Chapter 33

Angles and Cones

An angle that’s off by just a few prism units isn’t visible to the naked eye, but you can feel it: a guide that doesn’t slide smoothly, a Morse taper that wobbles in the tube, a workpiece that doesn’t fit together with another. In this chapter, we review all the tools used in the workshop and metrology lab to check angles and cones, from the set square held up to the light to the autocollimator that measures to a tenth of a second. For each instrument, we’ll examine its design, how to read it, and how to set it up, with new numerical examples. The calculations for cones, sine bars, and rollers are already covered in Chapter 6; here, we’ll refer back to them and use them for measurements.

33.1 Angles in the Workshop: Units and Orders of Magnitude

Angles are measured in sexagesimal degrees: A full circle is 360°, a degree is 60 primes (60′), and a prime is 60 seconds (60″). Drawings and numerical calculations often use decimal degrees (12.5° instead of 12°30′), while trigonometric formulas work in radiant. The conversions are explained in section 2.10; here, it is especially important to understand How big is it? a small angle, because in metrology, angular errors are almost always expressed in primes and seconds.

The most practical way is to think of a small angle as a slope: how many millimeters you climb per meter of length. For small angles, tan θ ≈ θ (in radians), so the elevation gain is simply length times the angle.

Small angles such as slopes
e = L · tan θ ≈ L · θrad θrad = θ″ · π180 · 3600 = θ″ · 4,848 · 10−6
1′ ≈ 0.29 mm per 1 m 1″ ≈ 4.85 µm per 1 m 1 mm/m ≈ 3′26″
and deviation (height difference, out-of-square) in mm · L length over which it is measured in mm · θ angle; θrad in radians, θ″ in arcseconds. The approximation tan θ ≈ θ is accurate to within one part per thousand up to about 3°.
Example 33.1 · From Angles to Millimeters and Back

A tilted plane is at an angle of 0°12′ relative to the horizontal. How much does it rise over a distance of 400 mm? And a surface that is out of square by 0.3 mm over a distance of 500 mm—by what angle is it out of square?

0°12′ = 12/60 = 0.2° → tan 0.2° = 0.0034907
e = 400 × 0.0034907 = 1.396 mm
Second case: θ = arctan(0.3 / 500) = arctan 0.0006 = 0.034377° = 0°2′4″
Quick check using the rule: 0.3 mm over 500 mm = 0.6 mm/m; 0.6 / 0.29 = 2.07′ ≈ 2′4″ ✓
1.40 mm over 400 mm · squareness error of approximately 2′
ToolTypical resolutionUsage
Simple Protractor1°tracking, rough checks
Universal protractor with vernier scale5′any corner of the workshop
Digital Protractor0,01°-0,05° (36″-3′)workshop, assembly
Precision Spirit Level0.02 mm/m (≈ 4″)bubble-wrapped, pallets
C-frame with blocks and dial indicatora few secondsAngle and Cone Inspection
Electronic level0.001–0.01 mm/m (0.2″–2″)machine geometry
Autocollimator0,1″-1″straight lines, dividers, polygons

These are approximate values, which vary by manufacturer.

33.2 Squaring and Checking Perpendicularity

The angle that is checked most often is the right angle. The set square is the physical embodiment of 90°: a workpiece of hardened and ground steel (or granite) with two faces that are perpendicular to each other within a few micrometers. There are three main types.

  • Flat square: a thick L-shaped sheet of metal with the edges of both arms ground smooth. It is used for marking and visual inspections.
  • Team in a Hat (or base-mounted): a thin blade attached to a thick base. The base rests securely on the reference surface or against one side of the workpiece, while the blade checks the other side. It is the quintessential workshop square; the best ones have a blade with chamfers (like a knife) to better catch the light.
  • Square cylinder: a ground cylinder with bases perpendicular to its axis. When placed on a flat surface, its outer surface forms a perfect vertical line that touches the workpiece along a single generatrix; this makes it very easy to read the clearance. It is also used as a reference for calibrating other squares.
90°flat right angleground sheet metal, edgesbladethick base (cap)hat-style squarestands upright on a flat surfaceside⟂ basecylinder squaretouches along a single line
Figure 33.1 · The three teams. The “hat” team and the “top hat” team stand on their own on the reference plane, leaving their hands free.

The light-slit test

Place the base of the set square on the surface (or on the reference face of the workpiece), gently bring the blade close to the face to be inspected, and look at it against the light, with a bright background behind it. If the surfaces are perpendicular, no light passes through; if not, a wedge of light is visible, starting at zero on one side and widening toward the other. A trained eye, under good lighting, can detect gaps of 2–3 µm. To estimate the width, compare the gap to a reference gap: place two blocks of different thicknesses (for example, 10.000 and 10.005 mm) on the surface, rest a ruler on top, and the gap between the ruler and the lower block is 5 µm wide.

backlightreference planesquareworkpiecefwedge-shaped lightthe eye looks toward the lighthAt the top, the light iswide f at the top, zero at the bottom
Figure 33.2 · The hat-shaped square placed against the workpiece, viewed against the light. The surface of the workpiece is inclined (greatly exaggerated): the light passes through in a wedge shape, with a width f at the top and none at the bottom.
Perpendicularity Error from the Slot
θrad ≈ fh error in mm/m = fh · 1000
f: maximum crack width in mm · h: distance between the contact point and the point of maximum crack width, in mm · θ: angular error relative to 90°
Example 33.2 · Out-of-square shoulder joint

A milled plate is placed on the surface and checked with a hat-shaped square. The blade touches at the bottom and top; at a height of 120 mm, the gap is estimated to be 0.015 mm (between the 10- and 20-µm reference gaps). How out of square is the face?

θ = 0.015 / 120 = 0.000125 rad
in seconds: 0.000125 / 4.848 × 10−6 = 25,8″ ≈ 26″
as slope: 0.000125 × 1000 = 0.125 mm/m
Error of approximately 26″ (0.125 mm/m); if the drawing specifies a perpendicularity tolerance of 0.02 mm on that face (Chapter 15), the plate is acceptable

When a precise measurement is needed rather than an estimate, a comparator mounted on a column or on a carriage that slides along the table is used instead of the blade: it is zeroed at the bottom against the square cylinder, the reading is taken at the top, and then the same procedure is repeated on the workpiece. The difference between the two readings, divided by the height, gives the perpendicularity error. The actual inspection of perpendicularity tolerances is covered in Chapter 34.

33.3 Simple Protractors and Universal Protractors with a Vernier Scale

The simple protractor A workshop protractor is a semicircular sector graduated in degrees, with a support base and a swiveling arm with a pointer. It is used for marking and checking where a degree of uncertainty is sufficient, such as the angle of a bent sheet of metal or a weld bead. Be careful which angle you read: the instrument measures the angle between the base and the arm, which may be the complementary angle (180° minus) of the angle you are interested in.

