27.634 mm
Nominal d₂: 30 − 0.649519 · 3.5 = 27.727 mm → max 27.727 − 0.053 = 27.674; min 27.674 − 0.212 = 27.462 mm
rule of tenths: 0.212 / 10 = 0.021 mm, greater than the micrometer's uncertainty (0.01) → suitable instrument
d₂ = 27.634 mm, within the limits of 27.462–27.674: screw is within the average diameter tolerance

35.7 The Three-File Method: Principle and Optimal File

The three-wire method, introduced as a calculation in Section 6.11, is the most accurate way to measure the average diameter in a workshop. Three hardened and ground steel wires, all of the same diameter df (in Chapter 6 we referred to it as dw), are placed in the threads: two on one side, in two adjacent grooves, and one on the opposite side, in the middle groove. Using a flat-face micrometer (or a dial indicator on a workbench), measure the dimension M above the wires. Each wire touches the two flanks of its groove, and its position depends solely on the width of the groove; for this reason, the average diameter can be determined from M.

dd₂dfOVα/2aba = df / (2 · sin α/2): from vertex V to center Ob = (P/4) · cot(α/2): from vertex V to d₂M/2 = d₂/2 − b + a + df/2
Figure 35.10 · A wire in the slot, magnified. The two extended sides meet at vertex V of the base triangle. The center O of the wire lies on the axis of the slot, at a distance a from the vertex; the mean diameter is at a distance b. The radii to the points of contact (in red) are perpendicular to the sides.

The figure shows the formula in three steps. The center of the wire lies on the bisector of the slot: the distance from the vertex is the radius of the wire divided by the sine of the half-angle, a = df / (2 · sin α/2). The mean diameter is located where the slot is half a pitch wide, that is, at b = (P/4) · cot(α/2) from the vertex. Half of the dimension M, measured from the screw axis to the top of the file, is then d₂/2 − b + a + df/2. Multiplying by two:

Three files: general formula for a symmetric profile with angle α
M = d2 + df · (1 + 1sin(α/2)) − P2 · cot α2
d2 = M − df · (1 + 1sin(α/2)) + P2 · cot α2
M: measured dimension above the wires · d2: average diameter · df: wire diameter (the actual value, as stated on the certificate) · P: pitch · α: profile angle · all in mm. The formula does not take the propeller’s pitch into account (paragraph 35.9).

The Optimal Thread

The formula applies to any thread that touches both flanks and protrudes from the ridges. But there is one diameter that is better than the others: the one that touches the flanks exactly at the mean diameter. This is the optimal thread (also called the best thread). With this thread, a small error in the thread angle has almost no effect on the measurement, because the point of contact remains fixed while the flank rotates around that point; and the contact occurs on the smoothest part of the flank, far from the crest and fillet transitions.

Optimal wire diameter
dott = P2 · cos(α/2)
metric and UN (60°): 0.57735 · P Whitworth and gas (55°): 0.56369 · P trapezoidal (30°): 0.51764 · P
d: optimal wire diameter in mm · P: pitch in mm · α: profile angle. For the metric system, the usable thread range is from approximately 0.505 · P (below this, the thread sinks in and does not protrude from the crests) to approximately 1.01 · P (above this, the contact falls on the edge of the crest).

For the 60° profile, you can check it by hand: the point of contact lies 0.75 · df above the vertex V, and the mean diameter lies at 0.433 · P; the two coincide if df = 0.433 / 0.75 · P = 0.577 · P. Files are sold in sets, with diameters close to the optimal values for the most common pitches; for a pitch that does not have its own file, use the one closest to the optimal value, provided it falls within the usable range, and calculate using its actual diameter.

d₂df = 0.505 · P (minimum)barely protrudes from the crestd₂df = 0.577 · P (optimal)touches the average diameterd₂df = 1.01 · P (maximum)touches the edge of the crest
Figure 35.11 · The same slot with three different files (red dots: the contacts). The minimum wire length barely reaches the height of the crest; the optimal length touches the mean diameter d₂; the maximum length touches the edge of the crest. Outside this range, measurement is not possible.
Example 35.8 · Which files for M10, G1/2, and Tr 24 × 5
M10 (P = 1,5; 60°): dOct = 0.57735 × 1.5 = 0.866 mm; usable range from 0.505 × 1.5 = 0.758 to 1.01 × 1.5 = 1.515 mm
G1/2 (14 threads per inch, P = 25.4 / 14 = 1.8143 mm; 55°): dOct = 0.56369 × 1.8143 = 1.023 mm
Tr 24 × 5 (P = 5; 30°): diameter = 0.51764 × 5 = 2.588 mm
Wire sizes: 0.866, 1.023, and 2.588 mm. For the M10, a 0.895 wire is also acceptable, as it falls within the acceptable range (example: 35.11)

35.8 The average diameter measured from the dimensions on the wires

By substituting the profile angle into the general formula, we obtain ready-made formulas for the most common threads. For metric threads, the two coefficients are whole numbers: 1 + 1/sin 30° = 3 and (1/2) · cot 30° = 0.866025.

