Geometric Tolerance Inspection
Chapter 15 taught us how to read geometric tolerance symbols; here we’ll learn how to actually check them on the workbench. For each tolerance, we’ll see what to measure, how to mount the workpiece on the reference surface, on V-blocks, between the tailstocks, or on a mandrel; where to place the dial indicator; what readings to take; and how to determine whether the workpiece is “good” or “rejected.” Each method is illustrated with an example featuring realistic measurements and a comparison with a coordinate measuring machine. At the end of the chapter, you’ll find the most common mounting errors and a table summarizing everything.
34.1 From the Drawing to the Test Bench
Each geometric tolerance defines a zone: two lines, two planes, two circles, or a cylinder (Chapter 15). Checking the tolerance means determining whether the actual part falls entirely within that zone. In practice, the zone is not drawn on the workpiece: a certain number of measurements are taken, and the width of the smallest zone that contains them is calculated; this is then compared with the value in the table.
Tolerances for orientation, position, and runout have one or more reference points. A reference point is an ideal element (a perfect plane, a perfect axis), whereas the actual surface of the workpiece is not perfect. In the workshop, the reference point is simulated using equipment that is much more precise than the workpiece itself:
- reference surface: simulates a reference plane; the workpiece rests on it with the face indicated by the letter (see Chapter 31 for granite and cast-iron surfaces);
- V-prisms (V-blocks): These simulate the axis of an external pin; the pin rests on two generatrices, and its axis remains stationary while it is rotated;
- tailstocks: they simulate the axis defined by the two centers of the workpiece, just like on a lathe;
- expandable spindle and center pin: these simulate the axis of a hole; the pin is selected with no clearance, and the spindle expands inside the hole to center it;
- square, cylinder square, sine plane: they provide a known orientation (90° or a specific angle) relative to the plane;
- parallel-plane blocks: provide a known height, either to zero the comparator or to tilt the sine plane.
What You'll Find on the Comparison Site
The primary instrument is the dial indicator (rod-type or lever-type) mounted on a stand, as described in Chapter 32. In geometric inspection, what matters is not the reading at a single point, but the difference between the maximum and minimum readings during a displacement or rotation of the workpiece: the needle’s travel. For this reason, the dial indicator is zeroed wherever it happens to be, with a small preload (half a turn or one turn of the dial), and then the readings are recorded along with their sign.
But be careful: the excursion isn't always the value to compare with the tolerance. Sometimes it should be taken as a whole, sometimes as half, and sometimes it should be multiplied by a factor or converted to a different length.
| Check | What is the opposite of tolerance? |
|---|---|
| Straightness, flatness, parallelism, perpendicularity, inclination | the total runout (after correcting for the inclination, within the dimensional tolerances) |
| Radial, axial, and total runout | The entire hike in one complete loop |
| Eccentricity of a diameter | halfway through the hike |
| Coaxiality and Concentricity (Ø Zone) | twice the eccentricity, that is, the full stroke if the diameter is circular |
| Symmetry with the workpiece rotated 180° | the difference between the two readings (i.e., 2e; compare with t) |
| Circularity on the V-prism | the excursion divided by the prism factor (paragraph 34.4) |
| Alignment measured using a pin that is longer than the hole | the deflection relative to the hole length |
A shaft has a perfectly round diameter but is mounted crookedly: its axis is offset from the reference axis A. With the workpiece in the centers, the dial indicator reads from −0.012 to +0.028 mm over one complete revolution.
In addition to workshop methods, there is always the alternative of a coordinate measuring machine (abbreviated as CMM, Chapter 37): the machine touches the workpiece at many points, constructs the geometric elements (planes, circles, cylinders, axes), simulates the reference points through calculation, and compares the deviation to the tolerance zone. It is more comprehensive and does not depend on the operator’s skill, but it is expensive, is housed in a metrology lab, and requires a program. In each section, we will explain how to perform the same inspection using a CMM.
34.2 Straightness
Straightness checks a line on the surface (a generatrix, the edge of a guide) or an axis. Without a reference, the area can be rotated as needed: it doesn’t matter if the line is slanted; what matters is only how much it deviates from a straight line. This is the key point to remember when doing the calculations: the tilt of the workpiece on the table must be subtracted from the readings.
Knife-Cut Line and Thickness Gauge
This is the simplest method. Place a knife-edge ruler (a precision ruler with a sharp edge that leaves a thin line) against the surface and look at it against the light: where the surface is lower, a sliver of light passes through. With a little practice, the eye can detect gaps as small as a few micrometers, because the light changes color when the gap falls below 2 or 3 µm. To quantify the deviation, insert the gauges of a thickness gauge into the gap: the thickest one that fits and the thinnest one that does not define the deviation.
