Threading Dimensions
A thread may have the correct outside diameter but still fail to screw in. What determines a proper fit is the mean diameter, along with the pitch and the flank angle—dimensions that cannot be measured with a slip gauge. In this chapter, we’ll look at all the tools used to measure these parameters—from thread counters to go/no-go gauges, from micrometers with tips to the three-wire method, all the way to profile projectors and thread inspection directly on a CNC lathe—with examples using actual screws.
35.1 What is measured in a thread?
A thread is a profile that repeats itself along a helix (Chapter 17). To determine whether it is correct, a single number is not enough: you need to know several measurements, and each requires its own tools. Before picking up a caliper, it’s best to know what you’re looking for and how important it is.
| Magnitude | What does it decide? | What is it measured with? |
|---|---|---|
| Outer diameter d (screw) or shank diameter D₁ (nut) | make sure the ridges do not touch the bottom of the other workpiece; the strength of the ridge | micrometer or caliper on the ridges; smooth P/NP pad for D₁ |
| Average diameter d₂ or D₂ | The clearance between the flanks: this is the primary dimension of the fit | three files, dial micrometer, thread gauges, balls |
| Core diameter d₃ of the screw | the screw's resistance and the clearance at the bottom | fine-tip micrometer, projector |
| Step P | that all the teeth fall into the compartments, even those far from the beginning | thread gauge, multi-step gauge, projector, microscope |
| Angle α and Profile Shape | that the sides match up along their entire height | thread gauge (visible), template projector, microscope |
| Taper (R and NPT gas threads) | the seal and the final position of the fillet | Tapered calipers with a scale, measuring the diameter at two points |
Of all these, the one that really matters is the average diameter, because the screw and nut come into contact along their flanks, not at their peaks. The outside diameter of a screw, on the other hand, has a wide tolerance and serves only to provide clearance at the bottom: a screw can measure 9.80 mm at the crests and still be perfectly acceptable, as we’ll see in Example 35.3. Anyone who checks a thread using a caliper only on the crests has, in practice, not checked it at all.
Simple Mean Diameter and Virtual Mean Diameter
The average diameter measured at a single point along the files is called the simple average diameter d₂s: it indicates how wide the file groove is at that position. But if the pitch is not exact, the teeth farther from the start no longer fall in the center of the nut’s slots and end up pressing against the side: to screw in, the bolt behaves as if it were larger. The same thing happens with an angular error. The diameter of a perfect lead screw—as long as the thread length—that mates exactly with the actual screw, including all its errors, is called the virtual mean diameter d₂v. This is what determines whether the screw will fit.
This gives rise to the rule for gauges, known as Taylor’s principle: a gauge that passes must check everything as a whole and over the entire length (i.e., the virtual diameter, at the maximum material limit), while a gauge that fails must check only a single dimension (the simple average diameter, at the minimum material limit). We will discuss this in Section 35.4.
An M12-6g screw, with its three threads, has a diameter d₂s = 10.700 mm. The projector shows a cumulative pitch error of 0.015 mm over the screw-in length. The angular errors are negligible. The 6g limits for the mean diameter are 10.679 and 10.829 mm (table in Section 35.8).
An M10-6g screw (d₂ between 8.862 and 8.994 mm) measures d₂s = 8.980 mm on the files, which is within the limits. However, the pitch has a cumulative error of 0.010 mm.
This is a classic example of someone saying, “I measured it with a feeler gauge and it’s good, but the nut won’t go on.” On a CNC lathe, pitch errors are rare; they are more likely to occur with rolled threads, on long workpieces that heat up during machining, and on screws made with worn-out machines.
35.2 Identifying a Thread: Thread Gauge and Thread Counter
Before measuring a thread accurately, you need to know what kind of thread it is. You can identify it in a matter of seconds using two simple tools (the complete procedure is described in section 17.14).
- The vernier caliper is used to measure the diameter. On the screw, the outside diameter is measured at the peaks: a metric screw always measures slightly less than the nominal value (for M10-6g, between 9.732 and 9.968 mm). Measure the core diameter D₁ in the hole and add approximately one pitch. If the diameter changes from one end to the other by about 1 mm every 16 mm, the thread is tapered.