030609012015018052°arm with indexsupport basedegree-marked sector145°The bed angle is the angle between the base and the arm:the chamfer is inclined at 180° − 145° = 35°
Figure 33.3 · On the left is a simple protractor with the arm at 52°. On the right is the same concept applied to a workpiece: the base rests on the top face, and the arm rests on the chamfer. The reading is 145°, and the angle of the chamfer relative to the face is 35°.

The universal goniometer (also known as a bevel protractor) is a workshop tool for measuring any angle. It consists of a base, a fixed dial graduated in degrees from 0 to 90 and back (0-90-0-90), and a rotating disc that holds the vernier scale and the blade, which slides and locks into place at any stick-out. A locking ring blocks the disk, and a magnifying lens enlarges the vernier scale; many models include an accessory for measuring acute angles. The resolution is 5 primes.

αsliding bladelens on the vernier scalefixed dialscaled 0-90-0-90rotating discwith vernier scalelocking ringBase (fixed body): rests on one side of the workpiece
Figure 33.4 · The universal goniometer. The angle α being measured is the angle between the base and the arm; the disc with the vernier scale rotates along with the arm in front of the fixed dial.

The 5′ vernier scale

The angular vernier works like the one on a caliper (Chapter 32), but with degrees instead of millimeters. On the rotating disc, on either side of zero, there are 12 divisions that cover a total of 23° of the main scale. Each division of the vernier scale is therefore 23°/12 = 1°55′, or 5′ less than two degrees. When the zero mark on the vernier is aligned with a whole degree, vernier line 1 is 5′ before the second degree, vernier line 2 is 10′ before the fourth, and so on. If you rotate the disk by 5′, line 1 aligns; by 10′, line 2 aligns; and by 55′, line 11 aligns.

Angular Vernier Resolution
a = 2 · p − 23 · p12 = p12 = 60′12 = 5′
reading = whole degrees before the zero mark on the vernier scale + (number of the corresponding line) × 5′
a resolution (value of a vernier scale line) · p Value of one division on the main scale; here, 1° = 60′. The vernier scale lines are numbered in prime: 0, 15, 30, 45, 60 every three lines.
Vernier at zero: reading 0°00′0°5°10°15°20°25°0′15′30′45′60′There is a 5′ gap between the 1st mark on the vernier scale (1°55′) and the 2nd mark on the scaleVernier scale rotated by 5′: the 5′ line coincides0°5°10°15°20°25°0′15′30′45′60′coincidence: reading 0°05′
Figure 33.5 · The two scales laid out in a plane (they are actually arcs of a circle). Above the vernier, the scale is set to zero: only the zero mark and the 60′ line coincide with 23°. Below, the disc is rotated by 5′: the 5′ line (in red) coincides with 2°.

There are three rules for reading.

  • Read the whole degrees on the main scale, up to the zero mark on the vernier scale, in ascending numerical order;
  • Find the vernier scale line that coincides with a line on the scale, on the same side as the degrees increase: the number on that line gives the prime numbers;
  • On the other half of the vernier scale, there is always a second alignment (that of 60′ minus the first exact value): this should not be taken into account.
1001020304060453015015304560main scale in degrees (top) · vernier scale in primes (bottom)
Figure 33.6 · Example 33.3: The vernier zero (red) is just past 12°; on the right, it coincides with the 25′ line (red). The coincidence on the left, at the 35′ line, belongs to the other half and does not count.
Example 33.3 · First reading of the vernier scale

Read the protractor in Figure 33.6, where the degrees increase to the right.

The vernier scale zero is between 12° and 13° → whole degrees: 12°
To the right of zero, the fifth line—the one between 15 and 30 that is closest to 30—coincides with it: 5 × 5′ = 25′
Verification: Line 5 is 5 · 1°55′ = 9°35′ from zero; 12°25′ + 9°35′ = 22°00′, a full degree ✓
Reading: 12°25′
20304050607060453015015304560main scale in degrees (top) · vernier scale in primes (bottom)
Figure 33.7 · Example 33.4: The vernier zero is between 47° and 48°, coinciding with the 40′ line.
Example 33.4 · Reading and Workpiece Angle

The protractor shown in Figure 33.7 is mounted with its base on one face of a support and its blade on the inclined side. What angle does it read? If the drawing provides dimensions for the obtuse angle between the two faces, what is its measure?

degrees before zero: 47°
alignment on the right: eighth line, 8 × 5′ = 40′
Check: 8 · 1°55′ = 15°20′; 47°40′ + 15°20′ = 63°00′ ✓
obtuse angle: 180° − 47°40′ = 179°60′ − 47°40′ = 132°20′
Reading 47°40′; obtuse angle between the faces 132°20′

33.4 Digital Levels, Inclinometers, and Goniometers

A spirit level does not measure the angle between two surfaces, but rather the inclination of a surface relative to the horizontal—that is, relative to gravity. Inside the vial—a glass tube curved with a very large radius and filled with liquid—the air bubble always rises to the highest point. The graduations on the vial are usually spaced 2 mm apart.

The sensitivity of a spirit level is the angle of inclination that causes the bubble to move by one division. It is expressed in mm/m: “0.02 mm/m” means that if the bubble moves by one division, the surface rises by 0.02 mm per meter. Mechanics’ levels have a sensitivity of 0.02 or 0.05 mm/m, while fitters’ levels have a sensitivity of 0.1 mm/m or higher. The more gently curved the vial is (larger radius), the more sensitive the level is.

steel bodyV-shaped prismatic basemain vialbase length 150–300 mmzero bubble between the central sections3 divisions1 division = 2 mm on the vialsensitivity 0.02 mm/m ≈ 4″Inner radius of the vial ≈ 100 m
Figure 33.8 · Bench level with a V-shaped base (which can also rest on shafts). In the enlarged view, the bubble has shifted 3 divisions to the right: the right side of the level is higher.
Reading the level
i = n · S e = i · L R = pS/1000
0.02 mm/m ≈ 4.1″ 0.05 mm/m ≈ 10.3″ 0.1 mm/m ≈ 20.6″
i: inclination in mm/m · n: bubble displacement in divisions · S: sensitivity in mm/m per division · e: elevation difference in mm · L: length in m · R: radius of curvature of the vial in mm · p: scale interval on the vial in mm
Example 33.5 · The bubble shifted by three divisions

A level with a sensitivity of 0.02 mm/m, placed on a 1.6-meter-long bench, shows the bubble shifted 3 divisions to the right (Figure 33.8). How much is the bench inclined? How much higher is the right end? What is the radius of the vial, with 2-mm graduations?

i = 3 × 0.02 = 0.06 mm/m
in seconds: 3 · 4.125″ = 12.4″
e = 0.06 × 1.6 = 0.096 mm
radius of the vernier scale: 0.02 mm/m = 0.00002 rad per division → R = 2 / 0.00002 = 100,000 mm = 100 m
Slope: 0.06 mm/m (approximately 12″); the right side is 0.10 mm higher; the vial has a radius of 100 m

The Inversion Method

No spirit level has a perfect zero reading. To avoid relying on its error, take two readings: one normally and one after rotating the level 180° at the same point, marking the positions of the ends with a pencil. The spirit level’s error does not change sign, but the surface’s inclination does: the half-difference of the readings is the true inclination, and the half-sum is the spirit level’s error (which can be corrected using its adjustment screw).