Three Files: Ready-Made Formulas
ISO and UN metric (60°): d2 = M − 3 · df + 0.866025 · P
Whitworth and gas (55°): d2 = M − 3.165681 · df + 0.960491 · P
trapezoidal Tr (30°): d2 = M − 4.863703 · df + 1.866025 · P
with the optimal pitch, for the metric system only: M = d² + 0.866025 · P = d + 0.216506 · P
M: thread pitch · d2: average diameter · df: thread diameter · P: pitch · d: nominal diameter · all in mm. The last line reveals something interesting: with the optimal thread, on a properly sized metric screw, the threads measure slightly more than the nominal diameter (for M20 × 2.5: 20 + 0.541 = 20.541 mm).

The table provides, for coarse-pitch metric threads, the optimal thread size rounded to the nearest thousandth and the expected M dimensions: for the nominal d₂ and for the two limits of class 6g. The dimensions are calculated using the rounded thread value from the table; if your thread is different, recalculate using the formula. The deviations es and the tolerances Td2 are those specified in ISO 965-1, derived as described in paragraph 17.5.

ThreadP (mm)nominal d₂df wireM for nominal d₂6 g: d₂ max / minM max (6g)M min (6g)
M615,3500,5776,2155,324 / 5,2126,1896,077
M81,257,1880,7228,2727,160 / 7,0428,2448,126
M101,59,0260,86610,3258,994 / 8,86210,29310,161
M121,7510,8631,01012,37810,829 / 10,67912,34412,194
M14212,7011,15514,43412,663 / 12,50314,39614,236
M16214,7011,15516,43414,663 / 14,50316,39616,236
M182,516,3761,44318,54016,334 / 16,16418,49818,328
M202,518,3761,44320,54018,334 / 18,16420,49820,328
M222,520,3761,44322,54020,334 / 20,16422,49822,328
M24322,0511,73224,64922,003 / 21,80324,60124,401

Values in mm, recalculated by CNC Simulator Italia using d₂ = d − 0.649519 · P, df = 0.57735 · P (rounded), and M = d₂ + 3 · df − 0.866025 · P, without helix correction (1.5 to 2.5 µm for these threads). The standard takes precedence.

Example 35.9 · Complete inspection of an M20 × 2.5 screw

Check the M20-6g screw from Example 26.13, which has files measuring 1.443 mm. What dimensions would you expect, and what does a reading of 20.45 mm indicate?

optimal wire diameter: 2.5 / (2 · cos 30°) = 2.5 / 1.73205 = 1.4434 mm → 1.443 mm wire
Nominal d₂: 20 − 0.649519 × 2.5 = 18.376 mm
File constant: 3 · 1.443 − 0.866025 · 2.5 = 4.329 − 2.165 = 2.164 mm
Nominal M: 18.376 + 2.164 = 20.540 mm
6g: es = −42 µm, Td2 = 170 µm → d₂ max = 18.334 mm, d₂ min = 18.164 mm
M max = 18.334 + 2.164 = 20.498 mm · M min = 18.164 + 2.164 = 20.328 mm
Reading: 20.45 mm; d2 = 20.45 − 2.164 = 18.286 mm, within limits
Expected dimensions range from 20.328 to 20.498 mm; the screw measuring 20.45 has d₂ = 18.286 mm and is acceptable

The screw in Example 6.17, which measures 20.50 mm, has d₂ = 20.50 − 2.164 = 18.336 mm: it exceeds the 2 µm limit. With an uncertainty of a few micrometers, it falls into the gray area described in paragraph 31.9: the supplier cannot declare it acceptable, but a final light pass will bring it up to standard.

Example 35.10 · An M10 × 1.5 screw

0.866 mm files on an M10-6g screw. The measurement is 10.24 mm.

constant: 3 · 0.866 − 0.866025 · 1.5 = 2.598 − 1.299 = 1.299 mm
Nominal M: 9.026 + 1.299 = 10.325 mm · Max M = 8.994 + 1.299 = 10.293 mm · M min = 8.862 + 1.299 = 10.161 mm
d2 = 10.24 − 1.299 = 8.941 mm
d₂ = 8.941 mm, between 8.862 and 8.994: good, slightly above the center of the tolerance (8.928)
Example 35.11 · The same M10 with a thread that is not optimal

There's only one 0.895 mm set in the workshop. Can it be used on the M10? What is the marked value on a screw with a nominal d₂, and what is the d₂ of a screw marked 10.330 mm?