- The thread gauge (also called a thread comb or pitch gauge). It consists of a set of comb-shaped steel strips, each with a thread profile and the pitch stamped on it. There is usually a metric set at 60° (pitch ranging from about 0.25 to 6 mm) and an inch-thread set, at 55° for Whitworth and gas threads or at 60° for standard threads (from about 4 to 60 threads per inch). Some models have both sets at opposite ends of the same case.
How to use the thread counter:
- Clean the thread of chips and oil, which fill the crevices and are misleading;
- Place the blade with its edge parallel to the screw's axis, in a plane that passes through the axis (when inserting it into a hole, start with the narrower end of the blade and hold it straight);
- Hold it up to the light: the correct blade fits into all the slots, covering at least six or eight teeth, without letting any light pass;
- If the light shifts more and more toward one end, the pitch is close but incorrect; if it passes equally on either side of each tooth, the pitch is correct but the angle is different (55° instead of 60°, or vice versa).
A screw measures 9.82 mm at the peaks; the metric tap from 1.5 to 60° fits without clearance on eight teeth. What kind of screw is this, and is its outer diameter correct?
35.3 Measuring Stride Length Over Ten Steps
When a thread counter isn't enough—or when there isn't one—the pitch is measured with a vernier caliper. It is never measured between two adjacent ridges, but between two ridges that are far apart: count eleven ridges, which make up ten pitches, read the distance between the first and the eleventh, and divide by ten. With a digital caliper, place the tips of the jaws on the ridges, or use a steel ruler with a magnifying glass; for a hole with threads, do the same on a plasticine impression or a cast.
There are two reasons for the ten steps. The first: the reading error (the gauge, the point where the tip rests, the eye) is always the same—a few hundredths—but when divided by ten, it becomes a few thousandths per step. Second: a slightly incorrect step adds up, and over ten steps, an imperceptible difference becomes nearly a millimeter.
A screw with a diameter of approximately 9.5 mm has a pitch that appears to be 1.5 mm. It could be a 3/8-16 UNC (P = 25.4 / 16). Between the first and eleventh threads, the caliper reads 15.02 mm.
35.4 Threaded go/no-go gauges
On the production line, no one measures every thread with a string; instead, they use threaded gauges (ISO 1502 standard), which do not provide a numerical value but rather a pass/fail result. For lead screws (threaded holes), the swab, for the screws, thering. Both have a "pass" side (P, or "GO") and a "no pass" side (NP, or "NO GO"), usually indicated by a red collar or band.
- The nut (P) has a full profile and is approximately as long as the screw-in length. It is machined to the maximum material limit of the workpiece (the largest permissible mean diameter for the screw, the smallest for the nut) and checks the entire assembly: the virtual mean diameter—that is, including pitch and angular errors—and ensures that the peaks and valleys do not interfere. It must screw in by hand, without forcing it, along the entire length of the thread.
- The non-passing (NP) thread is machined to the minimum material limit and has only two or three threads, with truncated crests and a relieved bottom. Thus, it contacts only the flanks, in a band near the mean diameter, and detects neither pitch errors (which do not accumulate with few threads) nor errors in the outer and core diameters. It checks only one dimension: the simple mean diameter. It can be screwed in for a maximum of two turns; if it goes in further, the thread is too wide (nut) or too narrow (screw).
If the "non-pass" were as long and complete as the "pass," a screw that is too thin but has a pitch error would get stuck in the "non-pass" because of the pitch and would be judged to be good: that is precisely what the truncated, short profile prevents.
| Skip | It doesn't go through | Review | What does that mean? |
|---|---|---|---|
| It all fits | It doesn't fit, or at most 2 turns | good | virtual and simple average diameter within the limits |
| It won't open, or it freezes up | doesn't fit | to be resumed | screw too large or nut too tight, or a pitch error, burrs, or chips in the thread |
| It all fits | enters more than 2 turns | discard | The screw is too thin or the nut is too large: the material that has been removed cannot be restored |
| doesn't fit | enter | check everything | Severely deformed thread (oval, conical) or mixed thread sizes: measured using threads |
Check the three M10-6g screws with the P and NP washers.