Example 33.6 · Spirit level with an offset zero mark

Using a spirit level with a sensitivity of 0.02 mm/m, the reading is +2 divisions (bubble to the right). When rotated 180° at the same point, the reading is −0.5 divisions (bubble to the left, still viewed from the same side). What is the angle of the surface?

true inclination = (+2 − (−0.5)) / 2 = 2.5 / 2 = 1.25 divisions
level error = (+2 + (−0.5)) / 2 = 0.75 divisions
1.25 × 0.02 = 0.025 mm/m
The surface has a slope of 0.025 mm/m; the level alone would have indicated 0.04 mm/m

Electronic levels, inclinometers, and digital protractors

An electronic level replaces the bubble with a pendulum or a capacitive sensor and displays the inclination on a screen, in mm/m or in seconds. The best models have a resolution of 0.001 mm/m (approximately 0.2″) and can operate in differential mode: two probes, one on the fixed part and one on the part being checked, and the instrument displays the difference, thereby canceling out floor vibrations. They are the standard tool for geometric testing of machine tools.

The digital inclinometers shop-calibrated (resolution 0.05° or 0.1°) and the digital protractors These two-arm instruments, featuring an encoder in the pivot (resolution 0.01°), are convenient for surveying: they can be zeroed on any surface (ZERO button) and measure the relative angle, or they can measure relative to the horizontal (ABS mode).

32.05°Digital protractor: encoder in the pivot,resolution 0.01° or 0.05°, ZERO/ABS button+0.037 mm/mpendulumElectronic level (precision inclinometer):resolution up to 0.001 mm/m (approx. 0.2″),absolute or differential measurement between two probes
Figure 33.9 · On the left is the digital goniometer: the angle between the two arms appears on the display. On the right is the electronic level: a pendulum (or a capacitive sensor) measures the inclination relative to gravity.
Example 33.7 · The electronic level on the table

The table of a 800-mm-long milling machine is checked with an electronic level, which reads +0.037 mm/m. What is the slope in seconds, and how much does the table rise from one end to the other? What reading would be shown on a digital protractor with a resolution of 0.05°?

0.037 mm/m = 0.000037 rad → 0.000037 / 4.848 × 10−6 = 7,6″
e = 0.037 × 0.8 = 0.0296 mm ≈ 0.030 mm
0.05° = 180″: the inclination is 7.6 / 180 = 0.04 of the resolution
7.6″, or 0.03 mm out of 800 mm; a digital protractor would read 0.00°: for machine geometry, you need a level

33.5 Combination Square and Fixed Angle Gauges

The combination tool is a graduated steel rail with a groove, on which three different heads slide and lock into place:

  • a square, with one face at 90° and one at 45°, and often a small level: used for marking lines, checking 45° chamfers and bevels, and measuring depth;
  • the goniometric head, a simple protractor with a spirit level that locks at the desired angle;
  • The V-shaped center-finding tool: when placed on a shaft, the line passes exactly through the center and allows you to mark it on the face.
ruler with a central notchsquare head:90° and 45° faces45°90°protractor head with spirit level(rotates and blocks at the desired angle)Center-finding head: the ruler passes through the centerof a shaft resting in the V-groove
Figure 33.10 · The combination set square: a ruler and three interchangeable heads. It is a marking tool with an accuracy of a few tenths of a degree.

When you need to check the same angle on multiple workpieces, it’s not practical to measure it each time: instead, use a fixed gauge (template)—that is, a steel strip with the correct angle cut into the edge. Place it against the workpiece and check the gap, just as you would with a set square. The most common ones are:

  • V-shaped or edge profiles at 30°, 45°, 60°, 90°, and 120°, often grouped together in a bundle;
  • The tap sharpening gauge: It has a flank angle of 59° from the axis (half of the 118° of a standard tap) and a scale to check that the two cutting edges are the same length. A drill bit with unequal cutting edges produces a hole larger than its diameter (Chapter 28);
  • the “fishtail” gauge for threading tools: it has 60° grooves (metric threads) or 55° grooves (Whitworth) and is used both to sharpen the tool and to position it perpendicular to the workpiece on the lathe;
  • comb-type thread gauges, which check the pitch and angle of the thread by comparison (Chapter 35).
30°45°60°V-shaped templates for fixed angles(check for light between the template and the workpiece)Gauge for sharpening drill bits:flank at 59° from the axis (118° total),scale for the two identical cutting edgespoint60°"fishtail""fishtail" gauge forthreading tools
Figure 33.11 · Fixed-angle gauges: 30°, 45°, and 60° V-shaped gauges, the 118° tip-sharpening gauge, and the fishtail gauge for 60° threading tools.
🔧
Fixed gauge or measurement? The template only indicates “good” or “needs redoing,” and with a light, you can see differences of a few firsts on the long sides, much less so on the short sides. If you need to know exactly how much of a deviation there is, switch to a protractor or a sine bar.

33.6 The sine bar and the sine plane

The sine-bar theory is described in Section 6.12: two rollers separated by a distance L, a stack of blocks of height H beneath one roller, and the bar is inclined at an angle such that sin α = H/L. Here we see how it is actually used to check an angle, which is the most common application in the metrology lab. The sine plane is essentially the same concept on a larger scale: a plane with rollers and a hinged base, on which the workpiece is secured with clamps or a magnet; it is also used in grinding to achieve precise angles.

The Step-by-Step Procedure

  • Clean the table, bar, blocks, and workpiece; keep everything at the same temperature (paragraph 31.10);
  • Calculate H = L · sin α using the nominal angle of the workpiece, and assemble the stack of blocks (see method below);
  • Place the bar so that one roller rests on the work surface and the other on the stack; place the workpiece on the bar against the stop so that the surface to be inspected is horizontal;
  • Place the comparator on its stand above the surface, at the beginning of the area to be checked, and zero it (or note the reading);
  • Slide the support along the surface to the other end, at a distance l, and read the difference Δ;
  • If Δ = 0, the angle is the nominal angle; otherwise, the error is Δ / l in radians. If the end closest to the blocks is higher, the angle of the workpiece is greater than the nominal angle.
reference planeworkpiecetravel l = 60 mmcomparatorL = 100Hblocks 25 + 11 + 1.26 + 1.008αstop
Figure 33.12 · Checking an angle of 22°30′ on the 100-mm sine bar. With the correct stack, the top surface of the workpiece should be horizontal: the dial indicator, moved a distance of l = 60 mm, reads the deviation.

