Angles and Cones
An angle that’s off by just a few prism units isn’t visible to the naked eye, but you can feel it: a guide that doesn’t slide smoothly, a Morse taper that wobbles in the tube, a workpiece that doesn’t fit together with another. In this chapter, we review all the tools used in the workshop and metrology lab to check angles and cones, from the set square held up to the light to the autocollimator that measures to a tenth of a second. For each instrument, we’ll examine its design, how to read it, and how to set it up, with new numerical examples. The calculations for cones, sine bars, and rollers are already covered in Chapter 6; here, we’ll refer back to them and use them for measurements.
33.1 Angles in the Workshop: Units and Orders of Magnitude
Angles are measured in sexagesimal degrees: A full circle is 360°, a degree is 60 primes (60′), and a prime is 60 seconds (60″). Drawings and numerical calculations often use decimal degrees (12.5° instead of 12°30′), while trigonometric formulas work in radiant. The conversions are explained in section 2.10; here, it is especially important to understand How big is it? a small angle, because in metrology, angular errors are almost always expressed in primes and seconds.
The most practical way is to think of a small angle as a slope: how many millimeters you climb per meter of length. For small angles, tan θ ≈ θ (in radians), so the elevation gain is simply length times the angle.
A tilted plane is at an angle of 0°12′ relative to the horizontal. How much does it rise over a distance of 400 mm? And a surface that is out of square by 0.3 mm over a distance of 500 mm—by what angle is it out of square?
| Tool | Typical resolution | Usage |
|---|---|---|
| Simple Protractor | 1° | tracking, rough checks |
| Universal protractor with vernier scale | 5′ | any corner of the workshop |
| Digital Protractor | 0,01°-0,05° (36″-3′) | workshop, assembly |
| Precision Spirit Level | 0.02 mm/m (≈ 4″) | bubble-wrapped, pallets |
| C-frame with blocks and dial indicator | a few seconds | Angle and Cone Inspection |
| Electronic level | 0.001–0.01 mm/m (0.2″–2″) | machine geometry |
| Autocollimator | 0,1″-1″ | straight lines, dividers, polygons |
These are approximate values, which vary by manufacturer.
33.2 Squaring and Checking Perpendicularity
The angle that is checked most often is the right angle. The set square is the physical embodiment of 90°: a workpiece of hardened and ground steel (or granite) with two faces that are perpendicular to each other within a few micrometers. There are three main types.
- Flat square: a thick L-shaped sheet of metal with the edges of both arms ground smooth. It is used for marking and visual inspections.
- Team in a Hat (or base-mounted): a thin blade attached to a thick base. The base rests securely on the reference surface or against one side of the workpiece, while the blade checks the other side. It is the quintessential workshop square; the best ones have a blade with chamfers (like a knife) to better catch the light.
- Square cylinder: a ground cylinder with bases perpendicular to its axis. When placed on a flat surface, its outer surface forms a perfect vertical line that touches the workpiece along a single generatrix; this makes it very easy to read the clearance. It is also used as a reference for calibrating other squares.
The light-slit test
Place the base of the set square on the surface (or on the reference face of the workpiece), gently bring the blade close to the face to be inspected, and look at it against the light, with a bright background behind it. If the surfaces are perpendicular, no light passes through; if not, a wedge of light is visible, starting at zero on one side and widening toward the other. A trained eye, under good lighting, can detect gaps of 2–3 µm. To estimate the width, compare the gap to a reference gap: place two blocks of different thicknesses (for example, 10.000 and 10.005 mm) on the surface, rest a ruler on top, and the gap between the ruler and the lower block is 5 µm wide.
A milled plate is placed on the surface and checked with a hat-shaped square. The blade touches at the bottom and top; at a height of 120 mm, the gap is estimated to be 0.015 mm (between the 10- and 20-µm reference gaps). How out of square is the face?
When a precise measurement is needed rather than an estimate, a comparator mounted on a column or on a carriage that slides along the table is used instead of the blade: it is zeroed at the bottom against the square cylinder, the reading is taken at the top, and then the same procedure is repeated on the workpiece. The difference between the two readings, divided by the height, gives the perpendicularity error. The actual inspection of perpendicularity tolerances is covered in Chapter 34.