35.5 Adjustable rings, feeler gauges, and roller forks
It is not easy to measure the inside diameter of a threaded ring. For this reason, go rings are almost always adjustable: they have a radial slot and one or more screws that open or close them by a few hundredths. They are adjusted against a setting plug—a precision threaded plug calibrated in the metrology lab. The setting plug usually has one section with the full profile, against which the ring is adjusted along its sides, and another section with truncated ridges, which allows one to verify that the ring has been adjusted along its sides and not at the bottom. Once the ring is adjusted, the screws are locked in place and sealed with a drop of varnish: if the seal is broken, the ring must be rechecked.
When inspecting hundreds of screws a day, turning a ring is too slow. Instead, a roller fork gauge is used: a C-shaped frame with two pairs of threaded rollers (or with annular grooves spaced at regular intervals), one pair that the screw passes through at the entrance and one pair that the screw no longer passes through inside. The screw is pushed inside without being turned: it must pass over the “pass” rollers and stop on the “fail” rollers. The rollers rotate on the screw without scratching it. There are also roller gauges equipped with a dial indicator, which, in addition to indicating “pass” or “fail,” show how much the average diameter deviates from the set value—useful for monitoring the machine (Chapter 38).
35.6 The thread micrometer
A thread micrometer is a standard micrometer with two special tips: on the anvil, a V-shaped insert that straddles a tooth; on the stem, a conical tip that enters the opposite groove. The tips contact the flanks near the mean diameter, and the micrometer reads d₂ directly, without any calculations. The tips are interchangeable, and each pair covers a specific pitch range (for example, from 0.4 to 0.5 mm, from 0.6 to 0.9, from 1 to 1.75, from 2 to 3, from 3.5 to 5): with the wrong pair, the contact point falls far from d₂, and the reading is invalid.
The rule for zeroing is simple: every time you change the tips, you must reset the zero. On a 0–25 mm micrometer, bring the tips into contact with each other (the cone enters the V-notch) and set the reading to zero. On larger micrometers (25 to 50 mm, 50 to 75 mm), use a reference bar with shaped ends, as long as the initial range: the reading must match the value marked on the gauge; if it does not, adjust the zero or account for the difference.
The thread micrometer is convenient and fast, but it contacts the threads at only two points, detects angular errors, and its tips wear out. With an indicative uncertainty of 0.01 mm, according to the rule of tenths (paragraph 31.8), it is suitable for average diameter tolerances of 0.1 mm and above: this applies to 6g threads from M10 and up, and is borderline for smaller ones. For more precise inspections, the three-wire gauge is used.
A M16-6g screw (P = 2 mm) is measured using the 2- to 3-mm tips. The micrometer, set to zero, reads 14.690 mm.
A micrometer for threads ranging from 25 to 50 mm, when used on the 25-mm reference bar, reads 25.006 mm. When used on an M30-6g screw (P = 3.5 mm), it reads 27.640 mm. For the M30, the standard specifies es = −53 µm and Td2 = 212 µm.
35.7 The Three-File Method: Principle and Optimal File
The three-wire method, introduced as a calculation in Section 6.11, is the most accurate way to measure the average diameter in a workshop. Three hardened and ground steel wires, all of the same diameter df (in Chapter 6 we referred to it as dw), are placed in the threads: two on one side, in two adjacent grooves, and one on the opposite side, in the middle groove. Using a flat-face micrometer (or a dial indicator on a workbench), measure the dimension M above the wires. Each wire touches the two flanks of its groove, and its position depends solely on the width of the groove; for this reason, the average diameter can be determined from M.
The figure shows the formula in three steps. The center of the wire lies on the bisector of the slot: the distance from the vertex is the radius of the wire divided by the sine of the half-angle, a = df / (2 · sin α/2). The mean diameter is located where the slot is half a pitch wide, that is, at b = (P/4) · cot(α/2) from the vertex. Half of the dimension M, measured from the screw axis to the top of the file, is then d₂/2 − b + a + df/2. Multiplying by two:
The Optimal Thread
The formula applies to any thread that touches both flanks and protrudes from the ridges. But there is one diameter that is better than the others: the one that touches the flanks exactly at the mean diameter. This is the optimal thread (also called the best thread). With this thread, a small error in the thread angle has almost no effect on the measurement, because the point of contact remains fixed while the flank rotates around that point; and the contact occurs on the smoothest part of the flank, far from the crest and fillet transitions.
