Pneumatics
Compressed air powers collets, clamps, cylinders, machine tool doors, and blowers in nearly every workshop. It’s inexpensive to install, clean, and safe, but producing it is costly, and every leak shows up on the bill. In this chapter, we’ll start with the physics of air (absolute and relative pressure, Boyle’s law), trace the air’s path from the compressor to the cylinder, learn how to calculate forces and consumption, read valve symbols, and draw circuits—from a single-cylinder control system to sequences involving two cylinders using the cascade method.
42.1 Compressed Air: Advantages and Limitations
Pneumatics uses compressed air to transmit energy and control signals. Air is drawn from the atmosphere, compressed by a compressor, and conveyed through tubing to the machines, where it drives the actuators (cylinders, motors, collets), which are controlled by valves. After doing its work, it returns to the atmosphere: a return line is not needed, unlike with hydraulic oil (Chapter 43).
In the workshop, pneumatic systems are everywhere: clamping workpieces in vises, changing tools and cleaning the spindles on machining centers, the automatic cabin door, the bar feeder, blow guns, screwdrivers, and assembly lines.
| Advantages | Limitations |
|---|---|
| Air is everywhere and costs nothing; the exhaust goes into the environment | It's expensive to produce: a compressor converts only a small portion of the electrical energy it consumes into useful work |
| Fast movements (even exceeding 1 m/s) and simple, cost-effective components | Modest forces: at 6 bar, a Ø100 cylinder produces less than 5 kN |
| No risk of fire or electric shock; it can be used in damp or dusty environments | Air is compressible: speed is not very consistent under varying loads, making precise positioning difficult |
| A cylinder blocked by the load does not break; it stops and waits | Exhaust noise (mufflers are needed) and condensation that needs to be removed |
| It can be stored in the tank and maintain pressure in the system | Leaks are invisible and don't make a mess, so they're often overlooked |
For this reason, pneumatics is the natural choice for rapid movements involving forces of up to a few thousand newtons, while for larger forces, hydraulics is used, and for precise positioning, electric motors are used (Chapter 48).
42.2 Pressure, Boyle's Law, and Free Air
Absolute, Relative, and Atmospheric Pressure
Pressure is a force divided by the area over which it acts. In Chapter 2, we looked at the units: in pneumatics, the bar is used (1 bar = 100,000 Pa = 0.1 MPa = 0.1 N/mm², approximately 14.5 psi). There is already pressure all around us—that of the air above us: atmospheric pressure, which averages 1.013 bar at sea level and decreases with increasing dimension.
Pressure can be measured using two different zero points:
- Absolute pressure starts from a perfect vacuum (absolute zero): it can never be negative;
- Relative pressure is based on atmospheric pressure: it is the reading shown on the pressure gauge. When mechanics say, “The system is at 6 bar,” they always mean 6 bar relative. Below atmospheric pressure, relative pressure is negative, and we refer to it as negative pressure or a vacuum, as in suction cups.
The system pressure gauge reads 6 bar; the vacuum gauge on a suction cup reads −0.8 bar. What are the absolute pressures?
Boyle's Law
If you compress a fixed amount of air enclosed in a cylinder while keeping the temperature constant, the volume decreases and the pressure increases in inverse proportion: halving the volume doubles the pressure. This is Boyle’s law (also known as Boyle and Mariotte’s law). Note: Absolute pressures are always used in the formula.
50 L of ambient air (1.013 bar absolute) is compressed to 6 bar relative at a constant temperature. What volume does it occupy?
In fact, as it is compressed, the air heats up (the bicycle pump gets hot); when it cools down in the tank and in the tubes, it returns to conditions close to those described by Boyle’s law. For practical calculations, Boyle’s law is sufficient.
Open-air and compression ratio
Air consumption and compressor flow rate are expressed in liters of free air (also called intake air or normal air): the volume that air occupies at atmospheric pressure. One liter of compressed air at 6 bar, if allowed to expand, becomes nearly 7 liters of free air. This conversion factor is called the compression ratio and is directly derived from Boyle’s law.
A 500-liter tank is pressurized to 8 bar. How many liters of free air does it contain? And how many liters can be used if the pressure is reduced to 6 bar?
With the compressor shut off, the system in Example 42.3 consumes 600 L/min of free air. How long can the tank alone maintain the system pressure above 6 bar?
