Chapter 42

Pneumatics

Compressed air powers collets, clamps, cylinders, machine tool doors, and blowers in nearly every workshop. It’s inexpensive to install, clean, and safe, but producing it is costly, and every leak shows up on the bill. In this chapter, we’ll start with the physics of air (absolute and relative pressure, Boyle’s law), trace the air’s path from the compressor to the cylinder, learn how to calculate forces and consumption, read valve symbols, and draw circuits—from a single-cylinder control system to sequences involving two cylinders using the cascade method.

42.1 Compressed Air: Advantages and Limitations

Pneumatics uses compressed air to transmit energy and control signals. Air is drawn from the atmosphere, compressed by a compressor, and conveyed through tubing to the machines, where it drives the actuators (cylinders, motors, collets), which are controlled by valves. After doing its work, it returns to the atmosphere: a return line is not needed, unlike with hydraulic oil (Chapter 43).

In the workshop, pneumatic systems are everywhere: clamping workpieces in vises, changing tools and cleaning the spindles on machining centers, the automatic cabin door, the bar feeder, blow guns, screwdrivers, and assembly lines.

AdvantagesLimitations
Air is everywhere and costs nothing; the exhaust goes into the environmentIt's expensive to produce: a compressor converts only a small portion of the electrical energy it consumes into useful work
Fast movements (even exceeding 1 m/s) and simple, cost-effective componentsModest forces: at 6 bar, a Ø100 cylinder produces less than 5 kN
No risk of fire or electric shock; it can be used in damp or dusty environmentsAir is compressible: speed is not very consistent under varying loads, making precise positioning difficult
A cylinder blocked by the load does not break; it stops and waitsExhaust noise (mufflers are needed) and condensation that needs to be removed
It can be stored in the tank and maintain pressure in the systemLeaks are invisible and don't make a mess, so they're often overlooked

For this reason, pneumatics is the natural choice for rapid movements involving forces of up to a few thousand newtons, while for larger forces, hydraulics is used, and for precise positioning, electric motors are used (Chapter 48).

42.2 Pressure, Boyle's Law, and Free Air

Absolute, Relative, and Atmospheric Pressure

Pressure is a force divided by the area over which it acts. In Chapter 2, we looked at the units: in pneumatics, the bar is used (1 bar = 100,000 Pa = 0.1 MPa = 0.1 N/mm², approximately 14.5 psi). There is already pressure all around us—that of the air above us: atmospheric pressure, which averages 1.013 bar at sea level and decreases with increasing dimension.

Pressure can be measured using two different zero points:

  • Absolute pressure starts from a perfect vacuum (absolute zero): it can never be negative;
  • Relative pressure is based on atmospheric pressure: it is the reading shown on the pressure gauge. When mechanics say, “The system is at 6 bar,” they always mean 6 bar relative. Below atmospheric pressure, relative pressure is negative, and we refer to it as negative pressure or a vacuum, as in suction cups.
Absolute and Relative Pressure
pass = prel + patm patm ≈ 1.013 bar
pass absolute pressure in bar · prel relative pressure (on the pressure gauge) in bar · pATM Atmospheric pressure in bar. In workshop calculations, many people round to 1 bar; here we use 1.013.
0123456780123456−1absolute barrelative barabsoluterelativeShop pressure: 6 bar relative= 7.013 bar absoluteatmospheric pressure (sea level)1.013 bar absolute = 0 bar relativesuction cup (blue line): −0.8 bar relative = 0.213 bar absoluteAbsolute zero (thick line): perfect vacuum; pressure cannot drop below this pointThe manometer measures the differencerelative to the surrounding air: it indicates therelative pressure.
Figure 42.1 · The two pressure scales. Relative pressure is measured relative to atmospheric pressure, while absolute pressure is measured relative to a perfect vacuum.
Example 42.1 · From Relative to Absolute

The system pressure gauge reads 6 bar; the vacuum gauge on a suction cup reads −0.8 bar. What are the absolute pressures?

network: pressure = 6 + 1.013 = 7.013 bar
suction cup: pressure = −0.8 + 1.013 = 0.213 bar
7.013 bar and 0.213 bar absolute: the suction cup operates at a vacuum of approximately 80%

Boyle's Law

If you compress a fixed amount of air enclosed in a cylinder while keeping the temperature constant, the volume decreases and the pressure increases in inverse proportion: halving the volume doubles the pressure. This is Boyle’s law (also known as Boyle and Mariotte’s law). Note: Absolute pressures are always used in the formula.

Boyle's Law (constant temperature)
p1 · V1 = p2 · V2 = constant V2 = p1 · V1p2
p1, p2: absolute pressures before and after, in bar · V1, V2: volumes before and after, in liters (or in any unit, provided it is the same)
V = 50 Lp = 1.013 bar abs.V = 25 Lp = 2.026 bar abs.V = 7.22 Lp = 7.013 bar abs.V (L)absolute pressure (bar)7.22 L · 7.013 bar25 L · 2.026 bar50 L · 1.013 barp · V = 50.65 bar · L at all points
Figure 42.2 · The same amount of compressed air in increasingly smaller volumes: the product p · V remains constant, and the curve is a hyperbola.
Example 42.2 · Compress 50 liters of air to 6 bar

50 L of ambient air (1.013 bar absolute) is compressed to 6 bar relative at a constant temperature. What volume does it occupy?

p2 = 6 + 1.013 = 7.013 bar (absolute)
V2 = 1,013 · 507,013 = 50,657,013 = 7,22 L
7.22 L: At 6 bar, the air occupies about one-seventh of the volume it had outside

In fact, as it is compressed, the air heats up (the bicycle pump gets hot); when it cools down in the tank and in the tubes, it returns to conditions close to those described by Boyle’s law. For practical calculations, Boyle’s law is sufficient.

Open-air and compression ratio

Air consumption and compressor flow rate are expressed in liters of free air (also called intake air or normal air): the volume that air occupies at atmospheric pressure. One liter of compressed air at 6 bar, if allowed to expand, becomes nearly 7 liters of free air. This conversion factor is called the compression ratio and is directly derived from Boyle’s law.

Compression Ratio and Free Air Volume
r = prel + 1,0131,013 Vfree = Vtablet · r
r compression ratio (pure number) · prel relative working pressure in bar · Vcompressa volume occupied by the air at working pressure · Vlibera volume of the same air at atmospheric pressure. At 6 bar, r = 6.923; at 7 bar, r = 7.910; at 8 bar, r = 8.897.
Example 42.3 · How Much Air Is in a Tank?

A 500-liter tank is pressurized to 8 bar. How many liters of free air does it contain? And how many liters can be used if the pressure is reduced to 6 bar?

r = (8 + 1,013) / 1,013 = 8,897
volume of free air = 500 × 8.897 = 4,449 L
Operating range: 8 to 6 bar = 500 · 8 − 61,013 = 987 L
About 4,450 L in total, but only 987 L can be used without dropping below 6 bar
Example 42.4 · How long does the tank's reserve last?