For the 60° profile, you can check it by hand: the point of contact lies 0.75 · df above the vertex V, and the mean diameter lies at 0.433 · P; the two coincide if df = 0.433 / 0.75 · P = 0.577 · P. Files are sold in sets, with diameters close to the optimal values for the most common pitches; for a pitch that does not have its own file, use the one closest to the optimal value, provided it falls within the usable range, and calculate using its actual diameter.
35.8 The average diameter measured from the dimensions on the wires
By substituting the profile angle into the general formula, we obtain ready-made formulas for the most common threads. For metric threads, the two coefficients are whole numbers: 1 + 1/sin 30° = 3 and (1/2) · cot 30° = 0.866025.
The table provides, for coarse-pitch metric threads, the optimal thread size rounded to the nearest thousandth and the expected M dimensions: for the nominal d₂ and for the two limits of class 6g. The dimensions are calculated using the rounded thread value from the table; if your thread is different, recalculate using the formula. The deviations es and the tolerances Td2 are those specified in ISO 965-1, derived as described in paragraph 17.5.
| Thread | P (mm) | nominal d₂ | df wire | M for nominal d₂ | 6 g: d₂ max / min | M max (6g) | M min (6g) |
|---|---|---|---|---|---|---|---|
| M6 | 1 | 5,350 | 0,577 | 6,215 | 5,324 / 5,212 | 6,189 | 6,077 |
| M8 | 1,25 | 7,188 | 0,722 | 8,272 | 7,160 / 7,042 | 8,244 | 8,126 |
| M10 | 1,5 | 9,026 | 0,866 | 10,325 | 8,994 / 8,862 | 10,293 | 10,161 |
| M12 | 1,75 | 10,863 | 1,010 | 12,378 | 10,829 / 10,679 | 12,344 | 12,194 |
| M14 | 2 | 12,701 | 1,155 | 14,434 | 12,663 / 12,503 | 14,396 | 14,236 |
| M16 | 2 | 14,701 | 1,155 | 16,434 | 14,663 / 14,503 | 16,396 | 16,236 |
| M18 | 2,5 | 16,376 | 1,443 | 18,540 | 16,334 / 16,164 | 18,498 | 18,328 |
| M20 | 2,5 | 18,376 | 1,443 | 20,540 | 18,334 / 18,164 | 20,498 | 20,328 |
| M22 | 2,5 | 20,376 | 1,443 | 22,540 | 20,334 / 20,164 | 22,498 | 22,328 |
| M24 | 3 | 22,051 | 1,732 | 24,649 | 22,003 / 21,803 | 24,601 | 24,401 |
Values in mm, recalculated by CNC Simulator Italia using d₂ = d − 0.649519 · P, df = 0.57735 · P (rounded), and M = d₂ + 3 · df − 0.866025 · P, without helix correction (1.5 to 2.5 µm for these threads). The standard takes precedence.
Check the M20-6g screw from Example 26.13, which has files measuring 1.443 mm. What dimensions would you expect, and what does a reading of 20.45 mm indicate?
The screw in Example 6.17, which measures 20.50 mm, has d₂ = 20.50 − 2.164 = 18.336 mm: it exceeds the 2 µm limit. With an uncertainty of a few micrometers, it falls into the gray area described in paragraph 31.9: the supplier cannot declare it acceptable, but a final light pass will bring it up to standard.
0.866 mm files on an M10-6g screw. The measurement is 10.24 mm.
There's only one 0.895 mm set in the workshop. Can it be used on the M10? What is the marked value on a screw with a nominal d₂, and what is the d₂ of a screw marked 10.330 mm?