42.3 Production: compressors, tank, dryer
The compressor draws in ambient air through a filter and brings it up to system pressure, usually between 7 and 10 bar, which is slightly higher than the operating pressure to compensate for pressure drops. There are two common types used in workshops.
- Piston (reciprocating): A piston driven by a connecting rod and crankshaft draws in air as it moves downward and compresses it as it moves upward; two automatic diaphragm valves allow air to enter and exit. For higher pressures, a two-stage system is used, with cooling between the two stages. It is economical and suitable for low or occasional usage; however, it is noisy and should be operated intermittently.
- Screw (rotary): two helical rotors—one with lobes and one with chambers—rotate while meshing with each other inside a housing; air enters from one side, is trapped between the lobes, and is compressed as it moves toward the discharge port. It operates in a continuous cycle with minimal vibration and is the standard choice for industrial systems; it often features an inverter-controlled motor (Chapter 45) to adjust the flow rate to demand.
After passing through the compressor, the air is hot and full of water vapor. The aftercooler cools it and causes a significant portion of the vapor to condense; the storage tank accumulates the air, dampens pulsations, collects additional condensate at the bottom, and allows the compressor to operate in cycles rather than continuously. The tank is always equipped with a calibrated safety valve, a pressure gauge, and a condensate drain, and it is a pressure vessel subject to periodic inspections.
The air coming out of the tank is still saturated with moisture: as soon as it cools in the pipes, the water condenses and reaches the valves and cylinders, where it washes away the grease, causes rust, and can freeze in the winter. That is why a dryer is installed:
- Refrigeration: cools the air to about 3 °C, causes the water to condense, and drains it; suitable for most indoor workshops;
- Adsorption-based: This method passes air through a material that traps water (alumina, molecular sieves), achieving dew points of −40 °C and lower; it is used for outdoor piping in winter, painting, and measuring instruments.
42.4 Air Distribution and Treatment
The loop network
The distribution network carries air from the compressor room to the machines. The best solution is a looped network: the main pipe runs all the way around the department and loops back, so that each outlet is supplied from two sides and the pressure drop remains low even at the farthest points. There are just a few practical rules for a well-designed network:
- The main pipe has a 1–2% slope (1 to 2 cm per meter) in the direction of flow, so that any condensate that forms flows toward the lowest points;
- Condensate drains—preferably automatic ones—should be installed at the lowest points;
- The outlets extend from the top of the main pipe, with a gooseneck bend, so that water flowing along the bottom does not enter the downspouts;
- Each downspout ends lower than the water supply line for the car, with a drain valve: the water collects there and not in the user's unit;
- Pipes should be sized generously: a 1-bar pressure drop in the system means the compressor has to operate at 1 bar higher, resulting in approximately 7% higher energy consumption (approximate value).
The FRL Treatment Group
Before reaching each machine, the air passes through the treatment unit, known as an FRL—an acronym for its three components:
- F, filter: circulates air through a glass (the centrifuge separates the water droplets) and passes it through a porous cartridge that traps impurities, typically ranging from 5 to 40 µm; the collected condensate is drained manually or via an automatic drain;
- R, pressure regulator: reduces the supply pressure to the level required by the machine and keeps it constant even if the supply pressure fluctuates; it is adjusted using the knob and read on the pressure gauge. The downstream pressure can only be equal to or lower than the upstream pressure;
- L, lubricator: sprays a very fine mist of oil into the air. Today, many components are lubricated for life, so the lubricator is no longer installed; but be careful: if a system has been lubricated, it must remain so at all times, because the oil has washed away the assembly grease.
The FRL unit is often equipped with a padlockable isolation valve, which shuts off the air supply and vents the system for maintenance, and a soft-start valve, which gradually fills the system at startup to prevent the cylinders from jarring suddenly.
42.5 Actuators: Cylinders
The cylinder It converts air pressure into force and linear motion. It is made of a reed (the tube, made of aluminum or steel), closed at both ends by two publications, with a piston sealed and connected to the stem, which exits the front end through a guide bushing and a scrape it off which keeps dirt out. The travel is the distance the rod travels from fully retracted to fully extended.
- Single-acting cylinder: Air enters through a single port and pushes the piston in one direction; a spring returns it. It uses half as much air, but the spring reduces the force and limits the travel (usually up to about 100 mm). It is used for small clamping applications, ejectors, and marking.