33.3 Simple Protractors and Universal Protractors with a Vernier Scale
The simple protractor A workshop protractor is a semicircular sector graduated in degrees, with a support base and a swiveling arm with a pointer. It is used for marking and checking where a degree of uncertainty is sufficient, such as the angle of a bent sheet of metal or a weld bead. Be careful which angle you read: the instrument measures the angle between the base and the arm, which may be the complementary angle (180° minus) of the angle you are interested in.
The universal goniometer (also known as a bevel protractor) is a workshop tool for measuring any angle. It consists of a base, a fixed dial graduated in degrees from 0 to 90 and back (0-90-0-90), and a rotating disc that holds the vernier scale and the blade, which slides and locks into place at any stick-out. A locking ring blocks the disk, and a magnifying lens enlarges the vernier scale; many models include an accessory for measuring acute angles. The resolution is 5 primes.
The 5′ vernier scale
The angular vernier works like the one on a caliper (Chapter 32), but with degrees instead of millimeters. On the rotating disc, on either side of zero, there are 12 divisions that cover a total of 23° of the main scale. Each division of the vernier scale is therefore 23°/12 = 1°55′, or 5′ less than two degrees. When the zero mark on the vernier is aligned with a whole degree, vernier line 1 is 5′ before the second degree, vernier line 2 is 10′ before the fourth, and so on. If you rotate the disk by 5′, line 1 aligns; by 10′, line 2 aligns; and by 55′, line 11 aligns.
There are three rules for reading.
- Read the whole degrees on the main scale, up to the zero mark on the vernier scale, in ascending numerical order;
- Find the vernier scale line that coincides with a line on the scale, on the same side as the degrees increase: the number on that line gives the prime numbers;
- On the other half of the vernier scale, there is always a second alignment (that of 60′ minus the first exact value): this should not be taken into account.
Read the protractor in Figure 33.6, where the degrees increase to the right.
The protractor shown in Figure 33.7 is mounted with its base on one face of a support and its blade on the inclined side. What angle does it read? If the drawing provides dimensions for the obtuse angle between the two faces, what is its measure?
33.4 Digital Levels, Inclinometers, and Goniometers
A spirit level does not measure the angle between two surfaces, but rather the inclination of a surface relative to the horizontal—that is, relative to gravity. Inside the vial—a glass tube curved with a very large radius and filled with liquid—the air bubble always rises to the highest point. The graduations on the vial are usually spaced 2 mm apart.
The sensitivity of a spirit level is the angle of inclination that causes the bubble to move by one division. It is expressed in mm/m: “0.02 mm/m” means that if the bubble moves by one division, the surface rises by 0.02 mm per meter. Mechanics’ levels have a sensitivity of 0.02 or 0.05 mm/m, while fitters’ levels have a sensitivity of 0.1 mm/m or higher. The more gently curved the vial is (larger radius), the more sensitive the level is.
A level with a sensitivity of 0.02 mm/m, placed on a 1.6-meter-long bench, shows the bubble shifted 3 divisions to the right (Figure 33.8). How much is the bench inclined? How much higher is the right end? What is the radius of the vial, with 2-mm graduations?
The Inversion Method
No spirit level has a perfect zero reading. To avoid relying on its error, take two readings: one normally and one after rotating the level 180° at the same point, marking the positions of the ends with a pencil. The spirit level’s error does not change sign, but the surface’s inclination does: the half-difference of the readings is the true inclination, and the half-sum is the spirit level’s error (which can be corrected using its adjustment screw).
Using a spirit level with a sensitivity of 0.02 mm/m, the reading is +2 divisions (bubble to the right). When rotated 180° at the same point, the reading is −0.5 divisions (bubble to the left, still viewed from the same side). What is the angle of the surface?
Electronic levels, inclinometers, and digital protractors
An electronic level replaces the bubble with a pendulum or a capacitive sensor and displays the inclination on a screen, in mm/m or in seconds. The best models have a resolution of 0.001 mm/m (approximately 0.2″) and can operate in differential mode: two probes, one on the fixed part and one on the part being checked, and the instrument displays the difference, thereby canceling out floor vibrations. They are the standard tool for geometric testing of machine tools.