Choosing the blocks

A standard set of flat-parallel blocks consists of 112 workpieces: 1.0005 mm; from 1.001 to 1.009 in increments of 0.001; from 1.01 to 1.49 in increments of 0.01; from 0.5 to 24.5 in increments of 0.5; and the large ones at 25, 50, 75, and 100 mm. The stack is assembled starting from the last decimal place and using as few blocks as possible, because each block adds its own error and a slight gap between the faces. The blocks are joined by friction (they are slid over one another until they “stick” together), after they have been cleaned.

Example 33.8 · Checking an angle of 22°30′

A support has a face inclined at 22°30′ with a tolerance of ±2′. Check it on a 100-mm sine bar. The dial indicator, moved 60 mm along the surface, reads +0.018 mm at the end nearest the blocks. Assemble the stack and determine whether the workpiece is acceptable.

22°30′ = 22.5° → sin 22.5° = 0.382683
H = 100 × 0.382683 = 38.268 mm
thousandths: 1.008 → leaves 37.260; hundredths: 1.26 → leaves 36.000; then 11 and 25
Check: 1.008 + 1.26 + 11 + 25 = 38.268 mm ✓ (four blocks)
error: 0.018 / 60 = 0.0003 rad = 0.0003 / 4.848 × 10−6 = 61,9″ ≈ 1′02″
the end closest to the blocks is higher → the angle is larger: 22°30′ + 1′02″ = 22°31′02″
Stack 1.008 + 1.26 + 11 + 25; measured angle 22°31′, within ±2′: workpiece is good
Example 33.9 · The 200-mm sine plane

On a sine plane with L = 200 mm, the face of a mold inclined at 7°15′ must be checked. What stack is needed?

7°15′ = 7.25° → sin 7.25° = 0.126199
H = 200 × 0.126199 = 25.240 mm
thousandths: 0 → no 1.00x blocks; hundredths: 1.24 → remains 24.000; then 24
Check: 1.24 + 24 = 25.24 mm ✓
Two blocks are enough: 1.24 + 24 = 25.240 mm

The sine bar is accurate for small and medium angles; near 90°, the sine changes very little, and every micrometer on the blocks results in a large angular error (paragraph 33.14). For angles greater than 45°, rotate the workpiece 90° and measure the complementary angle.

33.7 Measuring an external cone with two rollers and blocks

A cone can be checked on a sine bar (examples 6.18 and 6.19), but there is a method that requires only a micrometer, two identical rollers, and two stacks of identical blocks. The cone is placed on the reference surface with its larger base facing down; the two rollers are positioned on the surface in contact with the cone, on opposite sides, and the dimension M₁ above the rollers is measured with the micrometer. Then the rollers are raised onto two stacks of blocks of height H, and M₂ is measured.

As H increases, the dimension above the rollers decreases by an amount equal to the decrease in the cone’s diameter, that is, 2 · H · tan(α/2): the diameter of the rollers and their position no longer matter. The base diameter can also be derived from the first dimension, using the same principle as for a dovetail joint (Section 6.10): the roller lies in the angle between the plane and the generatrix, which here is 90° + α/2.

M₁rollers resting on the surfaceM₂Hrollers stacked in two equal piles H
Figure 33.13 · The cone from Example 33.10 to scale: on the left, the Ø12 rollers resting on the surface (dimension M₁); on the right, the same rollers raised on two 30-mm-high stacks (dimension M₂, which is smaller).
Outer cone with two rollers
tan α2 = M1 − M22 · H D = M1 − dr · (1 + cot(45° + α4))
M1: dimension above the rollers resting on the surface, in mm · M2: dimension above the rollers raised on the stacks · H: height of the block stacks, in mm · α: cone opening angle (α/2 is the half-angle) · D: base diameter of the cone, in mm · dr: diameter of the rollers, in mm. The term 45° + α/4 is half of the angle 90° + α/2 between the plane and the generatrix.
Example 33.10 · A 14° cone with 12 rollers

A conical pin has a base diameter D = 50 mm and an angle α = 14° (α/2 = 7°). When measured with 12-mm rollers and 30-mm stacks, the results are: M₁ = 72.640 mm and M₂ = 65.254 mm. What was expected? What is the angle of the workpiece, and what is the base diameter?

Calculations: cot(45° + 3.5°) = cot 48.5° = 0.88473 → M1 = 50 + 12 × 1.88473 = 72.617 mm
M1 − M2 = 2 × 30 × tan 7° = 60 × 0.122785 = 7.367 mm → M2 = 65.250 mm
workpiece: tan(α/2) = (72.640 − 65.254) / (2 × 30) = 7.386 / 60 = 0.12310
α/2 = arctan 0.12310 = 7.0178° = 7°1′4″, which is 1′04″ more than shown in the drawing
base diameter: cot(45° + 7.0178°/2) = cot 48.5089° = 0.88445 → D = 72.640 − 12 · 1.88445 = 72.640 − 22.613 = 50.027 mm
α/2 = 7°1′04″ (α = 14°2′08″) · D = 50.027 mm
💡
Why two dimensions? With just one dimension, you would have an equation with two unknowns: the angle and the diameter. The difference between M₁ and M₂ eliminates the diameter and gives the angle; then, once the angle is known, M₁ gives the diameter. The two stacks must be identical to the micrometer: they are assembled using the same nominal blocks and checked with a comparator on the table.

33.8 Measuring an Internal Cone Using Two Spheres

A micrometer won’t fit inside a conical hole, but a calibrated sphere will. The sphere stops where the hole’s diameter is just right for it, and its depth can be easily measured from the surface of the workpiece using a depth micrometer (or a dial indicator mounted on a bridge zeroed to the plane). Using two spheres of different diameters yields two depths, and the triangle formed by the two centers gives the angle.

h₁Ø28small sphereh₂Ø36large spherecross-section of the inner cone 7:24 (to scale); h is measured with a depth micrometer resting on the face
Figure 33.14 · The 7:24 seating of a 40-series spindle (mouth diameter 44.45 mm) with a 28-mm ball and a 36-mm ball. h₁ and h₂ are the depths from the top of the balls to the face.

The center of a sphere of radius R resting inside a cone lies on the axis, at a distance of R / sin(α/2) from the vertex. The difference in depth between the two centers, (h₁ + R₁) − (h₂ + R₂), is therefore (R₂ − R₁) / sin(α/2).

Inner cone with two balls
sin α2 = R2 − R1(h1 − h2) + (R1 − R2)
face diameter: D = 2 · tan α2 · (h2 + R2 + R2sin(α/2))
R1, R2: radii of the small and large spheres, in mm · h1, h2: depth of the top of the spheres below the face, in mm (negative if the sphere protrudes) · α/2: half-angle of the cone · D: diameter of the hole in the face. The spheres are selected so that the contact point falls within the conical section, away from the chamfers.
Example 33.11 · Spindle Bore 7:24

The 7:24 tapered seat of a 40-mm spindle is checked using two balls measuring 28 and 36 mm. The depth micrometer reads h₁ = 41.40 mm for the small ball and h₂ = 9.70 mm for the large one. The nominal half-angle of the 7:24 taper is 8°17′50″ (table in Section 6.2). What is the angle and the diameter at the mouth of the taper?