- Double-acting cylinder: two ports, one per chamber; air pushes the piston in both directions. It is the most commonly used cylinder: it provides force in both the forward and return travels and is capable of long travels.
At the end of its travel, the piston reaches speeds of up to 1 m/s and would slam into the cylinder head. The pneumatic shock absorber slows it down: over the last 15–30 mm, a sleeve on the piston rod enters a seal in the cylinder head and closes the main air outlet; the air remaining in the chamber can escape only through a small passage regulated by a screw; it compresses and acts as a cushion. It is adjusted by tightening the screw until the piston reaches the bottom without impact, but without bouncing. For large masses and high speeds, external hydraulic dampers are added.
The ring magnet in the piston is used by the magnetic sensors mounted outside the barrel, which signal the piston’s position without physical contact (paragraph 42.13). Standardized cylinders (ISO 15552 for bores from 32 to 320 mm, ISO 6432 for mini-cylinders from 8 to 25 mm) have the same mounting interfaces and overall dimensions across all manufacturers and can be interchanged without modifying the machine drawing.
42.6 Cylinder Force and Bore Selection
The air presses against the entire surface of the piston, so the force is equal to the pressure multiplied by the area. During the extension stroke (when the rod extends), the area is the entire surface area of the piston, with diameter D (the bore). During the pull stroke (when the rod retracts), the air presses against the circular ring around the rod: the area of the rod, with diameter d, must be subtracted from the area of the piston. Therefore, at the same pressure, a cylinder always exerts less force during the pull stroke than during the push stroke.
Relative pressure is used, not absolute pressure: on the other side of the piston, there is still atmospheric pressure (the exhaust chamber is open to the atmosphere), and the two atmospheric pressures cancel each other out.
Double-acting cylinder with a bore of 50 mm and a rod diameter of 20 mm, operated at 6 bar. Calculate the theoretical and actual forces with η = 0.9.
A single-acting cylinder with a diameter of 32 and operating at 6 bar has a spring that exerts a force of 40 N at the end of its travel. Given that η = 0.9, what force does it exert at the end of the travel?
Choosing the Bore Diameter
To select the cylinder, start by determining the required force, divide it by the efficiency and the pressure, and calculate the theoretical bore; then choose the next larger standard bore. It’s a good idea to leave a margin: system pressure can drop when many machines are drawing power at the same time, and a cylinder that also has to accelerate a load needs extra force.
| Bore D (mm) | Stem d (mm) | Area A (cm²) | Theoretical thrust (N) | Theoretical Traction (N) | Thrust with η = 0.85 (N) |
|---|---|---|---|---|---|
| 12 | 6 | 1,13 | 68 | 51 | 58 |
| 16 | 6 | 2,01 | 121 | 104 | 103 |
| 20 | 8 | 3,14 | 188 | 158 | 160 |
| 25 | 10 | 4,91 | 295 | 247 | 250 |
| 32 | 12 | 8,04 | 483 | 415 | 410 |
| 40 | 16 | 12,57 | 754 | 633 | 641 |
| 50 | 20 | 19,63 | 1178 | 990 | 1001 |
| 63 | 20 | 31,17 | 1870 | 1682 | 1590 |
| 80 | 25 | 50,27 | 3016 | 2721 | 2564 |
| 100 | 25 | 78,54 | 4712 | 4418 | 4006 |
| 125 | 32 | 122,72 | 7363 | 6881 | 6259 |
| 160 | 40 | 201,06 | 12 064 | 11 310 | 10 254 |
| 200 | 40 | 314,16 | 18 850 | 18 096 | 16 022 |
Table 42.1 · Standard bores and forces at 6 bar, calculated using F = p · A. The rods are those typical of the standard series (ISO 6432 up to 25, ISO 15552 from 32 onward): the exact values should always be taken from the manufacturer’s catalog.
A cylinder must push a workpiece with a force of 2000 N; the system provides 6 bar; efficiency is 0.85.
A clamping bracket must exert a force of 1500 N at 6 bar and with η = 0.85. Is a Ø63 cylinder with a Ø20 piston rod sufficient?
A Ø40 cylinder must apply a force of 500 N to a delicate workpiece—no more. To what value should the regulator be set? (η = 0.9)
42.7 Air Consumption
With each travel, the cylinder fills with air at operating pressure, and during the return travel, that air is discharged into the atmosphere. The consumption per cycle is therefore the volume of the filled chambers, multiplied by the compression ratio, to express it in liters of free air—that is, in the same unit as the compressor’s flow rate.