With the compressor shut off, the system in Example 42.3 consumes 600 L/min of free air. How long can the tank alone maintain the system pressure above 6 bar?

t = 987 / 600 = 1.65 min ≈ 1 min and 39 s
Just over a minute and a half: the tank is designed to handle peaks in demand and give the compressor a rest, not to replace it

42.3 Production: compressors, tank, dryer

The compressor draws in ambient air through a filter and brings it up to system pressure, usually between 7 and 10 bar, which is slightly higher than the operating pressure to compensate for pressure drops. There are two common types used in workshops.

  • Piston (reciprocating): A piston driven by a connecting rod and crankshaft draws in air as it moves downward and compresses it as it moves upward; two automatic diaphragm valves allow air to enter and exit. For higher pressures, a two-stage system is used, with cooling between the two stages. It is economical and suitable for low or occasional usage; however, it is noisy and should be operated intermittently.
  • Screw (rotary): two helical rotors—one with lobes and one with chambers—rotate while meshing with each other inside a housing; air enters from one side, is trapped between the lobes, and is compressed as it moves toward the discharge port. It operates in a continuous cycle with minimal vibration and is the standard choice for industrial systems; it often features an inverter-controlled motor (Chapter 45) to adjust the flow rate to demand.
suctiondischargeautomatic valvespistonconnecting rodcrankshaftcompressed airPiston compressorintakedischargeMale rotor (lobes)female rotor (chambers)Screw compressor
Figure 42.3 · On the left is a piston compressor: air enters through the intake valve and exits in a compressed state through the discharge valve. On the right is a screw compressor: air is compressed between the lobes of the two rotors.

After passing through the compressor, the air is hot and full of water vapor. The aftercooler cools it and causes a significant portion of the vapor to condense; the storage tank accumulates the air, dampens pulsations, collects additional condensate at the bottom, and allows the compressor to operate in cycles rather than continuously. The tank is always equipped with a calibrated safety valve, a pressure gauge, and a condensate drain, and it is a pressure vessel subject to periodic inspections.

The air coming out of the tank is still saturated with moisture: as soon as it cools in the pipes, the water condenses and reaches the valves and cylinders, where it washes away the grease, causes rust, and can freeze in the winter. That is why a dryer is installed:

  • Refrigeration: cools the air to about 3 °C, causes the water to condense, and drains it; suitable for most indoor workshops;
  • Adsorption-based: This method passes air through a material that traps water (alumina, molecular sieves), achieving dew points of −40 °C and lower; it is used for outdoor piping in winter, painting, and measuring instruments.
❄filterintakecompressorcoolerfinaltankdryerfilterlinenetworksafety valvepressure gaugecondensate drainEach stage removes something from the air: dust, heat, water, oil.
Figure 42.4 · The compressor room: suction filter, compressor, aftercooler, tank with safety valve and condensate drain, dryer, and line filter.
💧
That's a lot of water. On a summer day, a compressor that produces a few hundred liters of free air per minute separates tens of liters of condensate per shift. It isn't clean water: it contains compressor oil and must be collected in a water-oil separator before being discharged, as required by environmental regulations.

42.4 Air Distribution and Treatment

The loop network

The distribution network carries air from the compressor room to the machines. The best solution is a looped network: the main pipe runs all the way around the department and loops back, so that each outlet is supplied from two sides and the pressure drop remains low even at the farthest points. There are just a few practical rules for a well-designed network:

  • The main pipe has a 1–2% slope (1 to 2 cm per meter) in the direction of flow, so that any condensate that forms flows toward the lowest points;
  • Condensate drains—preferably automatic ones—should be installed at the lowest points;
  • The outlets extend from the top of the main pipe, with a gooseneck bend, so that water flowing along the bottom does not enter the downspouts;
  • Each downspout ends lower than the water supply line for the car, with a drain valve: the water collects there and not in the user's unit;
  • Pipes should be sized generously: a 1-bar pressure drop in the system means the compressor has to operate at 1 bar higher, resulting in approximately 7% higher energy consumption (approximate value).
roomcompressorsloop: each outlet receives air from two sidesand the pressure drops only slightly even at the far end of the departmentoutletFloor PlanElevation of a section (exaggerated slope)flow · gradient 1–2%FRLUsersFRLusergooseneck inletdrain on the downpipeautomatic drain at the lowest point
Figure 42.5 · Above: a plan view of the looped network. Below: a sectional view showing the slope toward the low point, gooseneck fittings, downspouts with drainage, and an FRL unit before the service connection.

The FRL Treatment Group

Before reaching each machine, the air passes through the treatment unit, known as an FRL—an acronym for its three components:

  • F, filter: circulates air through a glass (the centrifuge separates the water droplets) and passes it through a porous cartridge that traps impurities, typically ranging from 5 to 40 µm; the collected condensate is drained manually or via an automatic drain;
  • R, pressure regulator: reduces the supply pressure to the level required by the machine and keeps it constant even if the supply pressure fluctuates; it is adjusted using the knob and read on the pressure gauge. The downstream pressure can only be equal to or lower than the upstream pressure;
  • L, lubricator: sprays a very fine mist of oil into the air. Today, many components are lubricated for life, so the lubricator is no longer installed; but be careful: if a system has been lubricated, it must remain so at all times, because the oil has washed away the assembly grease.
filter withcondensate drainregulatorwith pressure gaugelubricatorknobFRLDetailed symbolsymbolsimplified symbol
Figure 42.6 · The FRL assembly: on the left, its construction; on the right, the symbols for the three components (filter with drain, regulator with pressure gauge, and lubricator) and the simplified symbol.

The FRL unit is often equipped with a padlockable isolation valve, which shuts off the air supply and vents the system for maintenance, and a soft-start valve, which gradually fills the system at startup to prevent the cylinders from jarring suddenly.

42.5 Actuators: Cylinders

The cylinder It converts air pressure into force and linear motion. It is made of a reed (the tube, made of aluminum or steel), closed at both ends by two publications, with a piston sealed and connected to the stem, which exits the front end through a guide bushing and a scrape it off which keeps dirt out. The travel is the distance the rod travels from fully retracted to fully extended.

  • Single-acting cylinder: Air enters through a single port and pushes the piston in one direction; a spring returns it. It uses half as much air, but the spring reduces the force and limits the travel (usually up to about 100 mm). It is used for small clamping applications, ejectors, and marking.
  • Double-acting cylinder: two ports, one per chamber; air pushes the piston in both directions. It is the most commonly used cylinder: it provides force in both the forward and return travels and is capable of long travels.
rear mountfront mountbarrel (tube)piston sealstie rodrear cylinder headrear shock absorbermagnet (for sensors)shock absorber sleeveguide bushingrod scraperrodrear chamberfront chamber
Figure 42.7 · Cross-section of a double-acting cylinder: cylinder barrel, end caps, tie rods, piston with seals and solenoid, piston rod, bushing, rod scraper, and the two end-of-travel shock absorbers.