M10 usable range: 0.758 to 1.515 mm → 0.895 is acceptable
constant: 3 · 0.895 − 1.299 = 2.685 − 1.299 = 1.386 mm → nominal M = 9.026 + 1.386 = 10.412 mm
d2 = 10.330 − 1.386 = 8.944 mm
contact point: 0.75 × 0.895 = 0.671 mm above the vertex, compared to 0.433 × 1.5 = 0.650 mm for the average diameter
d₂ = 8.944 mm, good. The contact point lies 0.02 mm above d₂: an angular error in the thread would slightly affect the measurement
Example 35.12 · A G1/2 (55°) gas fillet

The G1/2 external thread has a diameter (d) of 20.955 mm and 14 threads per inch (paragraph 17.7). With 1.023 mm wires, M = 21.10 mm. According to ISO 228-1, the average diameter may be up to 0.142 mm below the nominal value in Class A and up to 0.284 mm below in Class B.

P = 25.4 / 14 = 1.8143 mm; h = 0.640327 · 1.8143 = 1.162 mm; nominal d2 = 20.955 − 1.162 = 19.793 mm
constant: 3.165681 · 1.023 − 0.960491 · 1.8143 = 3.238 − 1.743 = 1.496 mm → Nominal M = 19.793 + 1.496 = 21.289 mm
Measured d2 = 21.10 − 1.496 = 19.604 mm → 0.189 mm below the nominal value
Outside Class A (0.142), inside Class B (0.284): this is acceptable only if the drawing specifies G1/2 B
Example 35.13 · A Tr 24 × 5 adjustment screw

The drawing specifies d₂ between 21.150 and 21.400 mm (example values; for Class 7e, the limits are specified in ISO 2903). Wires measuring 2.588 mm; reading M = 24.55 mm.

Nominal d₂: 24 − 0.5 × 5 = 21.5 mm
constant: 4.863703 × 2.588 − 1.866025 × 5 = 12.587 − 9.330 = 3.257 mm
propeller correction (paragraph 35.9): tan ψ = 5 / (π · 21.5) = 0.07403 → ΔM = (2.588 / 2) · 0.07403² · cos 15° · cot 15° = 1.294 · 0.005480 · 3.6049 = 0.026 mm
d2 = 24.55 − 3.257 − 0.026 = 21.267 mm (without correction, it would be 21.293)
Dimensions, including correction: M max = 21.400 + 3.257 + 0.026 = 24.683 mm; M min = 21.150 + 3.257 + 0.026 = 24.433 mm
d₂ = 21.267 mm, within the limits. On the trapezoidal plate, the helix correction (26 µm) cannot be ignored

35.9 How to Take Measurements Using Strings

The formula is simple; the challenge lies entirely in threading the wires and reading the measurements carefully. Three thin wires that slip through your fingers as you tighten the micrometer are the classic test of a metrologist’s patience. Here’s how it’s done.

  • Wires from a single set. The three wires must come from the same set: they are identical to within a few tenths of a micrometer, and their actual diameter is specified on the certificate. A worn wire or one from a different set will result in an incorrect measurement (paragraph 35.14).
  • Wire holder. The wires are held in place by a support: small collets or clips attached to the micrometer, or a wire holder that allows them to hang in front of the faces. The wire must be free to align itself with the slot: if it is forced perpendicular to the screw axis, it will be off by tens of micrometers.
  • Micrometer on the stand. The micrometer is secured to its stand; the screw is held by hand or between the tips, and the faces must be flat and parallel: the faces of the micrometer must rest on the two wires on one side and on the other wire on the other side.
  • Apply a low, constant force. The wire should touch the side along a straight line: if too much force is applied, it will compress elastically and the measurement will decrease. Use a ratchet or a constant-force device. The recommended forces are a few newtons, lower for thin wires (roughly 1 to 3 N for wires less than one millimeter in diameter, up to about ten newtons for thicker ones); the exact values can be found in the standards and in the kit’s instructions.
  • More points. Measurements are taken at at least three points along the thread (start, middle, end) and in two directions at 90°: the differences indicate whether the thread is conical or oval.
  • Temperatures. The workpiece, wires, and micrometer must be at the same temperature (paragraph 31.10): a screw that has just been removed from the lathe is larger than it is at 20 °C.
Mtwo files aboveone stitch belowψview from abovethe wire follows the helix
Figure 35.12 · On the left, two files above, in two adjacent slots, and one below, offset by half a pitch: the faces of the micrometer measure M. On the right, viewed from above, the wire is not perpendicular to the axis but runs along the slot, inclined by the helix angle ψ (exaggerated in the drawing).