Cylinder Ø50, rod Ø20, travels 200 mm, 6 bar, 10 cycles per minute. Calculate the consumption per cycle and per minute in free air.
A single-acting ejector with a diameter of 32, travel of 50 mm, and a pressure of 6 bar operates at 30 cycles per minute.
A department has 4 cylinders, as in Example 42.10, 2 ejectors, as in Example 42.11, and a blow-off gun that consumes 200 L/min but is used, on average, for one-quarter of the time. Add 30% to account for losses and future expansion.
42.8 Speed, Control, and Other Actuators
The speed of the cylinder
The piston speed depends on how much air can enter one chamber and, above all, exit the other: on the pressure, the load, the valve flow rate, and the lengths and diameters of the tubes. Standard cylinders operate at speeds between approximately 0.1 and 1 m/s; below 0.05 m/s, the motion becomes jerky (the friction between the seals causes them to separate and reattach, a phenomenon known as stick-slip).
The Ø50 cylinder in Example 42.10 must travel 200 mm in the forward direction in 0.8 s. What is the free air flow rate that the valve must provide?
The adjustment: restricted exhaust
To slow down a cylinder, a unidirectional flow regulator is used: an adjustable orifice with a check valve connected in parallel. In one direction, the air flows freely through the check valve; in the other, it is forced to pass through the throttle. In double-acting cylinders, the exhaust is throttled: air enters freely into the driving chamber and exits, slowed down, through the exhaust chamber. Thus, the piston remains held between two cushions of pressurized air and moves smoothly even if the load changes. By throttling the intake, however, the piston moves in jerks; this is done only in single-acting cylinders and in a few special cases.
The regulators are mounted as close as possible to the cylinder, often screwed directly into its ports; to ensure a quick return, a quick-release valve is added to the cylinder port, which vents the air there without allowing it to flow all the way back to the valve. The complete diagram is shown in Figure 42.17.
Other Actuators (Overview)
- Rodless cylinders: The piston drives an external carriage through a slot using sealing strips or a magnetic coupling. For the same travel, they take up half the space and are suitable for travels measured in meters.
- Rotary actuators: vane-type or piston-type with rack and pinion; they provide limited rotation (90°, 180°, 360°) and are used to rotate workpieces, open valves, and tilt.
- Parallel or angular collets: two or three jaws driven by a piston, for manipulators and robots (Chapter 51).
- Suction cups and vacuum generators: The Venturi-effect generator directs compressed air through a nozzle that narrows; the air accelerates, the pressure drops, and it draws in air through the side port, creating a vacuum in the suction cup. It has no moving parts and is used for sheet metal, glass, and cardboard.
A Ø40 suction cup operates at a vacuum of −0.6 bar. Given a safety factor of 2 for vertical lifting, what is the maximum weight of the workpiece?
The peak load on the stem
A long, thin rod under thrust may bend sideways before breaking: this is the peak load discussed in Section 10.12. For pneumatic cylinders, this problem arises with long travels—over 500–1,000 mm—and articulated mounts. The verification is performed using Euler’s formula, with the rod fully extended, where the free length at the inflection point depends on the mountings.
A Ø100 cylinder with a Ø25 steel rod operates at 6 bar. It is articulated at both ends, and when the rod is fully extended, the free bending length is 1100 mm. With a safety factor of 4, will it hold up?
42.9 Distributor Valves
Distributor valves (or distributors) determine where the air goes: they open, close, and divert the flow between the connections. Inside, they have a spool or spool valve that moves between two or three positions. Drawings do not show the valve’s internal structure, but only its function, using a symbol in accordance with ISO 1219.
How to Read the Symbol
- Each square represents a valve position: two squares, two positions;
- Inside each square, the arrows indicate open passages and the direction of airflow; the T-shaped symbol indicates a closed passage;
- The tubes are attached to the square representing the rest position (the position the valve is in when not actuated): to visualize the other position, slide the symbol until the other square takes the place of the first one;
- The moves are the valid attacks, which are counted on the rest square;
- On either side are the controls: the control shown next to a square moves the valve to that position.