The digital inclinometers shop-calibrated (resolution 0.05° or 0.1°) and the digital protractors These two-arm instruments, featuring an encoder in the pivot (resolution 0.01°), are convenient for surveying: they can be zeroed on any surface (ZERO button) and measure the relative angle, or they can measure relative to the horizontal (ABS mode).
The table of a 800-mm-long milling machine is checked with an electronic level, which reads +0.037 mm/m. What is the slope in seconds, and how much does the table rise from one end to the other? What reading would be shown on a digital protractor with a resolution of 0.05°?
33.5 Combination Square and Fixed Angle Gauges
The combination tool is a graduated steel rail with a groove, on which three different heads slide and lock into place:
- a square, with one face at 90° and one at 45°, and often a small level: used for marking lines, checking 45° chamfers and bevels, and measuring depth;
- the goniometric head, a simple protractor with a spirit level that locks at the desired angle;
- The V-shaped center-finding tool: when placed on a shaft, the line passes exactly through the center and allows you to mark it on the face.
When you need to check the same angle on multiple workpieces, it’s not practical to measure it each time: instead, use a fixed gauge (template)—that is, a steel strip with the correct angle cut into the edge. Place it against the workpiece and check the gap, just as you would with a set square. The most common ones are:
- V-shaped or edge profiles at 30°, 45°, 60°, 90°, and 120°, often grouped together in a bundle;
- The tap sharpening gauge: It has a flank angle of 59° from the axis (half of the 118° of a standard tap) and a scale to check that the two cutting edges are the same length. A drill bit with unequal cutting edges produces a hole larger than its diameter (Chapter 28);
- the “fishtail” gauge for threading tools: it has 60° grooves (metric threads) or 55° grooves (Whitworth) and is used both to sharpen the tool and to position it perpendicular to the workpiece on the lathe;
- comb-type thread gauges, which check the pitch and angle of the thread by comparison (Chapter 35).
33.6 The sine bar and the sine plane
The sine-bar theory is described in Section 6.12: two rollers separated by a distance L, a stack of blocks of height H beneath one roller, and the bar is inclined at an angle such that sin α = H/L. Here we see how it is actually used to check an angle, which is the most common application in the metrology lab. The sine plane is essentially the same concept on a larger scale: a plane with rollers and a hinged base, on which the workpiece is secured with clamps or a magnet; it is also used in grinding to achieve precise angles.
The Step-by-Step Procedure
- Clean the table, bar, blocks, and workpiece; keep everything at the same temperature (paragraph 31.10);
- Calculate H = L · sin α using the nominal angle of the workpiece, and assemble the stack of blocks (see method below);
- Place the bar so that one roller rests on the work surface and the other on the stack; place the workpiece on the bar against the stop so that the surface to be inspected is horizontal;
- Place the comparator on its stand above the surface, at the beginning of the area to be checked, and zero it (or note the reading);
- Slide the support along the surface to the other end, at a distance l, and read the difference Δ;
- If Δ = 0, the angle is the nominal angle; otherwise, the error is Δ / l in radians. If the end closest to the blocks is higher, the angle of the workpiece is greater than the nominal angle.
Choosing the blocks
A standard set of flat-parallel blocks consists of 112 workpieces: 1.0005 mm; from 1.001 to 1.009 in increments of 0.001; from 1.01 to 1.49 in increments of 0.01; from 0.5 to 24.5 in increments of 0.5; and the large ones at 25, 50, 75, and 100 mm. The stack is assembled starting from the last decimal place and using as few blocks as possible, because each block adds its own error and a slight gap between the faces. The blocks are joined by friction (they are slid over one another until they “stick” together), after they have been cleaned.
A support has a face inclined at 22°30′ with a tolerance of ±2′. Check it on a 100-mm sine bar. The dial indicator, moved 60 mm along the surface, reads +0.018 mm at the end nearest the blocks. Assemble the stack and determine whether the workpiece is acceptable.
On a sine plane with L = 200 mm, the face of a mold inclined at 7°15′ must be checked. What stack is needed?