Correction for Propeller Pitch (Overview)

The three-thread formula envisions an annular cavity, closed in on itself like a groove. The actual cavity is a helix: the thread, which is straight, rests against the flanks at points that are no longer in the axial plane and stops slightly higher up. The M dimension becomes slightly larger, and the mean diameter calculated using the simple formula is slightly greater than the actual value. For 60° threads with a single start, the effect is one or two micrometers; for coarse pitches, trapezoidal threads, and multi-start threads, it becomes significant.

Propeller Pitch Correction for Three-Blade Propellers (Approximate Formula)
tan ψ = Phπ · d2 ΔM ≈ df2 · tan²ψ · cos α2 · cot α2
metric (60°): ΔM ≈ 0.75 · df · tan²ψ d2 = M − 3 · df + 0.866025 · P − ΔM
ψ: propeller angle relative to the mean diameter · Ph: propeller pitch (equal to P for a single-start thread) · d2: mean diameter · df: thread diameter · ΔM: the amount by which the M dimension increases for the propeller · all in mm. The value was also verified using a numerical calculation of the thread resting in the helical slot. For more precise cases, the standards provide complete formulas.
Example 35.14 · How much does the propeller weigh on M6, M20, and Tr 24 × 5?
M6 (P = 1, d₂ = 5.350, files 0.577): tan ψ = 1 / (π · 5.350) = 0.05950 (ψ = 3.4°) → ΔM = 0.75 · 0.577 · 0.003540 = 0.0015 mm
M20 (P = 2.5, d₂ = 18.376, files 1.443): tan ψ = 0.04331 (ψ = 2.5°) → ΔM = 0.75 · 1.443 · 0.001875 = 0.0020 mm
Tr 24 × 5 (example 35.13): ΔM = 0.026 mm
1.5 and 2 µm on metric threads, approximately 1% of the tolerance: these are disregarded. 26 µm on trapezoidal threads: these are corrected

35.10 Two-wire, core diameter and internal threads

The Two-File Method (Overview)

It can also be measured using just two wires, one on each side. However, the two opposite slots are offset by half a pitch, and the faces of the micrometer are angled; the dimension obtained is slightly different from that obtained with three wires and must be corrected using a formula that depends on the pitch and the diameter. For this reason, the three wires are used whenever possible. The two wires (or two balls) are used where there is no room for the third wire—on very short screws and in two-point instruments.

The core diameter

The d₃ diameter of the vine is measured using the dial micrometer (thin conical points or blades that reach the bottom of the cavity) or to the projector. On the lead screw, the D₁ core is the cylindrical portion of the threads: it is checked using a smooth plug gauge (pass or fail) or a bore gauge (Chapter 32), just like any other hole.

The average diameter of the internal threads

Threads cannot be held inside a hole. In production, the P/NP threaded gages described in paragraph 35.4 are used. For measurement, however, three-point internal micrometers with threaded heads (three sectors with a thread profile that widen until they touch the flanks) and internal thread comparators, with two jaws calibrated to a reference ring, are used. In the metrology lab, the ball method is used: two balls of optimal diameter, mounted on two arms, are inserted into the opposite bores, and the distance Mi between their innermost points is measured.

Micross-section of a nutballs in opposite compartmentscomparator
Figure 35.13 · The ball method on a lead screw in cross-section: two balls on two arms enter the opposite slots (staggered by half a pitch), and the dial indicator, zeroed against a reference mark, reads the Mi dimension between their innermost points.
Ball Method for Internal Threads (Overview)
D2 = Mi + ds · ( 1 + 1sin(α/2)) − P2 · cot α2 (metric): D2 = Mi + 3 · ds − 0.866025 · P
D2 average diameter of the lead screw · Mi distance between the innermost points of the two spheres · ds diameter of the spheres (the optimal value is the same as that of the files) · P pitch · α profile angle · all in mm. This is the “reversed” version of the file formula: the apex of the groove faces outward.
Example 35.15 · An M10 lead screw with balls

0.866-mm balls in an M10-6H lead screw; the dial indicator reads Mi = 7.73 mm. For the 6H, the average diameter ranges from 9.026 mm (the nominal value) to 9.206 mm.