A valve is designated by two numbers: routes / locations. A 5/2 has 5 lines and 2 positions. The bindings are numbered: 1 nutrition, 2 e 4 uses, 3 e 5 outlets; the control commands correspond to the numbers of the two connections they link (14 connects 1 to 4, 12 connects 1 to 2, 10 closes 1). On older diagrams, you’ll also find the letters P (supply), A and B (outputs), and R and S (drains).
The Commands
Controls are divided into muscular (button, lever, pedal: operated by the operator), mechanical (taster, roller, unidirectional roller: operated by a part of the machine, such as a cam on the stem), spring-loaded (return the valve to its rest position), pneumatic (an air signal moves the spool), and electric (a solenoid, i.e., a coil that attracts an iron core). In larger solenoid valves, the coil does not move the spool directly: it opens a small pilot valve that sends air to move it (servo-piloted control).
A valve with one control signal and a spring is monostable: once the control signal ends, it returns to its rest position. A valve with two opposing control signals and no spring is bistable: it remains in the last position it was commanded to be in even after the signal ends—that is, it acts as a memory.
The Most Commonly Used Valves
- 2/2: Opens or closes a passage, like a faucet;
- 3/2 NC (normally closed): in the closed position, port 2 is connected to the exhaust port 3 and the supply port 1 is closed; when actuated, it directs air from port 1 to port 2. This is the valve used for single-acting cylinders and signals (buttons, limit switches);
- 3/2 NO (normally open): the opposite—it allows air to flow when not activated and blocks it when activated;
- 4/2 and 5/2: These are controlled by double-acting cylinders, which send air to one chamber while venting the other. The 5/2 has two separate exhaust ports, so the exhaust flow rate can be adjusted (using adjustable silencers), and the ports are larger; it is the most commonly used type.
The 5/3 valves have a third central position, which the spool moves to when no control signal is active (it is usually centered by two springs). The central position determines what happens to the cylinder when the control signal is removed, for example, in an emergency:
- closed centers: all ports are closed; the cylinder stops where it is (but the compressible air allows it to give slightly under load, and leaks cause it to slip over time);
- open-center pressure systems: fluid is supplied to both chambers; in a single-rod cylinder, the thrust prevails and the rod extends smoothly;
- Exhaust ports: Both chambers are vented; the cylinder can be moved by hand without air pressure; this is useful for freeing a workpiece or an operator.
42.10 Other Valves
- Check valve: allows air to flow in one direction and blocks it in the other; in the symbol, the ball rests against the V-shaped seat when air pushes in the wrong direction.
- Selector valve (logical function OR, "or"): It has two inputs and one output; air comes out of the output if it enters through one of the inputs o On the other hand, the inner ball seals the inlet without pressure, so air does not escape from the button when it is not pressed.
- Simultaneity valve (AND function, “and”): Air is discharged only if it is supplied from both inputs.
- One-way flow regulator: adjustable orifice valve with check valve, for regulating flow in one direction only.
- Quick-release valve: mounted on the cylinder connection; when the control valve opens, it creates a large passage to the atmosphere; the cylinder empties immediately, and the return is faster.
- Pneumatic timer (overview): A signal fills a small reservoir through a restrictor; when the pressure in the reservoir has risen sufficiently, it actuates a 3/2-way valve. The delay is adjusted using the restrictor, ranging from fractions of a second to a few tens of seconds. Today, delays are almost always implemented using a PLC (Chapter 49).
42.11 Basic Circuits
In pneumatic diagrams, components are arranged from bottom to top, following the flow of energy: the power supply at the bottom, the valves that provide signals (buttons, limit switches) above, then the power valves, and the actuators at the top. Components are drawn in their rest position; control lines are drawn as dashed lines.
Direct and Indirect Control
In direct control, the operator operates the valve that sends air to the cylinder: simple, but the button valve must be as large as the cylinder requires and be located close to it. In indirect control, the button is a small signal valve that controls a larger power valve mounted near the cylinder: the button can be located farther away, on the panel, connected by thin tubing. All real machines use indirect control.
The double-acting cylinder is controlled by a 5/2-way valve. With a monostable 5/2-way button valve, the piston rod extends only as long as the button is held down. With a bistable 5/2-way valve controlled by two buttons, S1 extends the piston rod and S2 retracts it, and the valve retains the last command even when the buttons are released. Figure 42.17 on the right also shows the two flow regulators installed to restrict the exhaust flow.