The sine bar is accurate for small and medium angles; near 90°, the sine changes very little, and every micrometer on the blocks results in a large angular error (paragraph 33.14). For angles greater than 45°, rotate the workpiece 90° and measure the complementary angle.
33.7 Measuring an external cone with two rollers and blocks
A cone can be checked on a sine bar (examples 6.18 and 6.19), but there is a method that requires only a micrometer, two identical rollers, and two stacks of identical blocks. The cone is placed on the reference surface with its larger base facing down; the two rollers are positioned on the surface in contact with the cone, on opposite sides, and the dimension M₁ above the rollers is measured with the micrometer. Then the rollers are raised onto two stacks of blocks of height H, and M₂ is measured.
As H increases, the dimension above the rollers decreases by an amount equal to the decrease in the cone’s diameter, that is, 2 · H · tan(α/2): the diameter of the rollers and their position no longer matter. The base diameter can also be derived from the first dimension, using the same principle as for a dovetail joint (Section 6.10): the roller lies in the angle between the plane and the generatrix, which here is 90° + α/2.
A conical pin has a base diameter D = 50 mm and an angle α = 14° (α/2 = 7°). When measured with 12-mm rollers and 30-mm stacks, the results are: M₁ = 72.640 mm and M₂ = 65.254 mm. What was expected? What is the angle of the workpiece, and what is the base diameter?
33.8 Measuring an Internal Cone Using Two Spheres
A micrometer won’t fit inside a conical hole, but a calibrated sphere will. The sphere stops where the hole’s diameter is just right for it, and its depth can be easily measured from the surface of the workpiece using a depth micrometer (or a dial indicator mounted on a bridge zeroed to the plane). Using two spheres of different diameters yields two depths, and the triangle formed by the two centers gives the angle.
The center of a sphere of radius R resting inside a cone lies on the axis, at a distance of R / sin(α/2) from the vertex. The difference in depth between the two centers, (h₁ + R₁) − (h₂ + R₂), is therefore (R₂ − R₁) / sin(α/2).
The 7:24 tapered seat of a 40-mm spindle is checked using two balls measuring 28 and 36 mm. The depth micrometer reads h₁ = 41.40 mm for the small ball and h₂ = 9.70 mm for the large one. The nominal half-angle of the 7:24 taper is 8°17′50″ (table in Section 6.2). What is the angle and the diameter at the mouth of the taper?
33.9 Tapered Gauges, Prussian Blue, and Contact Range
During production, the cones are checked using conical gauges: the plug for internal cones and the ring for external ones. The gauge has the exact taper and, near the larger end, two notches (or a step) that indicate the tolerance for the axial position: when inserted without forcing it, the face of the workpiece must fall between the two notches. This checks the diameter; the angle is checked using Prussian blue.
Apply a very thin layer of blue to the gauge (or the male part), insert it, rotate it a quarter turn while applying light pressure, and then remove it. Where the surfaces touch, the blue is transferred or removed. The mark length is the portion of the cone’s length that bears the mark.
- even contact along the entire length: the right angle;
- contact only along the larger diameter: the male part is wider than the gauge (or the female part is narrower);
- contact only along the smaller diameter: the male part is more closed;
- patchy marks or marks on only one side: the cone is oval-shaped or crooked relative to its axis.
For tool holders, the required length is typically at least two-thirds or three-quarters of the total length, with a greater proportion toward the larger diameter, where the seat must center more accurately: the exact value can be found on the drawing or in the holder standard.
The markings are read in millimeters along the axis, but they indicate a diameter: an axial displacement Δz corresponds to a difference in diameter ΔD = C · Δz, where C is the taper ratio. In very tight tapered cones, such as Morse taper, a large displacement results in a small difference in diameter: this is why the taper gauge is so sensitive.
A Morse 3 tap (C = 1 : 19.922) enters a new thread 1.2 mm past the reference mark. How much larger is the seat? And in a 7:24 seat, how far must the face move for a diameter difference of 0.01 mm?
33.10 Morse Taper and 7:24 in the workshop
If you don't have a micrometer, you can check a cone using standard workshop tools. There are three commonly used methods:
- two rollers and blocks (paragraph 33.7) for the disassembled outer cones;
- two spheres (paragraph 33.8) for the seats;
- The dial indicator on the lathe, with the workpiece still in the machine: mount the dial indicator on the turret with the tip exactly at the center height, zero it to a point on the generatrix, move the carriage in the Z-axis by a known length, and read the change. The reading represents a change in radius; therefore, the taper is twice the reading divided by the displacement.