R₁ = 14 mm, R₂ = 18 mm → R₂ − R₁ = 4 mm
denominator: (41.40 − 9.70) + (14 − 18) = 31.70 − 4 = 27.70 mm
sin(α/2) = 4 / 27.70 = 0.144404 → α/2 = 8.3028° = 8°18′10″
error: 8°18′10″ − 8°17′50″ = +20″
distance from the vertex to the face: 9.70 + 18 + 18 / 0.144404 = 27.70 + 124.65 = 152.35 mm
D = 2 · tan 8.3028° · 152.35 = 2 · 0.14593 · 152.35 = 44.466 mm
α/2 = 8°18′10″ (20″ wider than nominal) · mouth diameter 44.466 mm
⚠️
Sensitivity. In the formula, the difference h₁ − h₂ is what matters: an error of 0.01 mm in one of the two depths changes the denominator by 0.01 out of 27.70 and the angle by approximately 11″ in this example. The more different the spheres are, the farther apart the depths are, and the less significant the reading errors become.

33.9 Tapered Gauges, Prussian Blue, and Contact Range

During production, the cones are checked using conical gauges: the plug for internal cones and the ring for external ones. The gauge has the exact taper and, near the larger end, two notches (or a step) that indicate the tolerance for the axial position: when inserted without forcing it, the face of the workpiece must fall between the two notches. This checks the diameter; the angle is checked using Prussian blue.

Apply a very thin layer of blue to the gauge (or the male part), insert it, rotate it a quarter turn while applying light pressure, and then remove it. Where the surfaces touch, the blue is transferred or removed. The mark length is the portion of the cone’s length that bears the mark.

  • even contact along the entire length: the right angle;
  • contact only along the larger diameter: the male part is wider than the gauge (or the female part is narrower);
  • contact only along the smaller diameter: the male part is more closed;
  • patchy marks or marks on only one side: the cone is oval-shaped or crooked relative to its axis.

For tool holders, the required length is typically at least two-thirds or three-quarters of the total length, with a greater proportion toward the larger diameter, where the seat must center more accurately: the exact value can be found on the drawing or in the holder standard.

two notchesconical plugThe surface of the workpiece mustfall between the two notchesconical ringstep in place of the notchesfull contactonly at the large diameterblue marks on the maleLarge diameter at the top; if it touchesonly at one point, the angle is incorrect
Figure 33.15 · On the left, the conical plug in its seat: the workpiece surface must lie between the two notches. In the center, the conical ring with the step. On the right, the blue markings: full contact (correct) and contact only toward the larger diameter (incorrect angle).

The markings are read in millimeters along the axis, but they indicate a diameter: an axial displacement Δz corresponds to a difference in diameter ΔD = C · Δz, where C is the taper ratio. In very tight tapered cones, such as Morse taper, a large displacement results in a small difference in diameter: this is why the taper gauge is so sensitive.

Axial Position and Diameter
ΔD = C · Δz Δz = ΔDC
ΔD diameter difference in mm · C taper (pure number, e.g., 1/19.922 for Morse 3) · Δz offset of the face relative to the notch, along the axis, in mm
Example 33.12 · The Morse 3 tap that goes in too far

A Morse 3 tap (C = 1 : 19.922) enters a new thread 1.2 mm past the reference mark. How much larger is the seat? And in a 7:24 seat, how far must the face move for a diameter difference of 0.01 mm?

Morse 3: ΔD = 1.2 / 19.922 = 0.060 mm
7:24: Δz = 0.01 / (7/24) = 0.01 / 0.29167 = 0.034 mm
The Morse seat is 0.06 mm larger in diameter; at 7:24, one hundredth of a diameter shifts the face by only 34 µm

33.10 Morse Taper and 7:24 in the workshop

If you don't have a micrometer, you can check a cone using standard workshop tools. There are three commonly used methods:

  • two rollers and blocks (paragraph 33.7) for the disassembled outer cones;
  • two spheres (paragraph 33.8) for the seats;
  • The dial indicator on the lathe, with the workpiece still in the machine: mount the dial indicator on the turret with the tip exactly at the center height, zero it to a point on the generatrix, move the carriage in the Z-axis by a known length, and read the change. The reading represents a change in radius; therefore, the taper is twice the reading divided by the displacement.
spindle12Z-axis travel = 40 mm (on the vernier scale or display)The dial indicator tip is at the center height: it measures the change in radiusReading at 1: 0Reading at 2: −5.860
Figure 33.16 · The cone is still in the machine: the comparator moves from position 1 to position 2 by shifting the slide 40 mm in the Z direction. If the tip is not at the center height, the comparator reads a value less than the actual change in radius.
Cone checked with the Z-axis comparator
C = 2 · ΔrΔz tan α2 = ΔrΔz
Δr: comparator reading difference (change in radius) in mm · Δz: displacement along the axis in mm · C: taper · α/2: half-angle
Example 33.13 · A 7:24 cone still on the lathe

The 7:24 taper of a tool holder is being turned. When the carriage is moved 40 mm toward the smaller diameter, the dial indicator reading changes from 0 to −5.860 mm. What is the taper of the workpiece? What reading was expected?

Calculate the absolute value: Δr = 5.860 mm; expected value: Δr = 40 · (7/24) / 2 = 40 · 0.145833 = 5.833 mm
workpiece: C = 2 · 5.860 / 40 = 0.2930 (7:24 equals 0.29167)
tan(α/2) = 5.860 / 40 = 0.1465 → α/2 = 8°20′4″ (nominal 8°17′50″)
The cone is 2′14″ too wide: adjust the angle of the slide or the program before finishing
Example 33.14 · The Morse 4 shank with rollers

The Morse 4 shank (C = 1 : 19.254) of a spindle is measured using two rollers and 50-mm gauges. What difference M₁ − M₂ is expected? The measurement yields 2.610 mm: what is the taper of the shank?

Expected value: M1 − M2 = 2 · H · tan(α/2) = H · C = 50 / 19.254 = 2.597 mm
measured: C = 2.610 / 50 = 0.05220 → 1 : 19.16
semi-angle: tan(α/2) = 2.610 / 100 = 0.02610 → 1°29′42″ (nominal 1°29′15″)
Over a 100-mm cone, the diameter differs by (0.05220 − 0.05194) × 100 = 0.026 mm more than it should
The tang is 27″ wider: it only touches the larger diameter, and you'd see it right away if it were blue

33.11 Dividing heads, dividers, and rotary tables

Indexing heads and dividing plates are used to rotate a workpiece to precise angles for milling teeth, equidistant slots, and the faces of a polygon. They also serve as measuring instruments: their graduations act as angle standards.