Two-point control and two-hand control
To control a cylinder from two different locations, install two buttons and an OR selector valve: pressing either one is sufficient. To ensure that the operator keeps both hands away from the hazardous area, a simultaneous-action valve (AND) is used: the cylinder activates only if both buttons are pressed at the same time. Note: This is only the basic principle; a true two-hand safety control system must also verify that the buttons are pressed within half a second of each other and that they are released before a new cycle begins, and this is achieved using certified modules (Chapter 51).
Automatic return, semi-automatic cycle, and automatic cycle
To allow the rod to retract automatically when it reaches the end of its stroke, a limit valve is used: a 3/2 NC roller valve, mounted where the cam contacts the rod. The positions are designated by the lowercase letter corresponding to the cylinder: a0 is the end-of-stroke position with the piston rod retracted, and a1 is the end-of-stroke position with the piston rod extended. In the semi-automatic cycle, the operator presses the start button; the piston rod extends, touches a1—which activates pin 12 of the bistable relay—and the piston rod retracts: one cycle per press of the button.
In the automatic cycle, the cycle start is triggered by a lever valve with a hold mechanism (it remains actuated) connected in series with the a0 limit switch: when the stem has retracted and touches a0, if the gear is engaged, a new cycle begins, and so on until the lever is moved. The two valves in series perform an AND function without the need for a simultaneity valve.
42.12 Two-cylinder sequences
The Stride-Step Diagram
When there is more than one cylinder, the cycle is described using the following sequence: the cylinder letter followed by + (rod extends) or − (rod retracts). For example, A+ B+ A− B− means: A extends, then B extends, then A retracts, then B retracts. The stroke-stroke diagram illustrates this: the horizontal axis shows the travels of the cycle, and the vertical axis shows the position of each cylinder (0 = retracted, 1 = extended).
The sequence A+ B+ A− B−: no blocking signal
Each movement is controlled by the limit switch that signals the end of the previous movement: A+ at startup and b0 (in series), B+ with a1, A− with b1, B− with a0. Referring to the diagram, verify that when a signal commands a movement, the opposite signal on the same valve has already disappeared: for example, when b1 commands A−, the A+ signal (start and b0) is no longer present, because B is off. The sequence operates using the direct circuit shown in Figure 42.21.
Using the same method, the sequence A+ B+ B− A− would be controlled as follows: A+ at startup, B+ with a1, B− with b1, A− with b0. Let’s check step by step to ensure that the two commands do not arrive simultaneously at the two bistable circuits.
A signal is blocking when it remains active even during the stroke in which the same valve is supposed to move in the opposite direction. To spot this, simply look at the stroke-cycle diagram: a cylinder that makes two consecutive movements (such as B+ and immediately B−) without another cylinder moving in between almost always indicates a problem. There are three solutions:
- unidirectional roller limit switch: the roller engages only when the piston rod moves in one direction and produces a brief pulse instead of a continuous signal; it works, but the limit switch must be mounted slightly before the end of the travel and no longer indicates with certainty where the cylinder is located;
- memory valve: a 3/2 or 5/2 bistable valve that supplies power to the latching limit switch only during the part of the cycle when it is needed, and “turns it off” during the rest of the cycle;
- Cascade method: This is the systematic way to use memory valves, and it works for any sequence.
The Waterfall Method
The sequence is divided into groups so that each letter appears only once in each group: A+ B+ / B− A− forms two groups, I and II. Each group has its own air line, and only one line is pressurized at a time; the memory valves—which number one less than the number of groups (in this case, a single 5/2-way bistable valve)—switch them. The limit switches are powered by their respective group’s line, so a limit switch that remains activated when the cycle is stopped does not cause any issues when its line is de-energized. The rules:
- The first move of each group is directed directly by the group's line (Line I → A+, Line II → B−);
- Subsequent movements within the same group are controlled by the limit switch of the previous movement, which is powered by that line (a1, from line I, controls B+);
- The last limit switch in a group does not control a cylinder but rather the memory, which is passed on to the next group (b1 switches to II; b0, from line II, then controls A−);
- The last limit switch of the cycle (a0), connected in series with the cycle start switch, resets the memory to Group I and restarts the cycle.