The 7:24 taper of a tool holder is being turned. When the carriage is moved 40 mm toward the smaller diameter, the dial indicator reading changes from 0 to −5.860 mm. What is the taper of the workpiece? What reading was expected?
The Morse 4 shank (C = 1 : 19.254) of a spindle is measured using two rollers and 50-mm gauges. What difference M₁ − M₂ is expected? The measurement yields 2.610 mm: what is the taper of the shank?
33.11 Dividing heads, dividers, and rotary tables
Indexing heads and dividing plates are used to rotate a workpiece to precise angles for milling teeth, equidistant slots, and the faces of a polygon. They also serve as measuring instruments: their graduations act as angle standards.
In the direct division A disk with N is usedd holes (usually 24) mounted on the spindle: to divide into N parts, advance by Nd/N holes, so only the divisors of 24 (2, 3, 4, 6, 8, 12, 24) are used. In the indirect division The spindle is driven by a 40-tooth gear and a worm gear: 40 turns of the crank result in one revolution of the workpiece. To divide the workpiece into N parts, the crank must turn 40/N times; the fractional part is determined by counting the holes in a circle on the perforated disc, using the scissor sector.
We need to mill 8 slots on a shaft and then 17 teeth on a gear. How do we divide the work?
The Rotary Table as a Measuring Instrument
A precision rotary table, with a scale read under a microscope or using an encoder, measures angles between elements of a workpiece: center the workpiece, bring a dial indicator (secured to a support) into contact with the first element and zero it, rotate the table until the dial indicator returns to zero on the second element, and read the rotation. The angular error, multiplied by the radius, indicates how far the element is displaced along the circumference. These tables are in turn checked using an optical polygon (section 33.12) or a reference table.
Two holes in a flange must be spaced 72°00′ apart on a circle with a radius of 80 mm. On the rotary table, the rotation between the two zeroing positions is 72°00′18″. How much is the second hole offset?
33.12 The Autocollimator and Optical Polygons
An autocollimator is a telescope that measures very small rotations of a mirror. A lamp illuminates a reticle located in the focal plane of the objective lens: the rays emerge parallel, strike a flat mirror, and return. If the mirror is perpendicular to the beam, the image of the reticle coincides exactly with the reticle itself. If the mirror rotates by θ, the reflected beam returns at an angle of 2θ (reflection doubles the angle), and the image shifts in the focal plane by s = f · tan 2θ. The displacement is read using an ocular micrometer or an electronic sensor, which has already converted the measurement to seconds.
The beauty of this instrument is that the displacement does not depend on the distance to the mirror, because the beam is parallel: the mirror can be just a few centimeters away or a few meters away.
An autocollimator has a focal length of f = 500 mm. How far does the image shift if the mirror rotates by 10″?
Straightness at Small Angles
The mirror is mounted on a base with two supports spaced b apart (for example, 100 mm) and is moved along a guide in increments of b, each increment attached to the previous one. At each step, the autocollimator reads the inclination of the base: multiplied by b, this gives the amount by which the front support rises or falls relative to the rear one. By summing the height differences, the profile of the guide is reconstructed. This is a measure of straightness, which Chapter 34 covers in full, including how to process the data (the reference line and the tolerance); the electronic level is used in the same way.
With a 100-mm base, the readings, in successive steps, are 0″, +2″, +5″, +3″, −1″, −4″. Reconstruct the profile.
An optical polygon is a glass or steel prism with 8, 12, 24, or more mirror-polished faces, with angles between the faces known to the nearest tenth of a second. Mounted on a rotary table or a dividing head, with the autocollimator aimed at one face, it allows for checking the division: the table is rotated by 360°/N, and if the table is perfect, the autocollimator reads the same value on the next face. Any differences represent the division errors of the turntable.
A 12-sided polyhedron is mounted on a rotary table. At every 30° rotation, the autocollimator—zeroed on the first face—reads the following values on the next face: 0″, +3″, +5″, +2″, −2″, ... What is the error of the turntable at the 60° position?