In the direct division A disk with N is usedd holes (usually 24) mounted on the spindle: to divide into N parts, advance by Nd/N holes, so only the divisors of 24 (2, 3, 4, 6, 8, 12, 24) are used. In the indirect division The spindle is driven by a 40-tooth gear and a worm gear: 40 turns of the crank result in one revolution of the workpiece. To divide the workpiece into N parts, the crank must turn 40/N times; the fractional part is determined by counting the holes in a circle on the perforated disc, using the scissor sector.

40-tooth wheelworkpiece-holding spindlesingle-start worm screwperforated disc(rims with 17,18, and 20 holes)crank withpin (in red)scissor-type sector40 crankshaft revolutions = 1 revolution of the workpiece
Figure 33.17 · Diagram of the counting head: the crank turns the worm screw, which drives the 40-tooth spindle wheel. The scissor-shaped sector encompasses the number of holes to be counted each time.
Indirect Division
nm = 40N angular division: nm = β9°
nm crank revolutions per division · N number of parts · β angle by which to rotate the workpiece (one crank revolution rotates the workpiece by 360°/40 = 9°). The fractional part is marked as holes on a circle on the disc: a standard set of discs has circles with 15, 16, 17, 18, 19, 20 / 21, 23, 27, 29, 31, 33 / 37, 39, 41, 43, 47, 49 holes.
Example 33.15 · Direct and Indirect Division

We need to mill 8 slots on a shaft and then 17 teeth on a gear. How do we divide the work?

8 holes, direct drilling with a 24-hole drill bit: 24 / 8 = 3 holes at a time
17 teeth, indirect: 40 / 17 = 2.3529 = 2 + 6/17 revolutions
Use the 17-hole circle: 2 full turns and 6 holes; the sector spans 6 spaces
8 holes: 3 holes in the direct-mount disc · 17 teeth: 2 turns and 6 holes on the 17-inch rim
Example 33.16 · Rotate the workpiece by 23°30′
23°30′ = 23.5° → nm = 23.5 / 9 = 2.6111 revolutions = 2 + 0.6111
0.6111 = 11/18 → 2 turns and 11 holes on the 18-inch rim
Verification: 11/18 · 9° = 5.5° = 5°30′; 2 · 9° + 5°30′ = 23°30′ ✓
2 laps and 11 holes on the 18-inch rim

The Rotary Table as a Measuring Instrument

A precision rotary table, with a scale read under a microscope or using an encoder, measures angles between elements of a workpiece: center the workpiece, bring a dial indicator (secured to a support) into contact with the first element and zero it, rotate the table until the dial indicator returns to zero on the second element, and read the rotation. The angular error, multiplied by the radius, indicates how far the element is displaced along the circumference. These tables are in turn checked using an optical polygon (section 33.12) or a reference table.

Example 33.17 · Two holes at 72° on a flange

Two holes in a flange must be spaced 72°00′ apart on a circle with a radius of 80 mm. On the rotary table, the rotation between the two zeroing positions is 72°00′18″. How much is the second hole offset?

error: 18″ = 18 × 4.848 × 10−6 = 8,73 · 10−5 rad
Circumference displacement: 80 × 8.73 × 10−5 = 0.0070 mm
The hole is offset by 7 µm along the rim: for a positional tolerance of a few hundredths, this is negligible

33.12 The Autocollimator and Optical Polygons

An autocollimator is a telescope that measures very small rotations of a mirror. A lamp illuminates a reticle located in the focal plane of the objective lens: the rays emerge parallel, strike a flat mirror, and return. If the mirror is perpendicular to the beam, the image of the reticle coincides exactly with the reticle itself. If the mirror rotates by θ, the reflected beam returns at an angle of 2θ (reflection doubles the angle), and the image shifts in the focal plane by s = f · tan 2θ. The displacement is read using an ocular micrometer or an electronic sensor, which has already converted the measurement to seconds.

The beauty of this instrument is that the displacement does not depend on the distance to the mirror, because the beam is parallel: the mirror can be just a few centimeters away or a few meters away.

lampbeam splitterfocal plane (reticle)lensfmirroron the bases2θθIf the mirror rotates by θ, the beam returns at an angle of 2θand the image shifts by s = f · tan 2θ
Figure 33.18 · The beam exits the objective (yellow) in parallel and is reflected by the mirror inclined by 2θ (red dashed line): in the focal plane, the image of the reticle shifts by s. The angles are greatly exaggerated.
Autocollimator
s = f · tan 2θ ≈ 2 · f · θrad Δh = b · θrad
s: displacement of the image in the focal plane, in mm · f: length of the lens, in mm · θ: rotation of the mirror · Δh: height difference between the support points at the base of the mirror, in mm · b: base spacing (distance between the support points), in mm
Example 33.18 · How far does the image shift?

An autocollimator has a focal length of f = 500 mm. How far does the image shift if the mirror rotates by 10″?

10″ = 10 · 4,848 · 10−6 = 4,848 · 10−5 rad
s = 2 · 500 · 4,848 · 10−5 = 0.0485 mm
Almost 5 cents per 10″: an ocular micrometer reads them effortlessly, and that’s why we end up with a tenth of a second

Straightness at Small Angles

The mirror is mounted on a base with two supports spaced b apart (for example, 100 mm) and is moved along a guide in increments of b, each increment attached to the previous one. At each step, the autocollimator reads the inclination of the base: multiplied by b, this gives the amount by which the front support rises or falls relative to the rear one. By summing the height differences, the profile of the guide is reconstructed. This is a measure of straightness, which Chapter 34 covers in full, including how to process the data (the reference line and the tolerance); the electronic level is used in the same way.

Example 33.19 · The profile of a guide rail in 100-mm increments

With a 100-mm base, the readings, in successive steps, are 0″, +2″, +5″, +3″, −1″, −4″. Reconstruct the profile.

1″ per 100 mm = 100 × 4.848 × 10−6 mm = 0.485 µm
elevation changes: 0 · +0.970 · +2.424 · +1.454 · −0.485 · −1.939 µm
progressive sums: 0 · 0.970 · 3.394 · 4.848 · 4.363 · 2.424 µm
The guide has a bulge of about 4.8 µm at 300 mm from the start (Figure 33.19, left)

An optical polygon is a glass or steel prism with 8, 12, 24, or more mirror-polished faces, with angles between the faces known to the nearest tenth of a second. Mounted on a rotary table or a dividing head, with the autocollimator aimed at one face, it allows for checking the division: the table is rotated by 360°/N, and if the table is perfect, the autocollimator reads the same value on the next face. Any differences represent the division errors of the turntable.