A 500-mm-long sled guide has straightness 0,05. With the knife edge resting on top, you can see light in the center. The 0.03 mm sheet fits through, but the 0.04 mm sheet does not.
The method works well when the surface is concave (the straightedge rests on the ends). If it is convex, the straightedge sways at the highest point: rest it on one end and measure the gap at the other, then do the opposite. The ruler itself has an error specified based on its grade and must not bend under its own weight: for long rulers, it is supported on two identical blocks at the points where deflection is minimal, approximately 0.22 times the length from each end.
Guide-mounted comparator
To obtain accurate measurements, place the workpiece on two identical blocks near its ends on the reference surface, and slide a dial indicator mounted on a support along the line to be checked; the support moves on the surface or along a ground guide. Take readings at regular intervals, for example, every 50 mm. The procedure:
- Clean the surface, the blocks, and the workpieces; place the workpiece on the surface and mark the measurement points with a marker;
- zero the comparator at the first point and read all the others, noting the sign;
- To correct for slope in the readings: Draw a straight line connecting the first and last readings, and subtract the value of the line at that point from each reading;
- Straightness is the difference between the highest and lowest deviations, as corrected.
Required straightness: 0.015 mm. Readings every 50 mm, in µm: 0, +4, +9, +11, +14, +12, +10, +8, +6.
Autocollimator and Electronic Level (Overview)
A different method is used on the long guideways of machine tools: a mirror mounted on a base of fixed length (for example, 100 mm) is moved in increments along the guide, and an autocollimator (a telescope that measures the angle of a mirror) or an electronic level measures how much the base tilts at each increment. Each angle, multiplied by the length of the base, gives the height difference for that step; by summing the height differences, the profile is reconstructed, which is then treated in the same way as that of the dial indicator. As a rough estimate, one arcsecond on a 100-mm base is equivalent to approximately 0.5 µm.
34.3 Flatness
Flatness requires that the entire surface lie between two parallel planes separated by a distance t, which may be inclined as appropriate. The most common error is to rest the workpiece on the reference surface and slide the dial indicator over the upper face: this measures the parallelism between the two faces, not the flatness of one of them (paragraph 34.7).
The three-point shot
The workshop method is as follows: the workpiece is supported on three jacks (adjustable screw-type supports), with the surface to be checked facing upward. Three points define a plane: the jacks are adjusted until the dial indicator reads zero at three points on the surface chosen to be far apart, usually three corners. At that point, the reference plane and the plane defined by the three points are parallel, and the dial indicator measures the deviation of the surface from the plane defined by the three points. The other points on a grid marked on the workpiece are then read.
200 × 120 mm plate, flatness 0,015. Adjust the jacks until points 1, 3, and 7 read 0. Readings for the other points, in µm: point 2 +3, point 4 +5, point 5 +8, point 6 +2, point 8 +1, point 9 −4.
The three-point plane is not the best plane: by tilting the reference plane slightly, the calculations of the minimum area based on the same nine readings yield 10 µm. Therefore, the measured value is an upper limit: if it falls within the tolerance, the workpiece is definitely acceptable; if it is slightly outside the tolerance, before rejecting it, the calculation must be redone using the best reference plane (either on a computer or with a CMM).
On large surfaces (reference planes, benches), a finer grid is used, with measurements taken along the sides, centerlines, and diagonals, often using an electronic level instead of a dial indicator: this is the so-called “English flag” method, named for the drawing of the measurement lines.
Optical Glass and Fringes (An Overview)
For lapped surfaces (the faces of blocks, micrometers, and seals), differences of one-tenth of a micrometer cannot be seen with a dial indicator. A flat optical glass plate—a glass or quartz disc machined to within a few hundredths of a micrometer—is placed against the surface and illuminated with light of a single color (monochromatic). A very thin layer of air remains between the glass and the workpiece: the light reflected from the two surfaces interferes, causing dark and light fringes to appear. As one moves from one fringe to the next, the thickness of the air gap changes by half a wavelength: with yellow sodium light (approximately 0.59 µm), one fringe corresponds to about 0.3 µm.
The sealing surface of a ring, with a flatness of 0.001 mm (1 µm), shows three concentric rings on the optical glass. Another surface shows nearly straight fringes that curve by half the center-to-center distance.
34.4 Circularity
The circularity check ensures, in every section perpendicular to the axis, that the contour lies between two concentric circles with radii that differ by t. This is a difference in radii, measured relative to a center—and this is where the trouble begins, because workshop tools do not measure radii.