At the end of its travel, the piston reaches speeds of up to 1 m/s and would slam into the cylinder head. The pneumatic shock absorber slows it down: over the last 15–30 mm, a sleeve on the piston rod enters a seal in the cylinder head and closes the main air outlet; the air remaining in the chamber can escape only through a small passage regulated by a screw; it compresses and acts as a cushion. It is adjusted by tightening the screw until the piston reaches the bottom without impact, but without bouncing. For large masses and high speeds, external hydraulic dampers are added.

The ring magnet in the piston is used by the magnetic sensors mounted outside the barrel, which signal the piston’s position without physical contact (paragraph 42.13). Standardized cylinders (ISO 15552 for bores from 32 to 320 mm, ISO 6432 for mini-cylinders from 8 to 25 mm) have the same mounting interfaces and overall dimensions across all manufacturers and can be interchanged without modifying the machine drawing.

simple effectspring-returnsingle-actingspring-loaded, air-returndouble-actingdouble-acting withadjustable shock absorbersdouble-actingthrough-rodrodlesswith external carriage
Figure 42.8 · Cylinder symbols. The rectangle represents the cylinder barrel, the thick line the piston, and the bar the piston rod; the diagonal arrows indicate adjustable shock absorbers.

42.6 Cylinder Force and Bore Selection

The air presses against the entire surface of the piston, so the force is equal to the pressure multiplied by the area. During the extension stroke (when the rod extends), the area is the entire surface area of the piston, with diameter D (the bore). During the pull stroke (when the rod retracts), the air presses against the circular ring around the rod: the area of the rod, with diameter d, must be subtracted from the area of the piston. Therefore, at the same pressure, a cylinder always exerts less force during the pull stroke than during the push stroke.

FThrust: The air presses against the entire pistonA = π · D² / 4FTension: the rod reduces its cross-sectional areaA − a = π · (D² − d²) / 4
Figure 42.9 · In compression, the air presses against the entire circle of diameter D; in tension, it presses only against the rim, because the center is occupied by the stem.
Theoretical and Actual Force of a Cylinder
Fthrust = p · A Ftraction = p · (A − a) A = π · D²4 a = π · d²4
Factual = η · Ftheoretical simple effect: F = η · p · A − Fspring
F force in N · p relative pressure in N/mm² (6 bar = 0.6 N/mm²) · A piston area in mm² · a cross-sectional area of the stem in mm² · D bore and d shaft diameter in mm · η efficiency, which takes into account seal friction: approximately 0.85 to 0.9 (approximate value; lower for small bores and low pressures) · Fspring spring force at end of travel in N

Relative pressure is used, not absolute pressure: on the other side of the piston, there is still atmospheric pressure (the exhaust chamber is open to the atmosphere), and the two atmospheric pressures cancel each other out.

Example 42.5 · Thrust and Tension in a Ø50 Cylinder

Double-acting cylinder with a bore of 50 mm and a rod diameter of 20 mm, operated at 6 bar. Calculate the theoretical and actual forces with η = 0.9.

p = 6 bar = 0.6 N/mm²
A = π · 50² / 4 = 1963.5 mm²; a = π · 20² / 4 = 314.2 mm²; A − a = 1649.3 mm²
theoretical thrust = 0.6 × 1963.5 = 1178 N (the same result as in Example 2.5)
Theoretical tensile force = 0.6 × 1649.3 = 990 N
actual values: 0.9 × 1178 = 1060 N in compression; 0.9 × 990 = 891 N in tension
Compression force approximately 1,060 N, tensile force approximately 890 N: under tensile load, the cylinder loses 16% of its force due to the piston rod
Example 42.6 · Simple spring-mass system

A single-acting cylinder with a diameter of 32 and operating at 6 bar has a spring that exerts a force of 40 N at the end of its travel. Given that η = 0.9, what force does it exert at the end of the travel?

A = π · 32² / 4 = 804.2 mm²
F = 0,9 · 0,6 · 804,2 − 40 = 434,3 − 40 = 394 N
Approximately 394 N; on the return stroke, the only force available is that of the spring

Choosing the Bore Diameter

To select the cylinder, start by determining the required force, divide it by the efficiency and the pressure, and calculate the theoretical bore; then choose the next larger standard bore. It’s a good idea to leave a margin: system pressure can drop when many machines are drawing power at the same time, and a cylinder that also has to accelerate a load needs extra force.

Required bore diameter
D = √(4 · Fπ · p · η) Required pressure: p = FA · η
D bore diameter in mm · F required force in N · p pressure in N/mm² · η efficiency · A effective area in mm² (for tension, A − a)
Bore D (mm)Stem d (mm)Area A (cm²)Theoretical thrust (N)Theoretical Traction (N)Thrust with η = 0.85 (N)
1261,13685158
1662,01121104103
2083,14188158160
25104,91295247250
32128,04483415410
401612,57754633641
502019,6311789901001
632031,17187016821590
802550,27301627212564
1002578,54471244184006
12532122,72736368816259
16040201,0612 06411 31010 254
20040314,1618 85018 09616 022

Table 42.1 · Standard bores and forces at 6 bar, calculated using F = p · A. The rods are those typical of the standard series (ISO 6432 up to 25, ISO 15552 from 32 onward): the exact values should always be taken from the manufacturer’s catalog.

Example 42.7 · What size cylinder is needed to exert a force of 2000 N?

A cylinder must push a workpiece with a force of 2000 N; the system provides 6 bar; efficiency is 0.85.

D = √(4 · 2000 / (3,1416 · 0,6 · 0,85)) = √(8000 / 1,602) = √4993 = 70.7 mm
The standard bore mentioned above is 80 mm: actual thrust = 0.85 × 0.6 × 5026.5 = 2564 N
Ø80 cylinder: 2,564 N, with a 28% margin over the required force
Example 42.8 · A clamp designed for tensile loads

A clamping bracket must exert a force of 1500 N at 6 bar and with η = 0.85. Is a Ø63 cylinder with a Ø20 piston rod sufficient?

Ø63: A − a = 3117.2 − 314.2 = 2803.0 mm² → F = 0.85 · 0.6 · 2803.0 = 1430 N < 1500 N
Ø80, stem 25: A − a = 5026.5 − 490.9 = 4535.7 mm² → F = 0.85 · 0.6 · 4535.7 = 2313 N
The Ø63 would be sufficient for thrust (1590 N), but not for tension: the Ø80 is needed
Example 42.9 · What pressure should the cylinder be set to?