Controlled feed in 100-mm increments0.01.03.44.84.42.4heights in µm (example 33.19)mirror on a 100 baseautocollimator12-facet polygon (30°) on the rotary table
Figure 33.19 · On the left is the profile of the guide rail from Example 33.19, reconstructed by summing the height differences (vertical scale greatly magnified). On the right is a 12-sided polygon on the rotary table, with the autocollimator aimed at one of its faces.
Example 33.20 · Checking a table using a 12-sided polygon

A 12-sided polyhedron is mounted on a rotary table. At every 30° rotation, the autocollimator—zeroed on the first face—reads the following values on the next face: 0″, +3″, +5″, +2″, −2″, ... What is the error of the turntable at the 60° position?

At the 60° position (third reading), the autocollimator reads +5″: the face of the polygon has not returned to a perpendicular position relative to the beam, so the table has rotated 60° ± 5″ (the reading depends on the direction of rotation and the reading direction)
within a radius of 100 mm: 100 · 5 · 4.848 · 10−6 = 0.0024 mm
Division error of 5″ at 60°, equal to 2.4 µm on a 100 mm radius (excluding errors in the polygon, as stated on its certificate)

33.13 Angles Measured with the Measuring Machine, Tool Angles, and Chamfers

With a coordinate measuring machine (CMM), the angle is not measured—it is calculated. The machine probes several points on each surface, determines the plane or line that best approximates them, and calculates the angle between their directions. This method is used for angles between distant faces, between a hole and a face, or on workpieces that cannot be placed on a sine bar. The machine’s operation and its probing strategies are described in Chapter 37.

Example 33.21 · The Angle Formed by Two Given Points

On a tilted plane, the CMM probes two points in the XY plane: P₁(12,000; 3,500) and P₂(42,000; 20,820), while the reference face is parallel to the X-axis. What is the angle of the side?

ΔX = 42,000 − 12,000 = 30,000 mm · ΔY = 20,820 − 3,500 = 17,320 mm
tan β = 17.320 / 30.000 = 0.57733 → β = 29.9993° = 29°59′57″
β ≈ 30°00′; however, with only two points, the side shape error is entirely reflected in the result: the machine detects more and more of it

Tool Angles

The rake, cutting, and setting angles of a tool (Chapter 24) are checked using a tool protractor—a small set square with a graduated sector that rests on the base of the shank—or with a profile projector or optical presetters. A precise workshop method uses a lever-type dial indicator: the tool is placed on a flat surface, the indicator is lowered along the side of the tool, and the horizontal displacement of the tip is read for a known vertical travel.

toolαreading andhlever comparator that moves down along the side:the vertical displacement h and the reading e give αtool resting on the base facereticle lineshadow of the workpieceprojector screen with reticlerotatable, read in degrees and minutes
Figure 33.20 · On the left, the profile of a tool: the lever-type comparator moves down a distance of h along the flank, and the displacement e is read. On the right, the shadow of a chamfer on the projector screen: rotate the crosshair until it aligns with the edge, and read the angle.
Example 33.22 · The tool clearance

The lever-type depth gauge moves down 5 mm along the main flank of a tool, and its reading changes by 0.61 mm. What is the tool's rake angle?

tan α = 0.61 / 5 = 0.122 → α = arctan 0.122 = 6.956° = 6°57′21″
A drop of about 7°

The Size of the Chamfers

A chamfer has two specifications: the width (or length) and the angle. The most common tools are:

  • the hole chamfer gauge: a 90° (or 60°, 120°) conical probe that fits into the chamfer and directly reads the chamfer diameter on its face;
  • the profile projector and workshop microscopes, with a rotating reticle graduated in degrees and minutes: the width, height, and angle of the chamfer are measured at 10x or 20x magnification;
  • Snap-action gauges and 45° chamfer templates, for quick inspection during production.
Example 33.23 · Chamfers Using a Projector and a Hole Gauge

On the projector, an external chamfer with the drawing dimensions “1.5 × 30°” measures 1.48 mm in length and 0.85 mm in height. What is its angle? A Ø10 hole with a 90° chamfer measures 12.4 mm in diameter on the chamfer gauge: how wide is the chamfer?

tan β = 0.85 / 1.48 = 0.5743 → β = 29.870° = 29°52′11″
hole: width = (12.4 − 10) / 2 = 1.2 mm; at 90° (45° per side), the depth is also 1.2 mm
29°52′ external chamfer (8′ less than 30°) · 1.2 × 45° hole chamfer

33.14 Common Errors in Angle Measurement

Many errors are common to all measurements (Chapter 31): temperature, dirt, parallax, and measurement force. Some, however, are specific to angles.

ErrorReasonRemedy
Supplementary or Complementary AngleRead the angle between the parts of the instrument, not the angle shown on the drawingMake a sketch before reading; check visually to see if the angle is acute or obtuse.
Wrong half of the vernier scaleLook for the intersection on the opposite side from where the degrees increase.Check that the reading + line · 1°55′ equals one full degree
Tool not perpendicular to the edgeThe blade or base is at an angle to the corner edge: the angle measured “in perspective” is larger.Keep the instrument's surface perpendicular to the edge
Zero on the levelThe vial is not parallel to the base.Inversion method (Example 33.6)
Dirty or loose blocksA thin film of oil or a droplet just a few µm thick changes Hclean, secure, check the stack on the surface
Chin-up bar used at an angle greater than 45°The breast changes little: H errors have a significant impact on the angleTurn the workpiece over and measure the complement
Off-center controlled coneThe tip of the comparator is not aligned with the axis.Center the tip (find the point where the reading reverses)
A burr or sharp edge under the squareThe base does not rest on the surfaceDeburr the workpiece, clean the work surface
A straight line mistaken for an angleThe face is curved: the angle depends on where the instrument rests.First, check the flatness (Chapter 34)

For the sine bar, it is useful to know how much an error on the blocks affects the result. Deriving H = L · sin α, we find dα = dH / (L · cos α): the angular error increases as 1/cos α, that is, slowly up to 45° and very rapidly near 90°.

Sensitivity of the sine bar
dαrad = dHL · cos α
dα: angle error in radians · dH: error in stack height in mm · L: distance between rollers in mm · α: angle of the bar
Example 33.24 · How much does a micrometer cost at Blocchetti?

100 mm sine bar: What angular error results in an error of 1 µm on the stack at 10°, 45°, 60°, and 80°? And what about a 5 µm misalignment in Example 33.8 (22°30′)?