The micrometer detects only the even lobes
The micrometer measures the diameter between two opposite points. An oval cross-section (two lobes) has a maximum and a minimum diameter, and the micrometer can measure it accurately: the difference in diameters is twice the difference in radii. However, a section with an odd number of lobes (three, five, seven) has the same diameter in all directions, because each lobe corresponds to a valley on the opposite side. This is the shape that often results from centerless grinding and clamping on three-jaw spindles.
The comparator on the V-prism
If the workpiece rests in a V-shaped prism and the comparator touches the top, on the bisector of the V, as the workpiece rotates, the odd lobes become visible: when there is a lobe at the top, there are two valleys below, and the workpiece “sinks” slightly; when there is a valley at the top, the workpiece rests on two lobes. The center of the workpiece shifts, and the comparator adds the shift in the center to the change in radius. However, the reading does not represent circularity: it must be divided by a prism factor F, which depends on the angle of the V and the number of lobes.
| Lobi n | Two points (micrometer) | 60° Prism | 90° Prism | 120° Prism |
|---|---|---|---|---|
| 2 (oval) | 2 | 0 | 1 | 1,58 |
| 3 | 0 | 3 | 2 | 1 |
| 4 | 2 | 0 | 0,41 | 0,42 |
| 5 | 0 | 0 | 2 | 2 |
| 6 | 2 | 3 | 1 | 0,15 |
| 7 | 0 | 0 | 0 | 2 |
Values of the |F| factor, recalculated using the formula. A zero indicates that the instrument is insensitive to that shape.
The table explains why no single workshop tool is sufficient on its own: the 60° prism, which is excellent for the three lobes, cannot detect either the oval or the five lobes; the micrometer cannot detect the odd-numbered lobes. In practice, you measure using the micrometer and two prisms with different angles (for example, 90° and 120°, or 60° and 90°) and take the worst result, knowing that it is an estimate. The true measurement requires an instrument that measures the radii.
A centerless-ground Ø25 pin with a roundness of 0.005 mm. When measured with a micrometer, it reads 25.000 in all directions. In the 60° prism, over one revolution, the dial indicator reads from −0.009 to +0.012 mm, with three peaks per revolution.
Another pin, roundness 0.008 mm. When measured with a micrometer, the diameters range from 39.992 to 40.004 mm, with two peaks per revolution. On the 60° prism, the dial indicator remains almost stationary; on the 90° prism, it moves 0.006 mm.
The Roundness Meter
The true tool for circularity is the rotundimeter: a rotating table mounted on a high-precision spindle (with a rotational error of just a few hundredths of a micrometer) and an electronic probe that traces the contour. The workpiece is centered and leveled on the table using the adjustment screws; any remaining eccentricity is corrected by the program. The result is a polar diagram: the contour drawn with deviations magnified thousands of times. The program fits a reference circle to it (usually the least-squares circle, or the minimum area circle, as required by the standard) and calculates circularity as the difference between the maximum and minimum radii measured from that center. A filter removes undulations that are too dense, which are attributable to roughness (Chapter 36): the number of waves per revolution of the filter must be recorded in the measurement report.
Required roundness: 0.006 mm. The roundness gauge, using a least-squares circle, yields a maximum deviation of +3.1 µm and a minimum deviation of −2.7 µm.
With such a small margin, measurement uncertainty comes into play: according to the rules of ISO 14253-1 discussed in Chapter 31, the workpiece is deemed compliant only if the value plus the uncertainty remains below the limit. With an uncertainty of ±0.3 µm, this workpiece would fall into the zone of doubt.
34.5 Cylindricity
Cylindricity requires that the entire surface lie between two coaxial cylinders with radii that differ by t. It encompasses, in a single value, the circularity of the cross-sections, the straightness of the generatrices, the taper, and the “barrel” of the workpiece. In the workshop, there is no simple method that truly measures it: a dial indicator mounted on a long prism, moved along the workpiece while it is rotated, provides a rough estimate that lumps everything together, with the same scaling issues seen for circularity.
The measurement is taken using a precision circular gauge with a vertical column, or with a CMM. The probe measures various sections at different dimensions and several generatrices along the column: the measurement lines form a sort of cage. The program calculates a common axis for all measurements and, relative to that axis, the difference between the maximum and minimum radii of the entire surface.
Pin with cylindricity 0,005. The roundness gauge measures three sections; the radius deviations from the common axis are, in µm: section 1 from −1.5 to +2.0; section 2 from −0.5 to +3.5; section 3 from −0.5 to +4.0.