The G1/2 external thread has a diameter (d) of 20.955 mm and 14 threads per inch (paragraph 17.7). With 1.023 mm wires, M = 21.10 mm. According to ISO 228-1, the average diameter may be up to 0.142 mm below the nominal value in Class A and up to 0.284 mm below in Class B.
The drawing specifies d₂ between 21.150 and 21.400 mm (example values; for Class 7e, the limits are specified in ISO 2903). Wires measuring 2.588 mm; reading M = 24.55 mm.
35.9 How to Take Measurements Using Strings
The formula is simple; the challenge lies entirely in threading the wires and reading the measurements carefully. Three thin wires that slip through your fingers as you tighten the micrometer are the classic test of a metrologist’s patience. Here’s how it’s done.
- Wires from a single set. The three wires must come from the same set: they are identical to within a few tenths of a micrometer, and their actual diameter is specified on the certificate. A worn wire or one from a different set will result in an incorrect measurement (paragraph 35.14).
- Wire holder. The wires are held in place by a support: small collets or clips attached to the micrometer, or a wire holder that allows them to hang in front of the faces. The wire must be free to align itself with the slot: if it is forced perpendicular to the screw axis, it will be off by tens of micrometers.
- Micrometer on the stand. The micrometer is secured to its stand; the screw is held by hand or between the tips, and the faces must be flat and parallel: the faces of the micrometer must rest on the two wires on one side and on the other wire on the other side.
- Apply a low, constant force. The wire should touch the side along a straight line: if too much force is applied, it will compress elastically and the measurement will decrease. Use a ratchet or a constant-force device. The recommended forces are a few newtons, lower for thin wires (roughly 1 to 3 N for wires less than one millimeter in diameter, up to about ten newtons for thicker ones); the exact values can be found in the standards and in the kit’s instructions.
- More points. Measurements are taken at at least three points along the thread (start, middle, end) and in two directions at 90°: the differences indicate whether the thread is conical or oval.
- Temperatures. The workpiece, wires, and micrometer must be at the same temperature (paragraph 31.10): a screw that has just been removed from the lathe is larger than it is at 20 °C.
Correction for Propeller Pitch (Overview)
The three-thread formula envisions an annular cavity, closed in on itself like a groove. The actual cavity is a helix: the thread, which is straight, rests against the flanks at points that are no longer in the axial plane and stops slightly higher up. The M dimension becomes slightly larger, and the mean diameter calculated using the simple formula is slightly greater than the actual value. For 60° threads with a single start, the effect is one or two micrometers; for coarse pitches, trapezoidal threads, and multi-start threads, it becomes significant.
35.10 Two-wire, core diameter and internal threads
The Two-File Method (Overview)
It can also be measured using just two wires, one on each side. However, the two opposite slots are offset by half a pitch, and the faces of the micrometer are angled; the dimension obtained is slightly different from that obtained with three wires and must be corrected using a formula that depends on the pitch and the diameter. For this reason, the three wires are used whenever possible. The two wires (or two balls) are used where there is no room for the third wire—on very short screws and in two-point instruments.
The core diameter
The d₃ diameter of the vine is measured using the dial micrometer (thin conical points or blades that reach the bottom of the cavity) or to the projector. On the lead screw, the D₁ core is the cylindrical portion of the threads: it is checked using a smooth plug gauge (pass or fail) or a bore gauge (Chapter 32), just like any other hole.
The average diameter of the internal threads
Threads cannot be held inside a hole. In production, the P/NP threaded gages described in paragraph 35.4 are used. For measurement, however, three-point internal micrometers with threaded heads (three sectors with a thread profile that widen until they touch the flanks) and internal thread comparators, with two jaws calibrated to a reference ring, are used. In the metrology lab, the ball method is used: two balls of optimal diameter, mounted on two arms, are inserted into the opposite bores, and the distance Mi between their innermost points is measured.
0.866-mm balls in an M10-6H lead screw; the dial indicator reads Mi = 7.73 mm. For the 6H, the average diameter ranges from 9.026 mm (the nominal value) to 9.206 mm.