Let’s follow the cycle. At rest, line II is energized (the memory is at rest on 2): b0 is active but drives A−, which has already been done, so it doesn’t cause any issues. The start button is pressed: with a0 activated, the memory switches to I. Line I controls A+; A turns on and activates a1, which (powered by I) controls B+; B turns on and activates b1, which switches the memory to II. Now line I is off: a1 no longer controls anything, and the block from step 3 has disappeared. Line II controls B−; B returns to its normal state and activates b0, which controls A−; A returns to its normal state and activates a0, ready for the next cycle. The trade-off of this cascade is a slight delay at each group change, because the line must fill up; with many groups, series-connected solenoids slow down the cycle, and for more than three or four cylinders, an electropneumatic system with a PLC is preferred.
42.13 Electropneumatics
In modern machines, the power system remains pneumatic (cylinders and valves), while the control system is electrical: signals are sent from sensors and electrical buttons and are transmitted to the solenoid coils via relays or, almost always, a PLC.
- Monostable solenoid valves (one coil and a spring) return to their rest position when power is cut off; bistable solenoid valves (two coils) remain in their current position. They typically operate at 24 V DC and are mounted in a bank on a single base—the valve island—connected to the PLC via a single cable or a fieldbus network.
- Magnetic sensors are mounted in the barrel groove and detect the piston’s magnet through the wall: they are either reed switches (a blade that closes when near the magnet) or electronic Hall-effect or magnetoresistive sensors, with no moving parts. They replace roller limit switches and do not require cams. We will discuss them in Chapter 47.
- The sequence is written in the PLC program (Chapter 49), where the interlock signals are handled using program registers instead of additional valves.
The electrical diagram in Figure 42.23 corresponds to the pneumatic diagram on the left side of Figure 42.19: S1 and 1B1, connected in series, form an AND gate between the start signal and the retracted spool; 1B2 acts as the limit switch a1. The designations follow the standard: 1A is the cylinder, 1B1 and 1B2 are its sensors, 1Y1 and 1Y2 are the solenoid valve coils, and S1 is the button.
42.14 Safety, Cost Savings, and Maintenance
Safety
- Before working on a system, close the isolation valve and bleed the air: a cylinder with trapped air (for example, one with a 5/3 closed-center valve) can move suddenly when a hose is disconnected.
- A hose that comes loose under pressure can whip around and cause injury: Use appropriate fillets and, for large hoses, safety clamps.
- Never point the air gun at people or at the skin; use safety nozzles that limit the outlet pressure when cleaning workpieces. Blown-off chips can fly into your eyes: always wear safety glasses.
- Valve exhausts always have a muffler: a noisy workshop is a workshop that’s dangerous to your hearing.
- At startup, the soft-start valve prevents the cylinders from activating all at once; if there is no air, the machine must move to a safe position (Chapter 51).
Air Leaks and Energy Savings
Compressed air is the most expensive form of energy in a workshop: to produce one cubic meter of free air at 7 bar, a good compressor consumes about 0.10–0.12 kWh of electricity, and almost all of it is converted into heat. In a poorly maintained system, leaks (loose fillets, cut hoses, worn gaskets, left-open air guns) can easily account for 20–30% of output. You can’t see a leak—you hear it when the machines are shut down, in the silence at the end of the shift.
From a 1-mm hole at 6 bar, approximately 60 L/min of free air escapes (approximate value: depends on the shape of the hole). The network remains pressurized 16 hours a day for 250 days. At 0.12 kWh per cubic meter and an energy cost of 0.25 €/kWh, how much does the leak cost per year? (All figures are approximate and chosen for illustrative purposes.)
The rules for saving money are simple: locate and repair leaks (even using ultrasonic detectors), operate at the lowest pressure necessary, shut off the air supply to idle machines using a valve controlled from the control panel, use cylinders of the correct size, avoid continuous air discharge, and recover heat from the compressor to heat water or the workshop.