34.6 Profile of a Line and a Surface
The profile checks any curve or surface (a cam, a fillet radius, a mold contour) against the theoretical shape, as defined by the theoretically exact dimensions or the 3D model. The zone is t wide and straddles the theoretical profile: ±t/2 on either side, unless otherwise specified in the drawing. The methods, from simplest to most comprehensive:
- template (jig): a ground metal sheet with the negative profile, placed against the workpiece and viewed against the light, with the thickness gauge inserted into the slots; two templates—one at the maximum limit and one at the minimum limit—form a “pass/fail” gauge for the profile;
- profile projector: projects the shadow of the workpiece, magnified 10, 20, or 50 times, onto a screen, on which a transparent template is mounted with the theoretical profile and the tolerance band drawn to the same scale; the shadow must lie entirely within the band. This method is suitable for small, thin workpieces: tool profiles, springs, small gears, and threads (Chapter 35);
- CMMs or scanning machines: They compare the measured points with the 3D model and highlight any deviations in color.
A profile with a tolerance 0,04 Check it using the projector with the 20× objective. At one point, the shadow extends beyond the theoretical outline by 0.5 mm, as measured on the screen.
34.7 Parallelism
Parallelism always has a reference. The surface is oriented parallel to the reference but can be at any height; for this reason, the dial indicator is used to measure the travel along the element, without regard to the absolute value. The travel also includes the shape errors of the element within tolerance, as required by the standard.
Between Two Flat Surfaces
The workpiece rests on the reference surface with reference face A; the surface simulates A. The dial indicator on its stand, with the base sliding along the surface, reads the upper face against a grid of points covering the entire surface, including the edges. Parallelism is the difference between the maximum and minimum readings. If face A is not perfectly flat, the workpiece wobbles: first check that it rests stably, and for delicate workpieces, support face A at three points (the reference is established based on the highest points).
Plate with 0.03 A on the top surface. Readings at eight points, in µm: +4, +8, +12, +6 on the first file; −2, −9, +3, 0 on the second.
Between a hole and a face
The axis of a hole is not touched directly: it is determined using a gauge pin, a ground cylinder that fits into the hole without any clearance (one can choose between pins that differ by 1 or 2 µm, or use an expandable pin). The pin protrudes on both sides, and the dial indicator measures its upper generatrix at two points, P1 and P2, as far apart as possible. The axis’s inclination is then related to the hole’s length, since the tolerance applies only there.
Ø20 H7 hole, 60 mm long, with a parallelism of 0.02 relative to base A (the area between two planes parallel to A). Pin Ø20 with no clearance; measurements on the pin: P1 = +0.008 mm, P2 = +0.033 mm, at Lm = 150 mm.
If the pin had clearance in the hole, it could rest at the bottom at one end and at the top at the other, and the reading would be skewed by the amount of clearance; this is why selecting the right pin is the most delicate part of the inspection.
Between Two Holes
When the reference is the axis of another hole, two pins are inserted: one in reference hole A and one in tolerance hole B. The workpiece is placed on the surface so that the two pins are horizontal, and it is adjusted using a jack or shims until pin A reads the same at both ends: now A is parallel to the surface, which becomes the reference. Then, read the measurement on pin B at both ends. If the area is cylindrical (Ø in the box), repeat the measurement with the workpiece rotated 90°, and combine the two results.
Hole B, which is 50 mm long, has a diameter of Ø0.01A, where A is the axis of the other hole. With pin A adjusted parallel to the plane, pin B reads B1 = +0.006 and B2 = +0.030 mm, at a distance of 200 mm. After rotating the workpiece 90° and readjusting, the difference between the two ends of B is 0.016 mm.
34.8 Perpendicularity
Perpendicularity is checked by comparing the workpiece to an object that is very precisely at 90°: a reference square or a square cylinder—a ground cylinder with bases perpendicular to the axis within a few micrometers. The cylinder is more convenient than the set square because it contacts the workpiece along a single generatrix and has no edges that need to be protected.
A face compared to the base
The simplest method is to use light: place the workpiece and the set square on the surface, with the set square against the face of the workpiece, and look at the gap against the light, just as you would with a ruler. To get numerical readings, use a dial indicator square: a column with a base that slides along the surface, a fixed button at the bottom, and a dial indicator at the top. First, place it against the cylinder of the square and zero it; then move it onto the workpiece, keeping the button in contact: the dial indicator reading is the deviation from the perpendicular over the distance between the button and the tip.
The face height is 100 mm with 0.03A, where A is the base. The dial caliper, with 80 mm between the button and the tip, zeroed on the caliper cylinder, reads +0.018 mm on the workpiece.