D2 = 7.73 + 3 × 0.866 − 0.866025 × 1.5 = 7.73 + 2.598 − 1.299 = 9.029 mm
D₂ = 9.029 mm: just above the minimum of 9.026 mm; good, but close to the pass limit

35.11 The profile projector and the workshop microscope

The profile projector illuminates the workpiece from behind and projects its magnified shadow onto a frosted glass screen, 300 to 600 mm wide or more. The lenses provide magnifications of 10, 20, 50, or 100 times. The workpiece rests on a coordinate table that moves in micrometer increments; the screen rotates and has an angular scale with readings in minutes of a degree. On the thread, one can see the pitch, the angle, the crest and root radii, the burrs, and the shape of the profile.

60° profilelampcapacitorspacer between the tipslensscreen: magnified shadow
Figure 35.14 · Diagram of the projector: the light from the lamp, rectified by the capacitor, passes alongside the workpiece; the lens projects the magnified shadow of the outline onto the screen, against which the transparent template is placed at a 60° angle (in red) or the crosshairs are aligned.
  • Using templates. A transparent template with the thread profile drawn to scale (60°, 55°, trapezoidal)—often including the tolerance band—is placed on the screen. You check to see if the shadow falls within the tolerance band: this is a quick visual comparison check.
  • Angle measurement. Align the crosshairs with one side, read the angle, then do the same with the other side: this gives you the two half-angles, each relative to the perpendicular to the axis. A thread may have the correct total angle but different half-angles (a “crooked” profile), and this can only be detected in this way.
  • Measuring the pitch. Align one side with the crosshairs, then move the plate until the corresponding side ten steps further along aligns with the same line, and read the displacement: this is the measurement over ten steps described in paragraph 35.3, but taken with a micrometer.
  • Helix angle. Light passes through the chamber, which is tilted by the helix angle ψ: if the workpiece remains upright, one side casts a shadow on the other, and the profile appears blurred and distorted. Tilt the light head (or the workpiece, on the swivel tips) by an angle ψ, and the profile becomes sharp.

The workshop microscope (or measuring microscope) performs the same functions, but the user looks through the eyepiece instead of at a screen: magnifications ranging from 10x to 50x, an eyepiece with a reticle, and a goniometric head for measuring angles, as well as a coordinate stage with micrometer screws or optical scales. It is smaller and more precise than the projector when used on small workpieces; here, too, the workpiece is tilted by the helix angle.

Example 35.16 · Pitch and angle at the projector at 20x magnification

An M10 × 1.5 screw is mounted on the projector with the 20× objective lens. On the screen, ten steps measured using the scale total 300.6 mm. The semi-angles read are 30° 15′ and 29° 55′.

A 1.5 mm increment on the screen: 1.5 × 20 = 30 mm
ten actual steps: 300.6 / 20 = 15.03 mm → P = 1.503 mm (error of 0.003 mm per step, 0.03 mm over ten)
profile angle: 30° 15′ + 29° 55′ = 60° 10′; errors in the half-angles: +15′ and −5′
P = 1.503 mm; angle 60° 10′ with a slightly skewed profile. If the threads are long, the pitch error must be included in the virtual diameter (paragraph 35.1)

35.12 Conical gas and NPT threads

A tapered thread (ISO 7 R and Rc threads, ASME B1.20.1 NPT) has a diameter that increases by 1 mm every 16 mm (paragraph 17.8). Therefore, it does not have a single average diameter: the nominal diameter applies to a reference plane (measurement plane) at a fixed distance from the end of the pipe. To check it, one does not measure a diameter; instead, one checks where the reference plane lies.

  • For the external R thread, a conical ring is used: screw it onto the tube by hand and check where the end of the tube aligns with the narrow side of the ring. It must fall within a positional tolerance, which for small and medium sizes is approximately one turn (one pitch) around the face.
  • For the internal Rc thread, use a conical plug with a notch (or a step): screw it in by hand, and the face of the fillet must fall between the two edges of the notch, which mark the minimum and maximum positions.
  • For the NPT, “L1” ring and plug gauges are used, following the same criterion of a tolerance of plus or minus one turn in position after hand-tightening.
−1 lap+1 turnface of the gaugeR (tube)ringnotchplugRc (fillet)
Figure 35.15 · On the left, the conical ring on tube R: the end of the tube must fall within the green band, between one turn before and one turn after the face of the gauge. On the right, the plug with the notch in fillet Rc: the face of the fillet must fall between the two edges of the notch. Excessive taper.

Why do we measure in revolutions rather than in millimeters of diameter? Because on a cone, an error in diameter results in a displacement along the axis that is sixteen times larger and easier to see. One revolution shifts the fillet by one pitch along the axis, that is, by P/16 of the diameter.