A Ø40 cylinder must apply a force of 500 N to a delicate workpiece—no more. To what value should the regulator be set? (η = 0.9)

A = π · 40² / 4 = 1256.6 mm²
p = 500 / (1256.6 × 0.9) = 0.442 N/mm² = 4.42 bar
Regulator set to approximately 4.4 bar: the force of a cylinder is adjusted by the pressure

42.7 Air Consumption

With each travel, the cylinder fills with air at operating pressure, and during the return travel, that air is discharged into the atmosphere. The consumption per cycle is therefore the volume of the filled chambers, multiplied by the compression ratio, to express it in liters of free air—that is, in the same unit as the compressor’s flow rate.

Air consumption of a cylinder
double effect: Qcycle = (A + A − a) · c · r simple effect: Qcycle = A · c · r
Q = Qcycle · n r = prel + 1,0131,013
Qcycle Consumption per cycle (round trip) in liters of free air · A, a piston and rod areas in dm² (or in mm², divided by 1,000,000) · c traveling in dm · r compression ratio · Q Free air flow rate in L/min · n cycles per minute. The volume of the tubing between the valve and the cylinder is added in the same way; for short lengths of tubing, a margin is taken into account.
Example 42.10 · Power Consumption of a Double-Acting Cylinder

Cylinder Ø50, rod Ø20, travels 200 mm, 6 bar, 10 cycles per minute. Calculate the consumption per cycle and per minute in free air.

volume in the forward stroke = 1963.5 × 200 = 392,700 mm³ = 0.3927 L
return volume = 1649.3 × 200 = 329,867 mm³ = 0.3299 L
total volume after compression = 0.7226 L; r = 7.013 / 1.013 = 6.923
Qcycle = 0.7226 × 6.923 = 5.00 L of free air
Q = 5.00 × 10 = 50.0 L/min
5 liters of free air per cycle, 50 L/min at 10 cycles per minute
Example 42.11 · Consumption of a simple bill

A single-acting ejector with a diameter of 32, travel of 50 mm, and a pressure of 6 bar operates at 30 cycles per minute.

volume = 804.2 × 50 = 40,212 mm³ = 0.0402 L
Qcycle = 0,0402 · 6,923 = 0,278 L ; Q = 0.278 × 30 = 8.35 L/min
Approximately 8.4 L/min of free air
Example 42.12 · What kind of compressor is needed for a department?

A department has 4 cylinders, as in Example 42.10, 2 ejectors, as in Example 42.11, and a blow-off gun that consumes 200 L/min but is used, on average, for one-quarter of the time. Add 30% to account for losses and future expansion.

cylinders: 4 × 50.0 = 200.0 L/min; ejectors: 2 × 8.35 = 16.7 L/min; blowing: 200 × 0.25 = 50.0 L/min
total = 266.7 L/min; with a margin of: 266.7 × 1.3 = 346.7 L/min
We need a compressor that delivers at least 350 L/min of free air at line pressure (delivered flow rate, not the theoretical intake flow rate).

42.8 Speed, Control, and Other Actuators

The speed of the cylinder

The piston speed depends on how much air can enter one chamber and, above all, exit the other: on the pressure, the load, the valve flow rate, and the lengths and diameters of the tubes. Standard cylinders operate at speeds between approximately 0.1 and 1 m/s; below 0.05 m/s, the motion becomes jerky (the friction between the seals causes them to separate and reattach, a phenomenon known as stick-slip).

Required flow rate for a given velocity
Q = A · v · r
Q free air flow rate in L/s (with A in dm² and v in dm/s) · A effective piston area · v piston speed · r compression ratio. This is used to select the size of the valve and the pipes.
Example 42.13 · How Much Air Do You Need to Go Fast?

The Ø50 cylinder in Example 42.10 must travel 200 mm in the forward direction in 0.8 s. What is the free air flow rate that the valve must provide?

v = 200 / 0.8 = 250 mm/s = 0.25 m/s
A · v = 1963.5 · 250 = 490,875 mm³/s = 0.491 L/s of compressed air
Q = 0.491 × 6.923 = 3.40 L/s = 204 L/min of free air
Approximately 204 L/min during travel: much higher than the average flow rate of 50 L/min, and the valve is selected based on this peak flow rate

The adjustment: restricted exhaust

To slow down a cylinder, a unidirectional flow regulator is used: an adjustable orifice with a check valve connected in parallel. In one direction, the air flows freely through the check valve; in the other, it is forced to pass through the throttle. In double-acting cylinders, the exhaust is throttled: air enters freely into the driving chamber and exits, slowed down, through the exhaust chamber. Thus, the piston remains held between two cushions of pressurized air and moves smoothly even if the load changes. By throttling the intake, however, the piston moves in jerks; this is done only in single-acting cylinders and in a few special cases.

The regulators are mounted as close as possible to the cylinder, often screwed directly into its ports; to ensure a quick return, a quick-release valve is added to the cylinder port, which vents the air there without allowing it to flow all the way back to the valve. The complete diagram is shown in Figure 42.17.

Other Actuators (Overview)

  • Rodless cylinders: The piston drives an external carriage through a slot using sealing strips or a magnetic coupling. For the same travel, they take up half the space and are suitable for travels measured in meters.
  • Rotary actuators: vane-type or piston-type with rack and pinion; they provide limited rotation (90°, 180°, 360°) and are used to rotate workpieces, open valves, and tilt.
  • Parallel or angular collets: two or three jaws driven by a piston, for manipulators and robots (Chapter 51).
  • Suction cups and vacuum generators: The Venturi-effect generator directs compressed air through a nozzle that narrows; the air accelerates, the pressure drops, and it draws in air through the side port, creating a vacuum in the suction cup. It has no moving parts and is used for sheet metal, glass, and cardboard.
rodless cylinderlong travels, compact designrotary actuatorrack and pinion: from 90° to 360°parallel collet1dischargevacuum generatorand suction cup
Figure 42.10 · Other pneumatic actuators: rodless cylinder, rack-and-pinion rotary actuator, parallel collet, Venturi-effect vacuum generator with suction cup.
Example 42.14 · How much weight can a suction cup lift?

A Ø40 suction cup operates at a vacuum of −0.6 bar. Given a safety factor of 2 for vertical lifting, what is the maximum weight of the workpiece?

F = 0.06 N/mm² · π · 40² / 4 = 0.06 · 1256.6 = 75.4 N
Fadmitted = 75.4 / 2 = 37.7 N → mass = 37.7 / 9.81 = 3.84 kg
Approximately 3.8 kg; for oily, porous, or heavily accelerated workpieces, increase the safety margin or the number of suction cups

The peak load on the stem

A long, thin rod under thrust may bend sideways before breaking: this is the peak load discussed in Section 10.12. For pneumatic cylinders, this problem arises with long travels—over 500–1,000 mm—and articulated mounts. The verification is performed using Euler’s formula, with the rod fully extended, where the free length at the inflection point depends on the mountings.