35.11 The profile projector and the workshop microscope
The profile projector illuminates the workpiece from behind and projects its magnified shadow onto a frosted glass screen, 300 to 600 mm wide or more. The lenses provide magnifications of 10, 20, 50, or 100 times. The workpiece rests on a coordinate table that moves in micrometer increments; the screen rotates and has an angular scale with readings in minutes of a degree. On the thread, one can see the pitch, the angle, the crest and root radii, the burrs, and the shape of the profile.
- Using templates. A transparent template with the thread profile drawn to scale (60°, 55°, trapezoidal)—often including the tolerance band—is placed on the screen. You check to see if the shadow falls within the tolerance band: this is a quick visual comparison check.
- Angle measurement. Align the crosshairs with one side, read the angle, then do the same with the other side: this gives you the two half-angles, each relative to the perpendicular to the axis. A thread may have the correct total angle but different half-angles (a “crooked” profile), and this can only be detected in this way.
- Measuring the pitch. Align one side with the crosshairs, then move the plate until the corresponding side ten steps further along aligns with the same line, and read the displacement: this is the measurement over ten steps described in paragraph 35.3, but taken with a micrometer.
- Helix angle. Light passes through the chamber, which is tilted by the helix angle ψ: if the workpiece remains upright, one side casts a shadow on the other, and the profile appears blurred and distorted. Tilt the light head (or the workpiece, on the swivel tips) by an angle ψ, and the profile becomes sharp.
The workshop microscope (or measuring microscope) performs the same functions, but the user looks through the eyepiece instead of at a screen: magnifications ranging from 10x to 50x, an eyepiece with a reticle, and a goniometric head for measuring angles, as well as a coordinate stage with micrometer screws or optical scales. It is smaller and more precise than the projector when used on small workpieces; here, too, the workpiece is tilted by the helix angle.
An M10 × 1.5 screw is mounted on the projector with the 20× objective lens. On the screen, ten steps measured using the scale total 300.6 mm. The semi-angles read are 30° 15′ and 29° 55′.
35.12 Conical gas and NPT threads
A tapered thread (ISO 7 R and Rc threads, ASME B1.20.1 NPT) has a diameter that increases by 1 mm every 16 mm (paragraph 17.8). Therefore, it does not have a single average diameter: the nominal diameter applies to a reference plane (measurement plane) at a fixed distance from the end of the pipe. To check it, one does not measure a diameter; instead, one checks where the reference plane lies.
- For the external R thread, a conical ring is used: screw it onto the tube by hand and check where the end of the tube aligns with the narrow side of the ring. It must fall within a positional tolerance, which for small and medium sizes is approximately one turn (one pitch) around the face.
- For the internal Rc thread, use a conical plug with a notch (or a step): screw it in by hand, and the face of the fillet must fall between the two edges of the notch, which mark the minimum and maximum positions.
- For the NPT, “L1” ring and plug gauges are used, following the same criterion of a tolerance of plus or minus one turn in position after hand-tightening.
Why do we measure in revolutions rather than in millimeters of diameter? Because on a cone, an error in diameter results in a displacement along the axis that is sixteen times larger and easier to see. One revolution shifts the fillet by one pitch along the axis, that is, by P/16 of the diameter.
The R 1/2 tapered ring (14 threads per inch) is screwed on by hand; the end of the tube protrudes 1.1 mm beyond the face of the ring. The tolerance is plus or minus one turn.
35.13 Measuring the threads on a CNC lathe
The best time to measure a thread is before removing the workpiece: as long as it is in the spindle, the probe can retrace the same groove, because it synchronizes each pass with the zero signal from the spindle encoder (paragraph 26.11). Once it has been removed, it is difficult to realign it. The method, used every day, is as follows:
- In the program, you can insert an
M00stop (with a comment such as(CONTROLLO SUI FILI)) after the threading cycle, or you can run the cycle with a small amount of allowance (a few tenths of the diameter); - With the spindle stopped, clean the thread with compressed air and a brush, and measure it using the three threads (or a thread micrometer), holding the micrometer perfectly straight;
- Calculate the difference between the measured dimension (Mmis) and the target dimension (Mob), which is usually the center of the tolerance range, shifted slightly toward the material maximum if you want to allow for insert wear;
- Enter the correction into the wear compensator X of the threading tool (on Fanuc machines, on the OFFSET page, in the wear column; on Siemens machines, in the tool data) and repeat the cycle: the passes already made are dry cuts, and the last one removes the necessary amount;
- It is remeasured; the threads are also checked at the end using the "passes/does not pass" ring.