33.13 Angles Measured with the Measuring Machine, Tool Angles, and Chamfers
With a coordinate measuring machine (CMM), the angle is not measured—it is calculated. The machine probes several points on each surface, determines the plane or line that best approximates them, and calculates the angle between their directions. This method is used for angles between distant faces, between a hole and a face, or on workpieces that cannot be placed on a sine bar. The machine’s operation and its probing strategies are described in Chapter 37.
On a tilted plane, the CMM probes two points in the XY plane: P₁(12,000; 3,500) and P₂(42,000; 20,820), while the reference face is parallel to the X-axis. What is the angle of the side?
Tool Angles
The rake, cutting, and setting angles of a tool (Chapter 24) are checked using a tool protractor—a small set square with a graduated sector that rests on the base of the shank—or with a profile projector or optical presetters. A precise workshop method uses a lever-type dial indicator: the tool is placed on a flat surface, the indicator is lowered along the side of the tool, and the horizontal displacement of the tip is read for a known vertical travel.
The lever-type depth gauge moves down 5 mm along the main flank of a tool, and its reading changes by 0.61 mm. What is the tool's rake angle?
The Size of the Chamfers
A chamfer has two specifications: the width (or length) and the angle. The most common tools are:
- the hole chamfer gauge: a 90° (or 60°, 120°) conical probe that fits into the chamfer and directly reads the chamfer diameter on its face;
- the profile projector and workshop microscopes, with a rotating reticle graduated in degrees and minutes: the width, height, and angle of the chamfer are measured at 10x or 20x magnification;
- Snap-action gauges and 45° chamfer templates, for quick inspection during production.
On the projector, an external chamfer with the drawing dimensions “1.5 × 30°” measures 1.48 mm in length and 0.85 mm in height. What is its angle? A Ø10 hole with a 90° chamfer measures 12.4 mm in diameter on the chamfer gauge: how wide is the chamfer?
33.14 Common Errors in Angle Measurement
Many errors are common to all measurements (Chapter 31): temperature, dirt, parallax, and measurement force. Some, however, are specific to angles.
| Error | Reason | Remedy |
|---|---|---|
| Supplementary or Complementary Angle | Read the angle between the parts of the instrument, not the angle shown on the drawing | Make a sketch before reading; check visually to see if the angle is acute or obtuse. |
| Wrong half of the vernier scale | Look for the intersection on the opposite side from where the degrees increase. | Check that the reading + line · 1°55′ equals one full degree |
| Tool not perpendicular to the edge | The blade or base is at an angle to the corner edge: the angle measured “in perspective” is larger. | Keep the instrument's surface perpendicular to the edge |
| Zero on the level | The vial is not parallel to the base. | Inversion method (Example 33.6) |
| Dirty or loose blocks | A thin film of oil or a droplet just a few µm thick changes H | clean, secure, check the stack on the surface |
| Chin-up bar used at an angle greater than 45° | The breast changes little: H errors have a significant impact on the angle | Turn the workpiece over and measure the complement |
| Off-center controlled cone | The tip of the comparator is not aligned with the axis. | Center the tip (find the point where the reading reverses) |
| A burr or sharp edge under the square | The base does not rest on the surface | Deburr the workpiece, clean the work surface |
| A straight line mistaken for an angle | The face is curved: the angle depends on where the instrument rests. | First, check the flatness (Chapter 34) |
For the sine bar, it is useful to know how much an error on the blocks affects the result. Deriving H = L · sin α, we find dα = dH / (L · cos α): the angular error increases as 1/cos α, that is, slowly up to 45° and very rapidly near 90°.
100 mm sine bar: What angular error results in an error of 1 µm on the stack at 10°, 45°, 60°, and 80°? And what about a 5 µm misalignment in Example 33.8 (22°30′)?