The measurement is valid if the surface is flat. If the workpiece has a curved surface, slide the dial indicator square to different heights, or measure the surface with a dial indicator that moves up a vertical precision column, and record the full range of movement.
The set square and the cylinder also have errors. An elegant way to eliminate this error is by flipping the set square: measure the workpiece with the set square on one side, then rotate the set square 180° and measure again on the other side of the workpiece; on average, the error in the set square cancels itself out.
A hole relative to a face
The workpiece rests on the surface with reference face A; a pin with no clearance is inserted into the hole so that it protrudes upward. A dial indicator, mounted on a vernier caliper or a height gauge, measures the side of the pin at two different heights. The procedure is repeated in the direction at 90°, and if the area is cylindrical, the two results are combined as in the case of parallelism between two holes.
30 mm deep hole with a tolerance of Ø0.01A. Measurements taken on the pin at a distance of 60 mm: difference of 0.015 mm in the X direction and 0.008 mm in the Y direction.
34.9 Inclination
Inclination is a form of parallelism “at an angle”: the face must lie between two tilted planes at the exact angle (shown in the box) relative to the reference. The cleanest way to check it is to reduce it to parallelism: place the workpiece on a sine plane (Chapter 33) that is tilted at exactly the theoretical angle, so that the face to be checked becomes horizontal, and measure it with the dial indicator just as you would any other face.
A 40-mm-long face, inclined at 30° (shown in the inset) relative to base A, has a thickness of 0.02A. The sine plane has a length of L = 100 mm. The comparator, along the line of maximum slope, ranges from 0 to +0.012 mm.
34.10 Location
Positional tolerance requires that the axis of a hole lie within a cylinder of diameter t centered at the exact theoretical position. Therefore, it is necessary to measure the coordinates of the axis relative to the reference points, calculate the deviations Δx and Δy from the exact dimensions, and compare the twice the distance with t (Chapter 15).
With the altimeter at the shop
The altimeter (digital level) measures heights above the reference plane. Insert a pin with no clearance into the hole, place the workpiece on the reference surface with the first reference face, and measure the height H of the pin; then rotate the workpiece 90°, placing it on the other reference face and aligning it with a square, and repeat the process. Each measurement yields a coordinate. If the hole is long, measure the pin near both faces of the workpiece, since the position is valid for the entire depth.
Drill with a Ø10 hole at x = 40 and y = 25 (exact dimensions, from A and from B) with Ø0,2AB. Pin Ø10,000 with no clearances. Face B on the plane: H = 30.068 mm. Face A on the plane: H = 44.952 mm.
Using the measuring machine
For workpieces with many holes, the altimeter is slow; a CMM is used instead. The machine probes the reference faces in the order shown in the diagram (A with three or more points, B with two, C with one), establishes the reference system, probes each hole in two sections, and calculates its axis. The report provides, for each hole, the deviations and the diameter of the occupied area.
Plate with 4 holes arranged in a square at the exact dimensions (20; 20), (80; 20), (80; 60), (20; 60) and Ø0,15ABC. The CMM finds the centers listed in the table.
| Forum | x measured | y measured | Δx | Δy | Actual Ø | Review |
|---|---|---|---|---|---|---|
| 1 | 20,031 | 19,962 | +0,031 | −0,038 | 0,098 | good |
| 2 | 80,058 | 20,044 | +0,058 | +0,044 | 0,146 | good |
| 3 | 79,940 | 60,071 | −0,060 | +0,071 | 0,186 | discard |
| 4 | 20,012 | 60,025 | +0,012 | +0,025 | 0,055 | good |
The functional gauge with the most material
When the box contains an “M,” the tolerance increases if the hole is wider than its minimum size (the “bonus” mentioned in Chapter 15). The check is performed in two ways: by measuring the diameter and position and calculating the allowable tolerance, or using a functional gauge—a plate with reference marks and pins that have the diameter of the virtual condition (minimum hole diameter minus the positional tolerance), at the exact dimensions. If the workpiece fits onto the pins without forcing, resting against the reference marks, the position is correct, including the bonus. The gauge does not check the diameter of the holes, which must be verified separately using a go/no-go plug gauge.
Two holes with a diameter of Ø8.5 +0.1/0 at exactly 260 mm, with a MAB of Ø0.2. On workpiece 1, one hole measures Ø8.56 with Δx = 0.09 and Δy = 0.10 mm; on workpiece 2, the same hole measures Ø8.58 with the same deviations.