Example 42.15 · The rod of a Ø100 long-travel cylinder

A Ø100 cylinder with a Ø25 steel rod operates at 6 bar. It is articulated at both ends, and when the rod is fully extended, the free bending length is 1100 mm. With a safety factor of 4, will it hold up?

i = 25 / 4 = 6.25 mm → λ = 1100 / 6.25 = 176 > 100: Euler's formula holds
I = π · 25⁴ / 64 = 19,175 mm⁴
Fcr = 3.1416² × 210,000 × 19,175 / 1,100² = 32,845 N; Fam = 32,845 / 4 = 8,211 N
Theoretical thrust: 0.6 × 7854 = 4712 N < 8211 N
It holds up: with the low forces involved in pneumatic systems, peak loads rarely cause problems; with hydraulic systems, where forces are much higher, this check must always be performed (example 10.21)

42.9 Distributor Valves

Distributor valves (or distributors) determine where the air goes: they open, close, and divert the flow between the connections. Inside, they have a spool or spool valve that moves between two or three positions. Drawings do not show the valve’s internal structure, but only its function, using a symbol in accordance with ISO 1219.

How to Read the Symbol

  • Each square represents a valve position: two squares, two positions;
  • Inside each square, the arrows indicate open passages and the direction of airflow; the T-shaped symbol indicates a closed passage;
  • The tubes are attached to the square representing the rest position (the position the valve is in when not actuated): to visualize the other position, slide the symbol until the other square takes the place of the first one;
  • The moves are the valid attacks, which are counted on the rest square;
  • On either side are the controls: the control shown next to a square moves the valve to that position.

A valve is designated by two numbers: routes / locations. A 5/2 has 5 lines and 2 positions. The bindings are numbered: 1 nutrition, 2 e 4 uses, 3 e 5 outlets; the control commands correspond to the numbers of the two connections they link (14 connects 1 to 4, 12 connects 1 to 2, 10 closes 1). On older diagrams, you’ll also find the letters P (supply), A and B (outputs), and R and S (drains).

51342abworking positionrest position (connected to the tubes)Control: solenoid(solenoid valve)spring return1Supply (P)2 · 4outlets, to the cylinder (A, B)3 · 5Outlets (R, S)12 · 14pilot lines: 14 for 1→4, 12 for 1→2Squares = positions (here 2)Connections on the rest square = channels (here 5)5/2-way monostable valve
Figure 42.11 · Anatomy of a 5/2-way monostable, electrically operated, spring-return valve.

The Commands

Controls are divided into muscular (button, lever, pedal: operated by the operator), mechanical (taster, roller, unidirectional roller: operated by a part of the machine, such as a cam on the stem), spring-loaded (return the valve to its rest position), pneumatic (an air signal moves the spool), and electric (a solenoid, i.e., a coil that attracts an iron core). In larger solenoid valves, the coil does not move the spool directly: it opens a small pilot valve that sends air to move it (servo-piloted control).

A valve with one control signal and a spring is monostable: once the control signal ends, it returns to its rest position. A valve with two opposing control signals and no spring is bistable: it remains in the last position it was commanded to be in even after the signal ends—that is, it acts as a memory.

muscleGeneral Muscle Painbuttonleverlever with lock(stays where you leave it)pedalmechanical and spring-loadedsensorrollerunidirectional roller(triggers in one direction only)springpneumatic and electricpneumatic controlsolenoid (coil)electropneumatic(coil + servo)
Figure 42.12 · Control symbols drawn on the side of a valve body.

The Most Commonly Used Valves

  • 2/2: Opens or closes a passage, like a faucet;
  • 3/2 NC (normally closed): in the closed position, port 2 is connected to the exhaust port 3 and the supply port 1 is closed; when actuated, it directs air from port 1 to port 2. This is the valve used for single-acting cylinders and signals (buttons, limit switches);
  • 3/2 NO (normally open): the opposite—it allows air to flow when not activated and blocks it when activated;
  • 4/2 and 5/2: These are controlled by double-acting cylinders, which send air to one chamber while venting the other. The 5/2 has two separate exhaust ports, so the exhaust flow rate can be adjusted (using adjustable silencers), and the ports are larger; it is the most commonly used type.
122/2 NCnormally closed1323/2 NCnormally closed1323/2 NOnormally open13424/2for double-acting cylinders513425/2two separate exhausts
Figure 42.13 · Spring-return push-button valves. The tubes are always connected to the right-hand square, the rest position.

The 5/3 valves have a third central position, which the spool moves to when no control signal is active (it is usually centered by two springs). The central position determines what happens to the cylinder when the control signal is removed, for example, in an emergency:

  • closed centers: all ports are closed; the cylinder stops where it is (but the compressible air allows it to give slightly under load, and leaks cause it to slip over time);
  • open-center pressure systems: fluid is supplied to both chambers; in a single-rod cylinder, the thrust prevails and the rod extends smoothly;
  • Exhaust ports: Both chambers are vented; the cylinder can be moved by hand without air pressure; this is useful for freeing a workpiece or an operator.
51342Closed centersthe cylinder stops and remains blocked51342open centers under pressureair in both chambers51342unloaded centersthe cylinder remains freeThe two springs return the slide to the center when no solenoid is energized.
Figure 42.14 · Spring-centered 5/3-way solenoid valves: only the central square changes.

42.10 Other Valves

  • Check valve: allows air to flow in one direction and blocks it in the other; in the symbol, the ball rests against the V-shaped seat when air pushes in the wrong direction.
  • Selector valve (logical function OR, "or"): It has two inputs and one output; air comes out of the output if it enters through one of the inputs o On the other hand, the inner ball seals the inlet without pressure, so air does not escape from the button when it is not pressed.
  • Simultaneity valve (AND function, “and”): Air is discharged only if it is supplied from both inputs.
  • One-way flow regulator: adjustable orifice valve with check valve, for regulating flow in one direction only.
  • Quick-release valve: mounted on the cylinder connection; when the control valve opens, it creates a large passage to the atmosphere; the cylinder empties immediately, and the return is faster.
  • Pneumatic timer (overview): A signal fills a small reservoir through a restrictor; when the pressure in the reservoir has risen sufficiently, it actuates a 3/2-way valve. The delay is adjusted using the restrictor, ranging from fractions of a second to a few tens of seconds. Today, delays are almost always implemented using a PLC (Chapter 49).
No returngoes only upwardno returnspring-loadedselector (OR)air from one inlet or the othersimultaneous (AND)air only from both inputs together22flow regulatorunidirectionaladjustable orificein both directions2 (cylinder)1 (valve)3quick exhaustair escapes immediately, near the cylindertimerthrottle valve + reservoir + 3/2
Figure 42.15 · Block, flow, and time-delay valves. The check valve allows free flow upward and restricts flow downward.