Taper Ratio 1:16: Turns and Diameter
Δd = ΔL16 per revolution: Δd = P16
Δd change in diameter in mm · ΔL displacement along the axis in mm · P pitch in mm.
Example 35.17 · An R 1/2 pipe in the conical ring

The R 1/2 tapered ring (14 threads per inch) is screwed on by hand; the end of the tube protrudes 1.1 mm beyond the face of the ring. The tolerance is plus or minus one turn.

One revolution: P = 25.4 / 14 = 1.814 mm along the axis → tolerance ±1.814 mm
1.1 mm < 1.814 mm → within tolerance
In diameter: one turn equals 1.814 / 16 = 0.113 mm; the measured deviation equals 1.1 / 16 = 0.069 mm
Good: The thread is about 0.07 mm smaller in diameter than the nominal size, within 0.113 mm per turn

35.13 Measuring the threads on a CNC lathe

The best time to measure a thread is before removing the workpiece: as long as it is in the spindle, the probe can retrace the same groove, because it synchronizes each pass with the zero signal from the spindle encoder (paragraph 26.11). Once it has been removed, it is difficult to realign it. The method, used every day, is as follows:

  • In the program, you can insert an M00 stop (with a comment such as (CONTROLLO SUI FILI)) after the threading cycle, or you can run the cycle with a small amount of allowance (a few tenths of the diameter);
  • With the spindle stopped, clean the thread with compressed air and a brush, and measure it using the three threads (or a thread micrometer), holding the micrometer perfectly straight;
  • Calculate the difference between the measured dimension (Mmis) and the target dimension (Mob), which is usually the center of the tolerance range, shifted slightly toward the material maximum if you want to allow for insert wear;
  • Enter the correction into the wear compensator X of the threading tool (on Fanuc machines, on the OFFSET page, in the wear column; on Siemens machines, in the tool data) and repeat the cycle: the passes already made are dry cuts, and the last one removes the necessary amount;
  • It is remeasured; the threads are also checked at the end using the "passes/does not pass" ring.

The relationship between the correction and the measurement is one-to-one with respect to the diameter: when moving Δ in the X direction (along the diameter) with an insert that has the thread profile, the entire profile shifts toward the axis, and the average diameter decreases by exactly Δ. The dimensions on the threads also decrease by Δ, because in the formula, M and d₂ move together. The outside diameter, which was already turned before threading, remains unchanged.

Correction After Measuring the Wires
ΔX = −(Mmis − Mob ) Mob = d2max + d2min2 + 3 · df − 0.866025 · P
ΔX correction to be added to wear allowance X, to the diameter, in mm (negative = the tool cuts deeper) · Mmis reading taken from the wires · Mob target dimension · d2max, d2 min ranges of the average diameter · df wire diameter · P pitch · all in mm. If the control operates based on radius, the correction should be halved.
Example 35.18 · Machining an M20 × 2.5 screw on a lathe

The M20-6g threading program (example 26.13) stops with M00 after the G76 cycle. With 1.443 mm threads, the reading is M = 20.55 mm. By how much should this be corrected?

tolerance center: (18.334 + 18.164) / 2 = 18.249 mm → Mob = 18.249 + 2.164 = 20.413 mm
Mmis − Mob = 20.55 − 20.413 = 0.137 mm: the screw is still too large (M max is 20.498)
ΔX = −0.137 mm in diameter, or 0.069 mm in radius: a standard finishing pass
Enter −0.137 in the X-axis wear compensator, repeat the cycle, and measure again: the expected result is approximately 20.41 mm

If the first measurement had been less than 20.328 mm (M min), there would have been nothing to correct: the screw would already have to be discarded, because the material that has been removed cannot be restored. That is why the first measurement is always taken with an allowance.

✅
In mass production, the adjustment is made once and then monitored. Once the dimensions are set on the first workpiece, for the others, simply use the go/no-go ring; occasionally, remeasure on the threads and make a small adjustment to account for wear on the insert, which causes the average diameter to increase slowly. Recording the readings on a sheet of paper (or on a control chart, Chapter 38) indicates when to replace the insert before it falls out of tolerance.