34.11 Coaxiality and Concentricity
Coaxiality requires that the axis of the toleranced element lie within a cylinder of diameter t centered on the reference axis; concentricity is the same concept but applies to the center of a single section. The workshop method: The reference is simulated by resting pin A on two V-blocks (or by placing the workpiece between the centers, if A is the axis), with an axial stop against a ball to prevent the workpiece from sliding; rotate the workpiece one full revolution and use the dial indicator to measure the tolerance diameter in at least two sections, near its ends.
If the tolerance diameter is circular, the deflection in a section is equal to twice the eccentricity—that is, the diameter of the area containing the center of that section. But the deflection also includes the shape error (an oval diameter causes the pointer to move even if it is centered) and the shape error of pin A on the prisms. The method therefore overestimates coaxiality: if the value is within the tolerance, the workpiece is acceptable; if it is outside the tolerance, before rejecting it, it is measured with a roundness gauge or CMM, which distinguish between the center and the shape.
Small diameter with Ø0,03A. In one revolution, section 1 has a stroke of 0.018 mm, and section 2 has a stroke of 0.026 mm.
34.12 Symmetry
Symmetry requires that the median plane of a slot (or a stick-out) lie between two planes separated by a distance t, situated on either side of the reference plane or axis: the allowable displacement is ±t/2. The most common application in a machine shop is a keyway on a shaft, which must be symmetrical with respect to the axis so that the key engages on both sides.
The hole in a shaft
The shaft rests on a V-shaped prism (which simulates the A-axis). A test block (or a ground tab) is inserted into the slot; it fits without clearance and protrudes. Rotate the shaft until the slot is horizontal, as shown here: the top face of the block then aligns with one side of the slot. To ensure it is truly horizontal, slide the dial indicator along the block and rotate the shaft until the reading does not change. Take the reading, then rotate the shaft 180°, repeat the leveling process, and take the reading on the other side.
Bore diameter 12 with 0.05A, where A is the shaft axis. Initial reading +0.021 mm; after a 180° rotation, −0.015 mm.
The measurement is repeated at both ends of the groove: if the displacement changes, the groove is also skewed relative to the axis, and the worst value applies.
The groove on a prismatic workpiece
If the reference is the middle plane of a prismatic workpiece, place the workpiece on the plane with its first outer face and, using a dial indicator zeroed on a stack of blocks, measure the height of the side of the groove closest to the plane (distance a1); then place the workpiece on the opposite face and measure the other side (a2). The difference a1 − a2 is equal to 2e.
Block 80 mm wide with a 20 mm wide groove in the center, with a symmetry of 0.05 relative to the block’s median plane. The sides should be 30 mm from the outer faces: the dial indicator is zeroed on a stack of blocks 30.000 mm high. Readings: +0.04 mm on the first side (a1 = 30.04), −0.04 mm on the second (a2 = 29.96).
34.13 Circular and Total Runout
Runout is the tolerance “derived from the comparator”: the definition of the standard coincides with the inspection. The workpiece rotates around the reference axis (between the tailstocks, on V-blocks beneath the reference spindles, or on an expandable spindle between the centers if the reference is a hole), and the dial indicator, which remains stationary, reads the surface. Runout is the travel over one complete revolution.
- radial: a probe perpendicular to the axis, on the diameter; measurements are taken at multiple points, and the worst value is used. This includes eccentricity and circularity;
- axial: probe parallel to the axis, on the face, at the specified radius or near the edge; measurements are taken at multiple radii. It detects the inclination of the face, but not a symmetrical concave or convex face;
- Total: The workpiece rotates while the comparator moves along the entire diameter (total radial) or across the entire face (total axial), on a guide that is parallel or perpendicular to the reference axis; the deflection is read along the entire path. It also detects taper, barrel, and concave faces.
The procedure: Clean the centers of the workpiece and the tips (a single chip in a center can throw off the entire axis); mount the workpiece without axial clearance; position the dial indicator perpendicular to the surface with a slight preload; rotate the workpiece slowly at least one full revolution; and read the maximum and minimum values. A single rotation is not enough if you start near a maximum value: perform two rotations and verify that the values repeat.
Diameter at 0.02 A. Workpiece between the tips, readings every 45°, in µm: 0, +6, +11, +13, +9, +3, −2, −3.
The bushing shown in Figure 34.21 has an axial runout of 0.02 on the flange face and a total runout of 0.03A on the outer diameter. The axial dial indicator, at a radius of 40 mm, has a travel of 0.014 mm. The radial dial indicator, moved along its entire length during rotation, reads a maximum of +0.019 mm and a minimum of −0.008 mm.