42.11 Basic Circuits

In pneumatic diagrams, components are arranged from bottom to top, following the flow of energy: the power supply at the bottom, the valves that provide signals (buttons, limit switches) above, then the power valves, and the actuators at the top. Components are drawn in their rest position; control lines are drawn as dashed lines.

Direct and Indirect Control

In direct control, the operator operates the valve that sends air to the cylinder: simple, but the button valve must be as large as the cylinder requires and be located close to it. In indirect control, the button is a small signal valve that controls a larger power valve mounted near the cylinder: the button can be located farther away, on the panel, connected by thin tubing. All real machines use indirect control.

A132Direct Control3/2-way NC buttonA13212132power valvePilot-operated 3/2 NCSignal valveIndirect control
Figure 42.16 · Single-acting cylinder: on the left, controlled directly by a 3/2-way button valve; on the right, by a pilot-operated 3/2-way button valve, which is in turn controlled by a 3/2-way button valve.

The double-acting cylinder is controlled by a 5/2-way valve. With a monostable 5/2-way button valve, the piston rod extends only as long as the button is held down. With a bistable 5/2-way valve controlled by two buttons, S1 extends the piston rod and S2 retracts it, and the valve retains the last command even when the buttons are released. Figure 42.17 on the right also shows the two flow regulators installed to restrict the exhaust flow.

A51342Direct control with 5/2A513421412132132S1: outS2: onregulatorsexhaustrestrictedIndirect control, memory, and regulated speed
Figure 42.17 · On the left, direct control using a 5/2-way button valve. On the right, the bistable 5/2-way valve controlled by S1 and S2, along with unidirectional flow regulators: air enters freely through the check valves and exits through a restricted orifice.

Two-point control and two-hand control

To control a cylinder from two different locations, install two buttons and an OR selector valve: pressing either one is sufficient. To ensure that the operator keeps both hands away from the hazardous area, a simultaneous-action valve (AND) is used: the cylinder activates only if both buttons are pressed at the same time. Note: This is only the basic principle; a true two-hand safety control system must also verify that the buttons are pressed within half a second of each other and that they are released before a new cycle begins, and this is achieved using certified modules (Chapter 51).

A132132S1S2selectorFrom two points: selector (OR)A132132S1S2simultaneityTwo-handed: Simultaneity (AND)
Figure 42.18 · On the left, the cylinder extends when S1 or S2 is pressed; on the right, it extends only when S1 and S2 are pressed together.

Automatic return, semi-automatic cycle, and automatic cycle

To allow the rod to retract automatically when it reaches the end of its stroke, a limit valve is used: a 3/2 NC roller valve, mounted where the cam contacts the rod. The positions are designated by the lowercase letter corresponding to the cylinder: a0 is the end-of-stroke position with the piston rod retracted, and a1 is the end-of-stroke position with the piston rod extended. In the semi-automatic cycle, the operator presses the start button; the piston rod extends, touches a1—which activates pin 12 of the bistable relay—and the piston rod retracts: one cycle per press of the button.

In the automatic cycle, the cycle start is triggered by a lever valve with a hold mechanism (it remains actuated) connected in series with the a0 limit switch: when the stem has retracted and touches a0, if the gear is engaged, a new cycle begins, and so on until the lever is moved. The two valves in series perform an AND function without the need for a simultaneity valve.

a0a1A513421412132a1132StartSemi-automatic cyclea0a1A513421412132a1132132a0DriveAutomatic cycle
Figure 42.19 · On the left is the semi-automatic cycle: the start button extends the piston rod, and limit switch a1 retracts it. On the right, the automatic cycle: the lever-operated gear with a hold mechanism, connected in series with a0, restarts the cycle every time the piston rod retracts.

42.12 Two-cylinder sequences

The Stride-Step Diagram

When there is more than one cylinder, the cycle is described using the following sequence: the cylinder letter followed by + (rod extends) or − (rod retracts). For example, A+ B+ A− B− means: A extends, then B extends, then A retracts, then B retracts. The stroke-stroke diagram illustrates this: the horizontal axis shows the travels of the cycle, and the vertical axis shows the position of each cylinder (0 = retracted, 1 = extended).

12345 = 1A01B01A+ B+ A− B−12345 = 1A01B01A+ B+ B− A−Step 3: b1 controls B−, but a1 still holds B+No blocking signal
Figure 42.20 · Stroke-step diagrams. On the left, a sequence with no problems; on the right, at step 3, the B− command still finds the B+ command active.

The sequence A+ B+ A− B−: no blocking signal

Each movement is controlled by the limit switch that signals the end of the previous movement: A+ at startup and b0 (in series), B+ with a1, A− with b1, B− with a0. Referring to the diagram, verify that when a signal commands a movement, the opposite signal on the same valve has already disappeared: for example, when b1 commands A−, the A+ signal (start and b0) is no longer present, because B is off. The sequence operates using the direct circuit shown in Figure 42.21.

a0a1Ab0b1B513421412513421412132132132132132b0b1a1a0StartA+ ← start · b0A− ← b1B+ ← a1B− ← a0
Figure 42.21 · Sequence A+ B+ A− B−: two cylinders, two 5/2-way double-acting valves, and four roller limit switches. The limit switches a0 and b0, which are in their rest positions, are actuated by the cams of the retracted piston rods.
Example 42.16 · Find the blocking signals for A+ B+ B− A−

Using the same method, the sequence A+ B+ B− A− would be controlled as follows: A+ at startup, B+ with a1, B− with b1, A− with b0. Let’s check step by step to ensure that the two commands do not arrive simultaneously at the two bistable circuits.

Step 1, A+: B is on, so b0 is activated and sends air to pin 12 of A (A−), while the start signal sends air to pin 14 (A+): b0 is blocking
Step 2, B+: a1 controls B+, and there is no other command on B: that's fine
Step 3, B−: b1 controls B−, but A is still off, and a1 still holds the B+ control: a1 is blocking
Step 4, A−: b0 controls A− and the start signal has been released: OK
Two inhibiting signals, b0 at step 1 and a1 at step 3: the bistable circuit with two identical control signals remains stationary, and the cycle hangs

A signal is blocking when it remains active even during the stroke in which the same valve is supposed to move in the opposite direction. To spot this, simply look at the stroke-cycle diagram: a cylinder that makes two consecutive movements (such as B+ and immediately B−) without another cylinder moving in between almost always indicates a problem. There are three solutions:

  • unidirectional roller limit switch: the roller engages only when the piston rod moves in one direction and produces a brief pulse instead of a continuous signal; it works, but the limit switch must be mounted slightly before the end of the travel and no longer indicates with certainty where the cylinder is located;
  • memory valve: a 3/2 or 5/2 bistable valve that supplies power to the latching limit switch only during the part of the cycle when it is needed, and “turns it off” during the rest of the cycle;
  • Cascade method: This is the systematic way to use memory valves, and it works for any sequence.