35.14 Common Errors and Modern Systems

Errors in thread measurement are common in all workshops. Knowing what they are is the quickest way to avoid making them.

flat faces: it readsa slightly thicker wire: a warped anvilburra burr lifts the wire
Figure 35.16 · Three common errors. On the left, the flat-jaw micrometer resting on the ridges measures the outer diameter, not the average diameter. In the center, a wire thicker than the others tilts the anvil. On the right, a burr (in red) lifts the wire off the side.
  • Measure the outer diameter instead of the average diameter. A standard micrometer reading the ridges gives a value of d, which has a wide tolerance and says nothing about the fit.
  • Unequal wires. If a single wire is thicker than δ, the dimension of M increases by δ; if one of the two paired wires is thicker, the anvil tilts and the dimension of M increases by approximately δ/2. The calculated average diameter is larger than the actual value.
  • Wrong string. A string outside the playing area, or a string from another step, touches the top or bottom instead of the sides: the formula no longer applies.
  • The angle in the formula is incorrect. Using 3 and 0.866 (60°) on a 55° gas thread results in an error of tenths of a millimeter.
  • Burrs or debris on the thread. A burr on the flank, a chip, or coolant in the threading chamber can lift the thread or block the gauge: Clean the thread before measuring and, if necessary, deburr it with a threading file or a brush.
  • Force and alignment. Too much force crushes the files; a misaligned micrometer measures a slanted string (paragraph 31.12).
  • Just one point. A conical or oval thread may look good in one spot but not in another—it’s measured in multiple positions.
  • Forced gauge. The gauge fits when turned with the wrench, but the workpiece is defective and the gauge gets damaged.

Scanning Machines and Systems (Overview)

In metrology labs and mass production facilities, there are machines that do everything on their own. Contour profilometers run an arrow-shaped probe along the profile, on both flanks, and the software calculates pitch, angles, radii, and average diameter. Coordinate measuring machines (Chapter 37) measure threads using ball probes and dedicated programs. Optical shadow-casting machines photograph the profile of a rotating shaft and measure dozens of dimensions in just a few seconds. Universal measuring machines use the wire-and-ball method with controlled measuring force and temperature compensation. For hidden internal threads, X-ray tomography is also available. However, the principle remains the same as described in this chapter: the average diameter, pitch, and angle are derived from the profile and compared with the tolerances.

35.15 The Formulas in This Chapter

WhatFormula
Virtual Average Diameterd2v = d2s + fP + fα · fP = |ΔP| · cot(α/2) = 1.732 · |ΔP| (60°)
Step 1 of n stepsP = Ln / n · z = 25,4 / P
Optimal threaddott = P / (2 · cos(α/2)): 0.57735 · P (60°) · 0.56369 · P (55°) · 0.51764 · P (30°)
Useful field of view of the wire (60°)from 0.505 · P to 1.01 · P
Three files, general formulad2 = M − df · (1 + 1/sin(α/2)) + (P/2) · cot(α/2)
Three-file, metric, and UNd2 = M − 3 · df + 0,866025 · P
Three files: Whitworth and gasd2 = M − 3,165681 · df + 0,960491 · P
Three files, trapezoidald2 = M − 4,863703 · df + 1,866025 · P
Optimal Thread Pitch (metric)M = d2 + 0,866025 · P = d + 0,216506 · P
Propeller Trimtan ψ = Ph / (π · d2) · ΔM ≈ (df/2) · tan²ψ · cos(α/2) · cot(α/2) = 0.75 · df · tan²ψ (60°), to be subtracted from d2
Balls on an internal threadD2 = Mi + ds · (1 + 1/sin(α/2)) − (P/2) · cot(α/2) = Mi + 3 · ds − 0.866025 · P (60°)
1:16 scaleΔd = ΔL / 16 · one revolution: Δd = P / 16
LatheΔX = −(Mmis − Mob), at the diameter

35.16 Exercises

Try to solve them on your own, using a calculator, before looking at the solution. The 6g limits are those listed in the table in paragraph 35.8.

Exercise 1. Calculate the optimal thread for an M8 coarse-threaded screw and the M dimension indicated on a screw with a nominal mean diameter.
Solution

P = 1.25 mm; df = 0.57735 × 1.25 = 0.722 mm; d₂ = 8 − 0.649519 × 1.25 = 7.188 mm; M = 7.188 + 3 × 0.722 − 0.866025 × 1.25 = 7.188 + 2.166 − 1.083 = 8.272 mm.

Exercise 2. Given 1.010 mm-long files, within what range of dimensions must an M12-6g screw (d₂ between 10.679 and 10.829 mm) fall?
Solution

Constant: 3 · 1.010 − 0.866025 · 1.75 = 3.030 − 1.516 = 1.514 mm (1.5145). M max = 10.829 + 1.5145 = 12.344 mm; M min = 10.679 + 1.5145 = 12.194 mm.

Exercise 3. The same M12 screw is marked M = 12.30 mm. What is its average diameter? Is it acceptable?
Solution

d₂ = 12.30 − 1.5145 = 10.786 mm, between 10.679 and 10.829: good.