34.14 Common Assembly Errors
Almost all errors in geometric inspection are caused not by the instrument but by the setup. Here are the most common ones, along with their solutions.
- Incorrect reference: The workpiece is placed on the most convenient surface instead of the one indicated by the letter. A shaft with a reference on pin A, placed on the prisms under a different diameter or between the centers when the reference is not the centers, causes runout that does not match the drawing. Solution: Reread the box, identify the letter on the drawing, and simulate that exact surface in the primary, secondary, and tertiary order;
- Dial indicator tip not perpendicular: when the rod is tilted by an angle α, the reading is too high (cosine error, Chapter 31); with a lever-type dial indicator, the arm must be nearly parallel to the surface. Solution: Align the rod with the direction of measurement or correct the reading by multiplying it by cos α;
- Dirt, chips, and burrs: A chip under the workpiece or in the center causes the entire measurement to be skewed; a burr on the edge causes the burr to be detected. Solution: Clean the table, workpieces, prisms, and centers before each measurement, and deburr;
- The mount gives way: the arm is too long, the joint is not tightened, or the magnetic base is not properly secured. The pointer moves if the mount is touched. Solution: use a shorter arm, tighten the joints, and check repeatability by re-reading the same point;
- pins and spindles with clearances: the clearances add to the measured value. Solution: select pins without clearances, use expandable spindles, and check by rotating the pin in the hole;
- Temperature: A workpiece that has just been worked on or held in the hand expands unevenly. Solution: Let it stabilize on the work surface (Chapter 31);
- A few data points: with only a few readings, the error is lost. Solution: dense grids, complete revolutions, continuous rotation instead of step-by-step rotation.
A radial runout with a tolerance of 0.022 mm is measured using a dial indicator whose arm forms a 30° angle with the surface. The pointer has a travel of 0.024 mm.
34.15 Summary Table and Formulas
| Tolerance | Tools | Assembly | What's in the news |
|---|---|---|---|
| straightness | knife-edge ruler and thickness gauge, dial indicator, autocollimator | workpiece on two identical blocks, a comparator that slides along the line | excursion after deducting the fee for the details |
| flatness | comparator, optical glass, electronic level | workpiece supported by three jacks positioned at three points; grid | grid span (upper limit); fringes · 0.3 µm |
| circularity | roundness gauge; micrometer and prisms for estimation | workpiece centered on the board; or on prisms with two corners | difference in radii; on the prism, excursion / F |
| cylindricity | Column-mounted roundness gauge, CMM | more sections and generators | difference in radii relative to the common axis |
| profile | contour profiles, profile projector, CMM | workpiece on the projector table, scale mask | deviation from the theoretical profile within ±t/2 |
| parallelism | mountable comparator, pins | reference on the plane or A-pin adjusted to be parallel | displacement, normalized to length; Ø = √(fx² + fy²) |
| perpendicularity | square, cylindrical square, dial indicator square, pins | workpiece on the surface with the reference mark; vertical pin in the hole | offset based on the instrument, adjusted to the height |
| tilt | flat surface and blocks, dial indicator | blocks H = L · sin α, with one face horizontal | hike along the steepest slope |
| position | altimeter and plugs, CMM, gage blocks | workpiece on the reference faces, rotated 90° | Δx, Δy → 2 · √(Δx² + Δy²) ≤ t (plus the bonus with the M) |
| coaxiality and concentricity | comparators, roundness gauge, CMM | Pivot A on two prisms or a workpiece between the centers | multi-section hike = 2e (upper limit) |
| symmetry | control block, comparator, blocks | shaft on a prism, horizontal slot, 180° rotation | Δ = 2e; this is acceptable if Δ ≤ t |
| circular runout | comparator, tailstocks, prisms, expandable spindle | workpiece rotating around the reference point, with the comparator stationary | excursion in a loop, in each section or radius |
| total runout | as above, with a guide for the comparator | The comparator moves as it rotates | full-surface excursion |
| What Are You Looking For? | Formula | Units |
|---|---|---|
| Deviation from the line for the endpoints | si = li − l0 − (ln − l0) · xi / L | µm |
| Flatness of Optical Glass | N · λ / 2 ≈ N · 0,3 | µm |
| V-prism factor | F = 1 + (−1)^n · cos(n · γ) / cos γ, where γ = 90° − β/2 | number |
| Circularity from the Prism | Δr = displacement / |F| | mm |
| Restore to the allowed length | f = Δ · L / Lm | mm |
| Cylindrical zone from two directions | Ø = √(fx² + fy²) | mm |
| Sine-wave blocks | H = L · sin α | mm |
| Coordinated by the altimeter | y = H − d / 2 | mm |
| Location Verification | Øreal = 2 · √(Δx² + Δy²) ≤ t | mm |
| Permissible tolerance with M (hole) | t + (Deff − DMMC) | mm |
| Functional gauge pin (hole) | DMMC − t | mm |
| Eccentricity and Coaxiality | e = stroke / 2 · Ø = 2 · emax | mm |
| Symmetry with a 180° rotation | Δ = l1 − l2 = 2e; this is acceptable if Δ ≤ t | mm |
| Cosine Error | true value = reading · cos α | mm |
34.16 Exercises
Before doing any calculations, ask yourself: Should the excursion be considered as a whole, halved, divided by a factor, or converted to a different length?