The Waterfall Method

The sequence is divided into groups so that each letter appears only once in each group: A+ B+ / B− A− forms two groups, I and II. Each group has its own air line, and only one line is pressurized at a time; the memory valves—which number one less than the number of groups (in this case, a single 5/2-way bistable valve)—switch them. The limit switches are powered by their respective group’s line, so a limit switch that remains activated when the cycle is stopped does not cause any issues when its line is de-energized. The rules:

  • The first move of each group is directed directly by the group's line (Line I → A+, Line II → B−);
  • Subsequent movements within the same group are controlled by the limit switch of the previous movement, which is powered by that line (a1, from line I, controls B+);
  • The last limit switch in a group does not control a cylinder but rather the memory, which is passed on to the next group (b1 switches to II; b0, from line II, then controls A−);
  • The last limit switch of the cycle (a0), connected in series with the cycle start switch, resets the memory to Group I and restarts the cycle.
a0a1Ab0b1B513421412513421412III513421412memory132to B 14 (B+)a1132from memory 12b1132a A 12 (A−)b0132132a0Start
Figure 42.22 · Circuit for A+, B+, B−, A−. Line I (red) controls A+ and powers a1 and b1; Line II (blue) controls B− and powers b0 and the limit switch a0, in series with the starter. For clarity, the limit switch outputs are labeled with the control signal they are connected to.

Let’s follow the cycle. At rest, line II is energized (the memory is at rest on 2): b0 is active but drives A−, which has already been done, so it doesn’t cause any issues. The start button is pressed: with a0 activated, the memory switches to I. Line I controls A+; A turns on and activates a1, which (powered by I) controls B+; B turns on and activates b1, which switches the memory to II. Now line I is off: a1 no longer controls anything, and the block from step 3 has disappeared. Line II controls B−; B returns to its normal state and activates b0, which controls A−; A returns to its normal state and activates a0, ready for the next cycle. The trade-off of this cascade is a slight delay at each group change, because the line must fill up; with many groups, series-connected solenoids slow down the cycle, and for more than three or four cylinders, an electropneumatic system with a PLC is preferred.

42.13 Electropneumatics

In modern machines, the power system remains pneumatic (cylinders and valves), while the control system is electrical: signals are sent from sensors and electrical buttons and are transmitted to the solenoid coils via relays or, almost always, a PLC.

  • Monostable solenoid valves (one coil and a spring) return to their rest position when power is cut off; bistable solenoid valves (two coils) remain in their current position. They typically operate at 24 V DC and are mounted in a bank on a single base—the valve island—connected to the PLC via a single cable or a fieldbus network.
  • Magnetic sensors are mounted in the barrel groove and detect the piston’s magnet through the wall: they are either reed switches (a blade that closes when near the magnet) or electronic Hall-effect or magnetoresistive sensors, with no moving parts. They replace roller limit switches and do not require cams. We will discuss them in Chapter 47.
  • The sequence is written in the PLC program (Chapter 49), where the interlock signals are handled using program registers instead of additional valves.
1A1B1 (a0)1B2 (a1)513421Y11Y2+24 V0 VS1 Start1B11Y1: A+1B21Y2: A−24 V DC wiring diagram
Figure 42.23 · Semi-automatic cycle in an electropneumatic system. Pressing S1 with the piston rod retracted (1B1 closed) energizes 1Y1, causing the piston rod to extend; when it reaches the end of its stroke, 1B2 energizes 1Y2, causing the piston rod to retract.

The electrical diagram in Figure 42.23 corresponds to the pneumatic diagram on the left side of Figure 42.19: S1 and 1B1, connected in series, form an AND gate between the start signal and the retracted spool; 1B2 acts as the limit switch a1. The designations follow the standard: 1A is the cylinder, 1B1 and 1B2 are its sensors, 1Y1 and 1Y2 are the solenoid valve coils, and S1 is the button.

42.14 Safety, Cost Savings, and Maintenance

Safety

  • Before working on a system, close the isolation valve and bleed the air: a cylinder with trapped air (for example, one with a 5/3 closed-center valve) can move suddenly when a hose is disconnected.
  • A hose that comes loose under pressure can whip around and cause injury: Use appropriate fillets and, for large hoses, safety clamps.
  • Never point the air gun at people or at the skin; use safety nozzles that limit the outlet pressure when cleaning workpieces. Blown-off chips can fly into your eyes: always wear safety glasses.
  • Valve exhausts always have a muffler: a noisy workshop is a workshop that’s dangerous to your hearing.
  • At startup, the soft-start valve prevents the cylinders from activating all at once; if there is no air, the machine must move to a safe position (Chapter 51).

Air Leaks and Energy Savings

Compressed air is the most expensive form of energy in a workshop: to produce one cubic meter of free air at 7 bar, a good compressor consumes about 0.10–0.12 kWh of electricity, and almost all of it is converted into heat. In a poorly maintained system, leaks (loose fillets, cut hoses, worn gaskets, left-open air guns) can easily account for 20–30% of output. You can’t see a leak—you hear it when the machines are shut down, in the silence at the end of the shift.

Example 42.17 · How much does a 1-mm hole cost over the course of a year?

From a 1-mm hole at 6 bar, approximately 60 L/min of free air escapes (approximate value: depends on the shape of the hole). The network remains pressurized 16 hours a day for 250 days. At 0.12 kWh per cubic meter and an energy cost of 0.25 €/kWh, how much does the leak cost per year? (All figures are approximate and chosen for illustrative purposes.)

hours per year = 16 × 250 = 4,000 h
air loss = 60 L/min × 60 min/h × 4,000 h = 14,400,000 L = 14,400 m³
energy = 14,400 × 0.12 = 1,728 kWh
cost = 1,728 × 0.25 = 432 €
More than €400 a year for a hole you can't see: about ten leaks like that cost more than a new compressor

The rules for saving money are simple: locate and repair leaks (even using ultrasonic detectors), operate at the lowest pressure necessary, shut off the air supply to idle machines using a valve controlled from the control panel, use cylinders of the correct size, avoid continuous air discharge, and recover heat from the compressor to heat water or the workshop.