Exercise 4. On a screw with a diameter of approximately 12 mm, the caliper reads 17.48 mm between the first and eleventh peaks. What is its pitch? Could it be a thread with 14 threads per inch?
Solution

P = 17.48 / 10 = 1.748 mm → pitch 1.75: it’s an M12. With 14 threads per inch, ten pitches would measure 25.4 / 14 × 10 = 18.14 mm, which is 0.66 mm longer: it’s impossible to confuse them.

Exercise 5. A 1/2" BSW screw (Whitworth, 55°, 12 threads per inch, d = 12.7 mm). Calculate the pitch, the mean diameter (d₂ = d − 0.640327 · P), the optimal thread, and the nominal M dimension with that thread rounded to the nearest thousandth.
Solution

P = 25.4 / 12 = 2.1167 mm; d₂ = 12.7 − 0.640327 · 2.1167 = 12.7 − 1.355 = 11.345 mm; df = 0.56369 · 2.1167 = 1.193 mm; M = 11.345 + 3.165681 · 1.193 − 0.960491 · 2.1167 = 11.345 + 3.777 − 2.033 = 13.088 mm.

Exercise 6. An M16-6g screw (d₂ between 14.503 and 14.663 mm) measures d₂s = 14.600 mm along the threads and has a cumulative pitch error of 0.020 mm. Calculate the virtual mean diameter and explain what the P and NP rings will do.
Solution

fP = 1.732 × 0.020 = 0.035 mm; d₂v = 14.600 + 0.035 = 14.635 mm ≤ 14.663: the go gauge fits. d₂s = 14.600 ≥ 14.503: the no-go gauge does not fit. The screw is good.

Exercise 7. A thread micrometer, set to zero, reads 21.95 mm on an M24-6g screw. Is this within the acceptable range for the mean diameter?
Solution

For M24-6g: nominal d₂ 22.051 mm, es = −48 µm, Td2 = 200 µm → from 21.803 to 22.003 mm. 21.95 falls within the range: good.

Exercise 8. A Tr 20 × 4 screw has d₂ = 18 mm. Calculate the optimal pitch (rounded to the nearest thousandth), the M dimension without helix correction, and the helix correction.
Solution

df = 0.51764 · 4 = 2.071 mm. M = 18 + 4.863703 · 2.071 − 1.866025 · 4 = 18 + 10.073 − 7.464 = 20.609 mm. tan ψ = 4 / (π · 18) = 0.07074; ΔM = (2.071 / 2) · 0.07074² · 3.6049 = 1.0355 · 0.005004 · 3.6049 = 0.019 mm. Corrected expected dimension: 20.627 mm.

Exercise 9. On the lathe, an M10-6g screw measured with 0.866 mm files reads M = 10.35 mm. The goal is to reach the center of the tolerance. What correction should be entered in the wear compensator X?
Solution

Center: (8.994 + 8.862) / 2 = 8.928 mm; Mob = 8.928 + 1.299 = 10.227 mm. ΔX = −(10.35 − 10.227) = −0.123 mm at the diameter (0.062 mm at the radius).

Exercise 10. A conical gas thread R1 has 11 threads per inch. What is the tolerance of plus or minus one turn along the axis and on the diameter?
Solution

P = 25.4 / 11 = 2.309 mm: ±2.309 mm along the axis. For the diameter: 2.309 / 16 = 0.144 mm, that is, ±0.144 mm.

Exercise 11. When using a projector with a 50× objective lens, how large does one pitch of a fine M5 thread (0.75 mm) appear on the screen? If ten pitches measure 376.0 mm on the screen, what is the true pitch?
Solution

0.75 × 50 = 37.5 mm. True pitch: 376.0 / 50 / 10 = 0.752 mm.

Exercise 12. In a set of wires measuring 1.443 mm, the single wire (the one at the bottom) is worn down and measures 1.439 mm, but it is used as if it were 1.443 mm. By how much is the calculated average diameter incorrect, and in which direction?
Solution

The smallest single wire, at 0.004 mm, reduces the M dimension by 0.004 mm. The formula uses 1.443 for all three: the calculated d₂ is 0.004 mm smaller than the actual value. On a tolerance of 0.170 mm, this amounts to 2.4%—which is significant—and the wires are inspected at regular intervals just like other tools.

Exercise 13. Why does the gauge not pass through when it has only a few threads with a truncated profile? What would happen if the gauge were long and complete?
Solution

The non-pass gauge need only check the simple mean diameter. With only a few threads, pitch errors do not accumulate, and the truncated profile contacts only the flanks near d₂, not the crests or roots. A long, full-length non-pass gauge would jam even due to a pitch or outside diameter error, and would accept as good a screw with an average diameter that is too small (Taylor’s principle).