10°: 0,001 / (100 · 0,98481) = 1,015 · 10−5 rad = 2.1″
45°: 0,001 / (100 · 0,70711) = 1,414 · 10−5 rad = 2.9″
60°: 0,001 / (100 · 0,5) = 2 · 10−5 rad = 4.1″
80°: 0,001 / (100 · 0,17365) = 5,76 · 10−5 rad = 11.9″
22°30′ at 5 µm: 0.005 / (100 · 0.92388) = 5.41 · 10−5 rad = 11.2″
From 2″ to 12″ per micrometer; the dirty battery in Example 33.8 shifts the measurement by 11″, about one-tenth of the ±2′ tolerance

33.15 The Formulas in This Chapter

What Are You Looking For?Formula
Small angle as a slopee = L · tan θ ≈ L · θrad · 1″ = 4,848 · 10−6 rad
Out of sync with the sliver of lightθ ≈ f / h
Angular vernier scalea = p / 12 = 5′ · reading = degrees + line · 5′
Leveli = n · S · e = i · L · R = p / (S/1000)
Reversing the spirit leveli = (r1 − r2) / 2 · error = (r1 + r2) / 2
C-bar (Chapter 6)H = L · sin α · error ≈ Δ / l
Sensitivity of the sine bardα = dH / (L · cos α)
Outer cone with two rollerstan(α/2) = (M1 − M2) / (2H) · D = M1 − dr · (1 + cot(45° + α/4))
Inner cone with two ballssin(α/2) = (R2 − R1) / ((h1 − h2) + (R1 − R2))
Axial Position in the Conical GaugeΔD = C · Δz
Cone with Z-axis comparatorC = 2 · Δr / Δz · tan(α/2) = Δr / Δz
Indirect Divisionnm = 40 / N · nm = β / 9°
Autocollimators = f · tan 2θ ≈ 2 · f · θ · Δh = b · θ

33.16 Exercises

Try to solve them on your own, using a calculator, before looking at the solution. In the first three, the degrees increase as you go to the right.

Exercise 1. Look at the protractor drawing shown below.
2010010203060453015015304560main scale in degrees (top) · vernier scale in primes (bottom)
Figure 33.21 · Exercise 1.
Solution

The zero mark on the vernier scale is between 8° and 9°: 8°. On the right, it aligns with the third line (where “15” is marked): 3 × 5′ = 15′. Reading: 8°15′. Verification: 3 × 1°55′ = 5°45′ and 8°15′ + 5°45′ = 14°00′. The alignment visible on the left (the 45′ line) does not count.

Exercise 2. Look at the protractor drawing shown below.
40506070809060453015015304560main scale in degrees (top) · vernier scale in primes (bottom)
Figure 33.22 · Exercise 2.
Solution

Zero is between 63° and 64°: 63°. On the right, it coincides with the tenth line (the first after 45): 10 × 5′ = 50′. Reading: 63°50′. Verification: 10 × 1°55′ = 19°10′ and 63°50′ + 19°10′ = 83°00′ (on the 0-90-0 scale, the line coincides with 83).

Exercise 3. Look at the protractor shown below. If the drawing provides the dimensions for the obtuse angle between the two measured sides, what are they?
0102030405060453015015304560main scale in degrees (top) · vernier scale in primes (bottom)
Figure 33.23 · Exercise 3.
Solution

Zero between 29° and 30°: 29°. The first line to the right of zero corresponds to: 5′. Reading: 29°05′ (verification: 29°05′ + 1°55′ = 31°00′). The obtuse angle between the faces is 180° − 29°05′ = 179°60′ − 29°05′ = 150°55′.

Exercise 4. A square block resting on a face has a gap estimated at 0.01 mm at a distance of 200 mm from the point of contact. By what angle is the face out of square? What is the value in mm/m?
Solution

θ = 0.01 / 200 = 0.00005 rad = 0.00005 / 4.848 × 10−6 = 10.3″; with a slope of 0.05 mm/m.

Exercise 5. A 0.05 mm/m spirit level placed on a 1.2 m-long machine base shows 4 divisions. Calculate the slope, the difference in height, and the angle in seconds.
Solution

i = 4 × 0.05 = 0.2 mm/m; e = 0.2 × 1.2 = 0.24 mm; 4 × 10.31″ = 41.3″.

Exercise 6. A 100-mm sine bar is used to measure an angle of 18°20′. Calculate the stack and assemble it using the set of 112 workpieces.
Solution

18°20′ = 18.3333°; H = 100 · sin 18.3333° = 100 · 0.314545 = 31.454 mm; 1.004 + 1.45 + 4 + 25 = 31.454 mm ✓.

Exercise 7. A 200-mm sine bar is to be bent to a 34° angle. Calculate the bend depth and set it up. On a 100-mm bar with a bend depth of 42.262 mm, what is the angle of the bend?
Solution

H = 200 · sin 34° = 200 · 0.559193 = 111.839 mm = 1.009 + 1.33 + 9.5 + 100 ✓. Second case: sin α = 0.42262 → α = 25.0001° ≈ 25°00′00″.

Exercise 8. An external cone, with its large base at the bottom, is measured using two 25-mm rollers and stacks: M₁ = 48.62 mm and M₂ = 45.98 mm. What is the half-angle?
Solution

tan(α/2) = (48.62 − 45.98) / (2 × 25) = 2.64 / 50 = 0.0528 → α/2 = 3.0224° = 3°1′21″.

Exercise 9. A conical hole is measured using 20-mm and 30-mm spheres: the apexes lie at h₁ = 36.20 mm and h₂ = 12.50 mm below the face. Calculate the half-angle.
Solution

sin(α/2) = (15 − 10) / ((36.20 − 12.50) + (10 − 15)) = 5 / (23.70 − 5) = 5 / 18.70 = 0.26738 → α/2 = 15.508° = 15°30′30″.

Exercise 10. A Morse 2 plug (C = 1 : 20.020) fits into a socket 0.9 mm shorter than the reference mark. How much smaller is the socket’s diameter?
Solution

ΔD = 0.9 / 20.020 = 0.045 mm: The seat is 0.045 mm smaller than the reference diameter.

Exercise 11. Using mental division (ratio 40:1), you must perform 36 divisions, then 52 divisions, and then rotate the workpiece by 7°40′. How do you proceed using the set of discs described in paragraph 33.11?
Solution

36: 40/36 = 1 + 1/9 = 1 revolution and 2 holes on the 18-hole rim. 52: 40/52 = 10/13 = 30/39 → 30 holes on the 39-hole rim. 7°40′ = 7.6667°; 7.6667 / 9 = 0.85185 = 23/27 → 23 holes on the 27-hole rim (verification: 23/27 · 9° = 7.6667° = 7°40′).

Exercise 12. In an autocollimator with f = 400 mm, the image shifts by 0.0233 mm. By how much has the mirror rotated? If the mirror is mounted on a 100-mm base, what is the height difference between its supports?
Solution

θ = s / (2f) = 0,0233 / 800 = 2,9125 · 10−5 rad = 6.0″; Δh = 100 × 2.9125 × 10−5 = 0.0029 mm ≈ 2.9 µm.

Exercise 13. The lever comparator moves down 4 mm along the flank of a tool, and the reading changes by 0.44 mm. What is the tool’s rake angle?
Solution

tan α = 0.44 / 4 = 0.11 → α = 6.277° = 6°16′38″.