Maintenance

ComponentWhat do you do?When (indicative)
Tank and Automatic DrainsCheck that condensation is draining; empty it by hand if necessaryEvery day or every week
FRL Group FiltersDrain the glass; replace the cartridge when the pressure drop increasesEvery week / every 6–12 months
Lubricator (if any)Top off with the oil specified by the manufacturer; check for leaksEvery week
CompressorAir filter, oil, separator, belts, temperatureAccording to the working hours listed in the manual
DryerClean the condenser; check the dew pointEvery month
Netting and FilletsLeak Detection When Machinery Is Shut DownEvery 3–6 months
CylindersClean the stem, check the stem scraper, clearances, and shock absorbers; replace the seals if there is a leakMachine Maintenance
MufflersReplace any clogged ones, as they slow down the cylindersWhen a movement slows down
🔧
Has the cylinder become sluggish? Before disassembling it, check the following in order: the pressure on the FRL unit’s pressure gauge, a clogged filter, the flow regulators (has anyone shut them off?), the muffler on the exhaust, and a crushed hose. The cylinder itself is almost always the last culprit.

42.15 The Formulas in This Chapter

WhatFormula
Absolute pressurepass = prel + 1.013 bar
Boyle's Lawp1 · V1 = p2 · V2 (absolute pressures)
Compression Ratior = (prel + 1.013) / 1.013; Vfree = Vcompressed · r
Usable air volume of a tankVfree = Vtank · (pmax − pmin) / 1.013
Theoretical thrust forceF = p · A ; A = π · D² / 4
Theoretical tensile forceF = p · (A − a) ; a = π · d² / 4
Real forceFreale = η · Ftheoretical (η ≈ 0.85–0.9); single-effect: F = η · p · A − Fspring
Required bore diameterD = √(4 · F / (π · p · η))
Consumption per cycle (double-acting)Qcycle = (A + A − a) · c · r
Per-minute usageQ = Qcycle · n
Flow rate at a given velocityQ = A · v · r
Force of a suction cupF = Δp · π · d² / 4

42.16 Exercises

Unless otherwise specified, atmospheric pressure is 1.013 bar and the system operates at 6 bar.

Exercise 1. A pressure gauge reads 4.5 bar. What is the absolute pressure? And what is the relative pressure in psi?
Solution

pass = 4.5 + 1.013 = 5.513 bar. In psi: 4.5 × 14.50 = 65.3 psi.

Exercise 2. 20 L of ambient air is compressed to 5 L at a constant temperature. What relative pressure does it reach?
Solution

p2 = 1.013 × 20 / 5 = 4.052 bar absolute, that is, 4.052 − 1.013 = 3.039 bar relative.

Exercise 3. Calculate the compression ratio at 8 bar. How many liters of free air are there in 2 L of compressed air at that pressure?
Solution

r = 9.013 / 1.013 = 8.897; free air volume = 2 × 8.897 = 17.8 L.

Exercise 4. A 270-liter tank operates at pressures between 9 and 7 bar. If the system consumes 400 L/min and the compressor is shut off, how long will the reserve last?
Solution

Available air = 270 · (9 − 7) / 1.013 = 533 L; time = 533 / 400 = 1.33 min, approximately 80 s.

Exercise 5. Calculate the theoretical thrust and pull of a cylinder with a diameter of 63 and a rod diameter of 20.
Solution

A = π · 63² / 4 = 3117.2 mm²; thrust = 0.6 · 3117.2 = 1870 N. A − a = 3117.2 − 314.2 = 2803.0 mm²; tensile force = 0.6 · 2803.0 = 1682 N.

Exercise 6. A cylinder with a diameter of 40 and a rod with a diameter of 16: actual compressive and tensile forces, with η = 0.85.
Solution

A = 1256.6 mm², a = 201.1 mm². Compressive force = 0.85 · 0.6 · 1256.6 = 641 N; tensile force = 0.85 · 0.6 · (1256.6 − 201.1) = 538 N.

Exercise 7. A thrust of 3,500 N is required with η = 0.85. Which standard bore do you choose?
Solution

D = √(4 · 3500 / (3.1416 · 0.6 · 0.85)) = 93.5 mm: we choose Ø100, which gives 0.85 · 0.6 · 7854 = 4006 N.

Exercise 8. A single-acting cylinder with a diameter of 25 has a spring that exerts a force of 25 N at the end of its travel. What is the force exerted at the end of the travel when η = 0.9?
Solution

A = 490.9 mm²; F = 0.9 × 0.6 × 490.9 − 25 = 265.1 − 25 = 240 N.

Exercise 9. Cylinder Ø40, rod Ø16, travels 150 mm, 12 cycles per minute. Calculate the consumption of free air in liters per minute.
Solution

Volume per cycle = (1256.6 + 1055.6) × 150 = 346,832 mm³ = 0.3468 L; for 6.923 = 2.40 L of free air per cycle; for 12 cycles = 28.8 L/min.

Exercise 10. A cylinder with a diameter of 32 must travel a distance of 100 mm in 0.5 s. What must be the free air flow rate of the valve during this travel?
Solution

v = 100 / 0.5 = 200 mm/s; A · v = 804.2 · 200 = 160,850 mm³/s = 0.161 L/s; multiplied by 6.923 = 1.11 L/s = 66.8 L/min.

Exercise 11. What diameter must a suction cup have to lift a 2-kg workpiece vertically at −0.6 bar with a safety factor of 2?
Solution

Required force = 2 · 9.81 · 2 = 39.24 N; area = 39.24 / 0.06 = 654 mm²; d = √(4 × 654 / 3.1416) = 28.9 mm: Choose a suction cup with a diameter of 30 mm or larger.

Exercise 12. A cylinder with a diameter of 80 has a rod with a diameter of 20, hinged at both ends, with a free length of 800 mm. With a safety factor of 4, does the peak load allow for full stroke at 6 bar?
Solution

i = 20 / 4 = 5 mm, λ = 800 / 5 = 160 (Euler's formula applies); I = π · 20⁴ / 64 = 7854 mm⁴; Fcr = 3.1416² · 210,000 · 7,854 / 800² = 25,435 N; Fam = 6,359 N, which is 3,016 N greater than the thrust: that’s fine.

Exercise 13. Describe the connections of a 5/3 closed-center valve in its three positions.
Solution

Left position (command 14): 1 with 4, 2 with 3, 5 closed. Center: all five attacks closed. Right position (command 12): 1 with 2, 4 with 5, 3 closed.

Exercise 14. Divide the sequence A+ B+ B− C+ C− A− into groups using the cascade method. How many memory valves are needed?
Solution

Groups: I = A+ B+; II = B− C+; III = C− A− (each letter appears only once in each group). Three groups, so 3 − 1 = 2 memory valves.

Exercise 15. A system has three leaks, each of approximately 60 L/min. The system is under pressure for 2,000 hours per year; air costs 0.12 kWh/m³ and electricity costs 0.25 €/kWh. How much is spent on these leaks in a year?
Solution

Air loss = 3 × 60 × 60 × 2,000 = 21,600,000 L = 21,600 m³; energy = 21,600 × 0.12 = 2,592 kWh; cost = 2,592 × 0.25 = 648 €.