Maintenance
| Component | What do you do? | When (indicative) |
|---|---|---|
| Tank and Automatic Drains | Check that condensation is draining; empty it by hand if necessary | Every day or every week |
| FRL Group Filters | Drain the glass; replace the cartridge when the pressure drop increases | Every week / every 6–12 months |
| Lubricator (if any) | Top off with the oil specified by the manufacturer; check for leaks | Every week |
| Compressor | Air filter, oil, separator, belts, temperature | According to the working hours listed in the manual |
| Dryer | Clean the condenser; check the dew point | Every month |
| Netting and Fillets | Leak Detection When Machinery Is Shut Down | Every 3–6 months |
| Cylinders | Clean the stem, check the stem scraper, clearances, and shock absorbers; replace the seals if there is a leak | Machine Maintenance |
| Mufflers | Replace any clogged ones, as they slow down the cylinders | When a movement slows down |
42.15 The Formulas in This Chapter
| What | Formula |
|---|---|
| Absolute pressure | pass = prel + 1.013 bar |
| Boyle's Law | p1 · V1 = p2 · V2 (absolute pressures) |
| Compression Ratio | r = (prel + 1.013) / 1.013; Vfree = Vcompressed · r |
| Usable air volume of a tank | Vfree = Vtank · (pmax − pmin) / 1.013 |
| Theoretical thrust force | F = p · A ; A = π · D² / 4 |
| Theoretical tensile force | F = p · (A − a) ; a = π · d² / 4 |
| Real force | Freale = η · Ftheoretical (η ≈ 0.85–0.9); single-effect: F = η · p · A − Fspring |
| Required bore diameter | D = √(4 · F / (π · p · η)) |
| Consumption per cycle (double-acting) | Qcycle = (A + A − a) · c · r |
| Per-minute usage | Q = Qcycle · n |
| Flow rate at a given velocity | Q = A · v · r |
| Force of a suction cup | F = Δp · π · d² / 4 |
42.16 Exercises
Unless otherwise specified, atmospheric pressure is 1.013 bar and the system operates at 6 bar.
Solution
pass = 4.5 + 1.013 = 5.513 bar. In psi: 4.5 × 14.50 = 65.3 psi.
Solution
p2 = 1.013 × 20 / 5 = 4.052 bar absolute, that is, 4.052 − 1.013 = 3.039 bar relative.
Solution
r = 9.013 / 1.013 = 8.897; free air volume = 2 × 8.897 = 17.8 L.
Solution
Available air = 270 · (9 − 7) / 1.013 = 533 L; time = 533 / 400 = 1.33 min, approximately 80 s.
Solution
A = π · 63² / 4 = 3117.2 mm²; thrust = 0.6 · 3117.2 = 1870 N. A − a = 3117.2 − 314.2 = 2803.0 mm²; tensile force = 0.6 · 2803.0 = 1682 N.
Solution
A = 1256.6 mm², a = 201.1 mm². Compressive force = 0.85 · 0.6 · 1256.6 = 641 N; tensile force = 0.85 · 0.6 · (1256.6 − 201.1) = 538 N.
Solution
D = √(4 · 3500 / (3.1416 · 0.6 · 0.85)) = 93.5 mm: we choose Ø100, which gives 0.85 · 0.6 · 7854 = 4006 N.
Solution
A = 490.9 mm²; F = 0.9 × 0.6 × 490.9 − 25 = 265.1 − 25 = 240 N.
Solution
Volume per cycle = (1256.6 + 1055.6) × 150 = 346,832 mm³ = 0.3468 L; for 6.923 = 2.40 L of free air per cycle; for 12 cycles = 28.8 L/min.
Solution
v = 100 / 0.5 = 200 mm/s; A · v = 804.2 · 200 = 160,850 mm³/s = 0.161 L/s; multiplied by 6.923 = 1.11 L/s = 66.8 L/min.
Solution
Required force = 2 · 9.81 · 2 = 39.24 N; area = 39.24 / 0.06 = 654 mm²; d = √(4 × 654 / 3.1416) = 28.9 mm: Choose a suction cup with a diameter of 30 mm or larger.
Solution
i = 20 / 4 = 5 mm, λ = 800 / 5 = 160 (Euler's formula applies); I = π · 20⁴ / 64 = 7854 mm⁴; Fcr = 3.1416² · 210,000 · 7,854 / 800² = 25,435 N; Fam = 6,359 N, which is 3,016 N greater than the thrust: that’s fine.
Solution
Left position (command 14): 1 with 4, 2 with 3, 5 closed. Center: all five attacks closed. Right position (command 12): 1 with 2, 4 with 5, 3 closed.
Solution
Groups: I = A+ B+; II = B− C+; III = C− A− (each letter appears only once in each group). Three groups, so 3 − 1 = 2 memory valves.
Solution
Air loss = 3 × 60 × 60 × 2,000 = 21,600,000 L = 21,600 m³; energy = 21,600 × 0.12 = 2,592 kWh; cost = 2,592 × 0.25 = 648 €.