The relationship between the correction and the measurement is one-to-one with respect to the diameter: when moving Δ in the X direction (along the diameter) with an insert that has the thread profile, the entire profile shifts toward the axis, and the average diameter decreases by exactly Δ. The dimensions on the threads also decrease by Δ, because in the formula, M and d₂ move together. The outside diameter, which was already turned before threading, remains unchanged.
The M20-6g threading program (example 26.13) stops with M00 after the G76 cycle. With 1.443 mm threads, the reading is M = 20.55 mm. By how much should this be corrected?
If the first measurement had been less than 20.328 mm (M min), there would have been nothing to correct: the screw would already have to be discarded, because the material that has been removed cannot be restored. That is why the first measurement is always taken with an allowance.
35.14 Common Errors and Modern Systems
Errors in thread measurement are common in all workshops. Knowing what they are is the quickest way to avoid making them.
- Measure the outer diameter instead of the average diameter. A standard micrometer reading the ridges gives a value of d, which has a wide tolerance and says nothing about the fit.
- Unequal wires. If a single wire is thicker than δ, the dimension of M increases by δ; if one of the two paired wires is thicker, the anvil tilts and the dimension of M increases by approximately δ/2. The calculated average diameter is larger than the actual value.
- Wrong string. A string outside the playing area, or a string from another step, touches the top or bottom instead of the sides: the formula no longer applies.
- The angle in the formula is incorrect. Using 3 and 0.866 (60°) on a 55° gas thread results in an error of tenths of a millimeter.
- Burrs or debris on the thread. A burr on the flank, a chip, or coolant in the threading chamber can lift the thread or block the gauge: Clean the thread before measuring and, if necessary, deburr it with a threading file or a brush.
- Force and alignment. Too much force crushes the files; a misaligned micrometer measures a slanted string (paragraph 31.12).
- Just one point. A conical or oval thread may look good in one spot but not in another—it’s measured in multiple positions.
- Forced gauge. The gauge fits when turned with the wrench, but the workpiece is defective and the gauge gets damaged.
Scanning Machines and Systems (Overview)
In metrology labs and mass production facilities, there are machines that do everything on their own. Contour profilometers run an arrow-shaped probe along the profile, on both flanks, and the software calculates pitch, angles, radii, and average diameter. Coordinate measuring machines (Chapter 37) measure threads using ball probes and dedicated programs. Optical shadow-casting machines photograph the profile of a rotating shaft and measure dozens of dimensions in just a few seconds. Universal measuring machines use the wire-and-ball method with controlled measuring force and temperature compensation. For hidden internal threads, X-ray tomography is also available. However, the principle remains the same as described in this chapter: the average diameter, pitch, and angle are derived from the profile and compared with the tolerances.
35.15 The Formulas in This Chapter
| What | Formula |
|---|---|
| Virtual Average Diameter | d2v = d2s + fP + fα · fP = |ΔP| · cot(α/2) = 1.732 · |ΔP| (60°) |
| Step 1 of n steps | P = Ln / n · z = 25,4 / P |
| Optimal thread | dott = P / (2 · cos(α/2)): 0.57735 · P (60°) · 0.56369 · P (55°) · 0.51764 · P (30°) |
| Useful field of view of the wire (60°) | from 0.505 · P to 1.01 · P |
| Three files, general formula | d2 = M − df · (1 + 1/sin(α/2)) + (P/2) · cot(α/2) |
| Three-file, metric, and UN | d2 = M − 3 · df + 0,866025 · P |
| Three files: Whitworth and gas | d2 = M − 3,165681 · df + 0,960491 · P |
| Three files, trapezoidal | d2 = M − 4,863703 · df + 1,866025 · P |
| Optimal Thread Pitch (metric) | M = d2 + 0,866025 · P = d + 0,216506 · P |
| Propeller Trim | tan ψ = Ph / (π · d2) · ΔM ≈ (df/2) · tan²ψ · cos(α/2) · cot(α/2) = 0.75 · df · tan²ψ (60°), to be subtracted from d2 |
| Balls on an internal thread | D2 = Mi + ds · (1 + 1/sin(α/2)) − (P/2) · cot(α/2) = Mi + 3 · ds − 0.866025 · P (60°) |
| 1:16 scale | Δd = ΔL / 16 · one revolution: Δd = P / 16 |
| Lathe | ΔX = −(Mmis − Mob), at the diameter |
35.16 Exercises
Try to solve them on your own, using a calculator, before looking at the solution. The 6g limits are those listed in the table in paragraph 35.8.