33.15 The Formulas in This Chapter
| What Are You Looking For? | Formula |
|---|---|
| Small angle as a slope | e = L · tan θ ≈ L · θrad · 1″ = 4,848 · 10−6 rad |
| Out of sync with the sliver of light | θ ≈ f / h |
| Angular vernier scale | a = p / 12 = 5′ · reading = degrees + line · 5′ |
| Level | i = n · S · e = i · L · R = p / (S/1000) |
| Reversing the spirit level | i = (r1 − r2) / 2 · error = (r1 + r2) / 2 |
| C-bar (Chapter 6) | H = L · sin α · error ≈ Δ / l |
| Sensitivity of the sine bar | dα = dH / (L · cos α) |
| Outer cone with two rollers | tan(α/2) = (M1 − M2) / (2H) · D = M1 − dr · (1 + cot(45° + α/4)) |
| Inner cone with two balls | sin(α/2) = (R2 − R1) / ((h1 − h2) + (R1 − R2)) |
| Axial Position in the Conical Gauge | ΔD = C · Δz |
| Cone with Z-axis comparator | C = 2 · Δr / Δz · tan(α/2) = Δr / Δz |
| Indirect Division | nm = 40 / N · nm = β / 9° |
| Autocollimator | s = f · tan 2θ ≈ 2 · f · θ · Δh = b · θ |
33.16 Exercises
Try to solve them on your own, using a calculator, before looking at the solution. In the first three, the degrees increase as you go to the right.
Solution
The zero mark on the vernier scale is between 8° and 9°: 8°. On the right, it aligns with the third line (where “15” is marked): 3 × 5′ = 15′. Reading: 8°15′. Verification: 3 × 1°55′ = 5°45′ and 8°15′ + 5°45′ = 14°00′. The alignment visible on the left (the 45′ line) does not count.
Solution
Zero is between 63° and 64°: 63°. On the right, it coincides with the tenth line (the first after 45): 10 × 5′ = 50′. Reading: 63°50′. Verification: 10 × 1°55′ = 19°10′ and 63°50′ + 19°10′ = 83°00′ (on the 0-90-0 scale, the line coincides with 83).
Solution
Zero between 29° and 30°: 29°. The first line to the right of zero corresponds to: 5′. Reading: 29°05′ (verification: 29°05′ + 1°55′ = 31°00′). The obtuse angle between the faces is 180° − 29°05′ = 179°60′ − 29°05′ = 150°55′.
Solution
θ = 0.01 / 200 = 0.00005 rad = 0.00005 / 4.848 × 10−6 = 10.3″; with a slope of 0.05 mm/m.
Solution
i = 4 × 0.05 = 0.2 mm/m; e = 0.2 × 1.2 = 0.24 mm; 4 × 10.31″ = 41.3″.
Solution
18°20′ = 18.3333°; H = 100 · sin 18.3333° = 100 · 0.314545 = 31.454 mm; 1.004 + 1.45 + 4 + 25 = 31.454 mm ✓.
Solution
H = 200 · sin 34° = 200 · 0.559193 = 111.839 mm = 1.009 + 1.33 + 9.5 + 100 ✓. Second case: sin α = 0.42262 → α = 25.0001° ≈ 25°00′00″.
Solution
tan(α/2) = (48.62 − 45.98) / (2 × 25) = 2.64 / 50 = 0.0528 → α/2 = 3.0224° = 3°1′21″.
Solution
sin(α/2) = (15 − 10) / ((36.20 − 12.50) + (10 − 15)) = 5 / (23.70 − 5) = 5 / 18.70 = 0.26738 → α/2 = 15.508° = 15°30′30″.
Solution
ΔD = 0.9 / 20.020 = 0.045 mm: The seat is 0.045 mm smaller than the reference diameter.
Solution
36: 40/36 = 1 + 1/9 = 1 revolution and 2 holes on the 18-hole rim. 52: 40/52 = 10/13 = 30/39 → 30 holes on the 39-hole rim. 7°40′ = 7.6667°; 7.6667 / 9 = 0.85185 = 23/27 → 23 holes on the 27-hole rim (verification: 23/27 · 9° = 7.6667° = 7°40′).
Solution
θ = s / (2f) = 0,0233 / 800 = 2,9125 · 10−5 rad = 6.0″; Δh = 100 × 2.9125 × 10−5 = 0.0029 mm ≈ 2.9 µm.
Solution
tan α = 0.44 / 4 = 0.11 → α = 6.277° = 6°16′38″.