Solution
The straight line between the endpoints rises by 2 µm over 400 mm, or 0.5 µm per 100 mm. Deviations: 0; 5 − 0.5 = 4.5; 8 − 1 = 7; 7 − 1.5 = 5.5; 2 − 2 = 0 µm. Straightness = 7 − 0 = 7 µm = 0.007 mm ≤ 0.008: good (the blank deviation, 8 µm, would have been at the limit).
Solution
Relative to the three-point plane, the displacement is 6 − (−5) = 11 µm, which exceeds the tolerance. But this is only an upper limit: we cannot rule it out immediately. By calculating the minimum area based on the same readings (with the tilted plane as much as possible), we obtain approximately 6.3 µm ≤ 10: the plate is acceptable.
Solution
5 · 0.29 = 1.45 µm > 1 µm: out of tolerance (must be re-lapped).
Solution
For five lobes, the 90° prism has F = 2: Δr = 0.012 / 2 = 0.006 mm. The micrometer (F = 0 for the odd-numbered lobes) and the 60° prism (F = 0 for five lobes) would not detect anything: both would indicate “round.”
Solution
Two maxima, a sensitive micrometer, and a 60° blind prism: it is an oval. From the micrometer, Δr = 0.010 / 2 = 0.005 mm; from the 90° prism (F = 1), Δr = 0.005 mm. Circularity: 0.005 mm.
Solution
f = 0.03 × 45 / 120 = 0.01125 mm > 0.01: out of tolerance by just over one micrometer (it is advisable to repeat the measurement and check the pin’s clearance).
Solution
fx = 0.010 × 60 / 150 = 0.004 mm; fy = 0.018 × 60 / 150 = 0.0072 mm. Ø = √(0.004² + 0.0072²) = √(0.000016 + 0.00005184) = √0.00006784 = 0.0082 mm ≤ 0.01: good.
Solution
f = 0.020 × 120 / 100 = 0.024 mm ≤ 0.025: good, but with a margin of only one micrometer. With a measurement uncertainty of a few micrometers, the result falls into the “doubtful” zone defined by ISO 14253-1 (Chapter 31): it is advisable to remeasure the surface at multiple heights or using a CMM.
Solution
H = 200 · sin 15° = 200 · 0.25882 = 51.764 mm. The travel is 0.015 mm ≤ 0.02: acceptable.
Solution
y = 37.946 − 6 = 31.946 → Δy = −0.054 mm; x = 21.035 − 6 = 15.035 → Δx = +0.035 mm. Actual diameter = 2 · √(0.035² + 0.054²) = 2 · √(0.001225 + 0.002916) = 2 · √0.004141 = 2 · 0.0644 = 0.129 mm ≤ 0.15: good.
Solution
Actual diameter = 2 · √(0.0049 + 0.0081) = 2 · √0.013 = 2 · 0.1140 = 0.228 mm. Tolerance: 0.15 + (6.64 − 6.60) = 0.19 mm. 0.228 > 0.19: out of tolerance. Gauge pin: 6.60 − 0.15 = 6.45 mm; clearance in the hole: 6.64 − 0.228 = 6.412 mm < 6.45, so the pin does not fit: same result.
Solution
Δ = 25.02 − 24.97 = 0.05 mm = 2e → e = 0.025 mm. Tolerance ±0.02: 0.05 > 0.04, rejected.
Solution
Radial: 12 − (−2) = 14 µm ≤ 15, acceptable (eccentricity approximately 7 µm). Axial: 0.022 > 0.02, reject. The workpiece is rejected due to the face.
Solution
The value from the comparator is 0.034 mm > 0.03, but the tolerance also accounts for shape errors in the diameter and pin A: this is an upper limit. It is not immediately rejected: the workpiece must be remeasured using a roundness gauge or a CMM, which calculate the centers of the cross-sections. If the coaxiality exceeds 0.03 there as well, then it is rejected.