Solution
P = 1.25 mm; df = 0.57735 × 1.25 = 0.722 mm; d₂ = 8 − 0.649519 × 1.25 = 7.188 mm; M = 7.188 + 3 × 0.722 − 0.866025 × 1.25 = 7.188 + 2.166 − 1.083 = 8.272 mm.
Solution
Constant: 3 · 1.010 − 0.866025 · 1.75 = 3.030 − 1.516 = 1.514 mm (1.5145). M max = 10.829 + 1.5145 = 12.344 mm; M min = 10.679 + 1.5145 = 12.194 mm.
Solution
d₂ = 12.30 − 1.5145 = 10.786 mm, between 10.679 and 10.829: good.
Solution
P = 17.48 / 10 = 1.748 mm → pitch 1.75: it’s an M12. With 14 threads per inch, ten pitches would measure 25.4 / 14 × 10 = 18.14 mm, which is 0.66 mm longer: it’s impossible to confuse them.
Solution
P = 25.4 / 12 = 2.1167 mm; d₂ = 12.7 − 0.640327 · 2.1167 = 12.7 − 1.355 = 11.345 mm; df = 0.56369 · 2.1167 = 1.193 mm; M = 11.345 + 3.165681 · 1.193 − 0.960491 · 2.1167 = 11.345 + 3.777 − 2.033 = 13.088 mm.
Solution
fP = 1.732 × 0.020 = 0.035 mm; d₂v = 14.600 + 0.035 = 14.635 mm ≤ 14.663: the go gauge fits. d₂s = 14.600 ≥ 14.503: the no-go gauge does not fit. The screw is good.
Solution
For M24-6g: nominal d₂ 22.051 mm, es = −48 µm, Td2 = 200 µm → from 21.803 to 22.003 mm. 21.95 falls within the range: good.
Solution
df = 0.51764 · 4 = 2.071 mm. M = 18 + 4.863703 · 2.071 − 1.866025 · 4 = 18 + 10.073 − 7.464 = 20.609 mm. tan ψ = 4 / (π · 18) = 0.07074; ΔM = (2.071 / 2) · 0.07074² · 3.6049 = 1.0355 · 0.005004 · 3.6049 = 0.019 mm. Corrected expected dimension: 20.627 mm.
Solution
Center: (8.994 + 8.862) / 2 = 8.928 mm; Mob = 8.928 + 1.299 = 10.227 mm. ΔX = −(10.35 − 10.227) = −0.123 mm at the diameter (0.062 mm at the radius).
Solution
P = 25.4 / 11 = 2.309 mm: ±2.309 mm along the axis. For the diameter: 2.309 / 16 = 0.144 mm, that is, ±0.144 mm.
Solution
0.75 × 50 = 37.5 mm. True pitch: 376.0 / 50 / 10 = 0.752 mm.
Solution
The smallest single wire, at 0.004 mm, reduces the M dimension by 0.004 mm. The formula uses 1.443 for all three: the calculated d₂ is 0.004 mm smaller than the actual value. On a tolerance of 0.170 mm, this amounts to 2.4%—which is significant—and the wires are inspected at regular intervals just like other tools.
Solution
The non-pass gauge need only check the simple mean diameter. With only a few threads, pitch errors do not accumulate, and the truncated profile contacts only the flanks near d₂, not the crests or roots. A long, full-length non-pass gauge would jam even due to a pitch or outside diameter error, and would accept as good a screw with an average diameter that is too small (Taylor’s principle).